tGW-718i-T Modbus TCP to RTU/ASCII Gateway, 1-port Isolated RS-232/422/485
Compact Modbus TCP to RTU/ASCII gateway with one isolated RS-232/422/485 port and terminal block power input, for bringing serial Modbus devices onto Ethernet.
- Modbus TCP to RTU/ASCII protocol conversion with master and slave support on both sides
- One 3-wire serial port selectable as RS-232, RS-422 or RS-485, with 3000 VDC signal isolation
- Read-cache for faster Modbus TCP/UDP responses and reduced load on the serial bus
- Up to 32 TCP connections (masters) per serial port
- Serial settings up to 115200 bps, with parity, 5 to 8 data bits and 1 or 2 stop bits
- Static IP or DHCP network configuration, configurable via built-in HTTP web server
€167.00 per piece
| 1-9 pcs | €167.00 | |
|---|---|---|
| 10-30 pcs | €159.00 | −5 % |
| 31+ pcs | €151.00 | −10 % |
Product information "tGW-718i-T Modbus TCP to RTU/ASCII Gateway, 1-port Isolated RS-232/422/485"
The tGW-718i-T bridges Modbus TCP hosts and serial Modbus RTU or ASCII devices, letting a supervisory system on Ethernet poll field instruments fitted with RS-232, RS-422 or RS-485 interfaces without rewiring them. Its single serial port is signal-isolated to 3000 VDC, which helps protect the serial side in electrically noisy installations.
Each serial port accepts up to 32 TCP masters, and a read-cache stores previous requests and responses so that repeated queries from several HMI or SCADA masters are answered from memory. This reduces traffic on the RS-485 bus and shortens response times on the Ethernet side. Automatic RS-485 direction control removes the need to manage transceiver direction in the application.
The gateway supports Modbus TCP/UDP and Modbus RTU/ASCII in both master and slave roles, and can be configured through its built-in web server or located on the network with UDP Search. It is powered from a terminal block at +12 ~ 48 VDC and mounts on a DIN rail in a compact plastic housing.
Applications
- Factory automation
- Building and home automation
- Remote diagnosis and management
- Solar monitoring
| Product type: | Gateway |
|---|---|
| Interface: | Ethernet, RS-232/422/485 |
| Protocol: | Modbus TCP |
| Ports: | 1 serial, 1 Ethernet |
| Isolation: | 3000 VDC |
| Power input: | +12 ~ 48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
| Housing: | Plastic |
Specifications
| CPU Module | |
|---|---|
| CPU | 32-bit ARM |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-pin RJ-45 x 1, (Auto-negotiating, Auto-MDI/MDIX, LED indicator) |
| COM Ports | |
| Ports | 1 x 3-wire RS-232/RS-485/RS-422 (3000VDC Signal Isolation) |
| Baud Rate | 115200 bps Max. |
| Bias Resistor | Yes, 1 KΩ |
| Parity | None, Odd, Even, Mark, Space |
| Data Bit | 5, 6, 7, 8 |
| Stop Bit | 1, 2 |
| Node Address | 254 (max.) |
| Power | |
| Consumption | 0.07 A @ 24 VDC |
| Powered from Terminal Block | +12 ~ 48 VDC |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 52 mm x 95 mm x 27 mm (W x H x D) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, non-condensing |
Specifications as published by the manufacturer. Subject to change.