PPDSM-721D-MTCP PoE Serial-to-Ethernet Device Server, Modbus Gateway, 6 DI/7 DO
Metal-cased programmable serial-to-Ethernet device server with RS-232 and RS-485 ports, 6 digital inputs, 7 open-collector outputs, PoE and a Modbus TCP to RTU/ASCII gateway.
- Serial RS-232 and RS-485 ports bridged to Ethernet, with Virtual COM support for Windows PCs
- Modbus TCP to RTU/ASCII gateway for SCADA and HMI communication
- IEEE 802.3af, Class 1 Power over Ethernet, or 12 to 48 VDC terminal block power
- 6 wet-contact digital inputs with latched and counter functions
- 7 open-collector sink (NPN) digital outputs rated 30 VDC and 100 mA max.
- Programmable device server with MiniOS7 and Xserver programming structure
€262.00 per piece
| 1–9 pcs | €262.00 | |
|---|---|---|
| 10–30 pcs | €255.00 | −3 % |
| 31+ pcs | €249.00 | −5 % |
Product information "PPDSM-721D-MTCP PoE Serial-to-Ethernet Device Server, Modbus Gateway, 6 DI/7 DO"
PPDSM-721D-MTCP links an RS-232 device and an RS-485 device to an Ethernet network, so existing serial equipment can be integrated without replacing it. Its built-in Modbus TCP to RTU/ASCII gateway lets SCADA and HMI systems that speak Modbus TCP reach serial devices. The unit is powered either over Ethernet using IEEE 802.3af, Class 1 PoE or from a +12 ~ 48 VDC terminal block.
The unit combines 6 wet-contact digital inputs and 7 open-collector sink (NPN) digital outputs with a programmable device server. It supports latched digital input and counter functions. The VxComm utility maps the serial ports to virtual COM ports on 32/64-bit Windows 7 SP1, 10, 2012 and 2016. A built-in MiniOS7 and an Xserver programming structure support custom Ethernet applications.
The metal housing is intended for wall mounting and is rated for operation from -25 ~ +75 °C. The ordering code includes the CA-0910 cable. Check the terminal block wiring and the input and output electrical limits against your field devices before installation.
Applications
- Factory automation
- Building automation
- Home automation
| Product type: | Serial-to-Ethernet device server |
|---|---|
| Interface: | Ethernet, RS-232, RS-485 |
| Protocol: | Modbus TCP |
| Digital inputs: | 6 |
| Digital outputs: | 7 |
| Ports: | 1x RS-232, 1x RS-485 |
| PoE: | IEEE 802.3af, Class 1 |
| Power input: | +12 ~ 48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | Wall mounting |
| Housing: | Metal |
Specifications
| CPU Module | |
|---|---|
| CPU | 80186-80 MHz or compatible |
| EEPROM | 16 KB; Data retention: 40 years; 1,000,000 erase/write cycles. |
| Flash | 512 KB ; Erase unit is one sector (64 KB); 100,000 erase/write cycles |
| SRAM | 512 KB |
| Watchdog Timer | Yes |
| LED Indicators | |
| Status | 1 x Power/PoE 5 x digit 7 Segment |
| Digital Input | |
| Channels | 6 |
| Type | Wet Contact |
| Sink/Source (NPN/PNP) | Source, Common Ground |
| ON Voltage Level | +3.5 ~ +30 V |
| OFF Voltage Level | +1 V max. |
| Digital Output | |
| Channels | 7 |
| Type | Open Collector |
| Sink/Source (NPN/PNP) | Sink (NPN) |
| Load Voltage | 30 VDC, max. |
| Load Current | 100 mA, max. |
| Ethernet | |
| Ports | 10/100 Base-TX, RJ-45 port (Auto-negotiating, auto MDI/MDI-X, LED indicator) |
| COM Ports | |
| Ports | 1 x 5-wire RS-232 1 x RS-485 |
| Baud Rate | 115200 bps Max. |
| Bias Resistor | Yes, 1 KΩ |
| Parity | None, Even, Odd, Mark, Space None parity is required when using 8 data bits and 2 stop bits on COM1/COM2. |
| Data Bit | 7, 8: for COM1 and COM2 |
| Stop Bit | 1, 2: for COM1 ~ COM2 |
| Node Address | 254 (max.) |
| Power | |
| Consumption | 2.9 W |
| Powered from PoE | IEEE 802.3af, Class 1 |
| Powered from Terminal Block | +12 ~ 48 VDC |
| Mechanical | |
| Casing | Metal |
| Dimensions (mm) | 102 mm x 29 mm x 125 mm (W x L x H) |
| Installation | Wall mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +80 °C |
| Humidity | 5 ~ 90% RH, non-condensing |
Specifications as published by the manufacturer. Subject to change.