tGW-718i Modbus TCP to RTU/ASCII Gateway, PoE, 1-port Isolated RS-232/422/485
Compact DIN-rail Modbus TCP/UDP to RTU/ASCII gateway with PoE and one 3000 VDC isolated RS-232/422/485 serial port, supporting up to 32 TCP masters per serial port.
- Modbus TCP/UDP master and slave to Modbus RTU/ASCII master and slave conversion
- One isolated RS-232/RS-485/RS-422 serial port with 3000 VDC signal isolation and 115200 bps maximum baud rate
- Up to 32 TCP connections (masters) per serial port
- Read-cache for faster Modbus TCP/UDP responses and reduced serial bus loading
- PoE IEEE 802.3af, Class 1, or +12 ~ 48 VDC terminal block power input
- Automatic RS-485 direction control, 1 KΩ bias resistor and UDP Search device discovery
€167.00 per piece
| 1-9 pcs | €167.00 | |
|---|---|---|
| 10-30 pcs | €159.00 | −5 % |
| 31+ pcs | €151.00 | −10 % |
Product information "tGW-718i Modbus TCP to RTU/ASCII Gateway, PoE, 1-port Isolated RS-232/422/485"
The tGW-718i CR is a compact gateway that lets Modbus TCP/UDP masters communicate with serial Modbus RTU or ASCII devices over Ethernet, removing the cable-length limits of legacy serial networks. It suits engineers who need to bring serial-only instruments, drives or controllers onto a TCP/IP network without adding a computer or server to the field.
The unit offers one isolated RS-232, RS-422 or RS-485 port and a 10/100 Base-TX Ethernet port with IEEE 802.3af Class 1 Power over Ethernet. It can also be powered from a +12 ~ 48 VDC terminal block. A read-cache stores previous requests and responses, so repeated requests to the same slave device are answered immediately, which reduces RS-485 bus loading and improves response times. The device can also be configured for pair-connection or serial-bridge operation, routing data over TCP/IP between two serial Modbus devices.
This variant ships with a DC-jack to 2-wire power cable, 0.3 M. Configuration is handled through a built-in HTTP web server, and the unit supports static IP or DHCP addressing and UDP-based device discovery.
Applications
- Factory automation
- Building and home automation
- Remote diagnosis and management
- Solar monitoring
| Product type: | Gateway |
|---|---|
| Interface: | RS-232/422/485 |
| Protocol: | Modbus TCP |
| Ports: | 1 serial, 1 Ethernet |
| PoE: | IEEE 802.3af, Class 1 |
| Isolation: | 3000 VDC |
| Power input: | +12 ~ 48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
| Housing: | Plastic |
Specifications
| CPU Module | |
|---|---|
| CPU | 32-bit ARM |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-pin RJ-45 x 1, (Auto-negotiating, Auto-MDI/MDIX, LED indicator) PoE (IEEE 802.3af, Class 1) |
| COM Ports | |
| Ports | 1 x 3-wire RS-232/RS-485/RS-422 (3000VDC Signal Isolation) |
| Baud Rate | 115200 bps Max. |
| Bias Resistor | Yes, 1 KΩ |
| Parity | None, Odd, Even, Mark, Space |
| Data Bit | 5, 6, 7, 8 |
| Stop Bit | 1, 2 |
| Node Address | 254 (max.) |
| Power | |
| Consumption | 0.07 A @ 24 VDC |
| Powered from PoE | IEEE 802.3af, Class 1 |
| Powered from Terminal Block | +12 ~ 48 VDC |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 52 mm x 95 mm x 27 mm (W x H x D) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, non-condensing |
Specifications as published by the manufacturer. Subject to change.
Downloads
Login