WLS-RS300 Wireless Locating System Receiver with Relay & T&H Sensor
Ceiling-mounted 2.4GHz locating receiver that converts location data to 400MHz for extended range, with relay alarm output and built-in temperature and humidity sensing.
- Converts 2.4GHz location data to 400MHz to extend wireless transmission distance without added wiring
- Receives 2.4GHz location data from WLS-T01, WLS-T02 and WLS-T11 tags
- 16 RF channels across 2.4GHz and 400MHz bands
- 1 x SPDT (Form C) relay output for an alarm device
- Built-in buzzer with remote enable function
- Onboard temperature and humidity sensor with 0 to +50°C temperature range
181,00 € per piece
| 1–9 pcs | 181,00 € | |
|---|---|---|
| 10–30 pcs | 175,00 € | −3 % |
| 31+ pcs | 172,00 € | −5 % |
Informations sur le produit "WLS-RS300 Wireless Locating System Receiver with Relay & T&H Sensor"
The WLS-RS300 CR is a fixed-position 2.4GHz wireless receiver for the WLS locating system. It collects location data broadcast by WLS-T01, WLS-T02 and WLS-T11 tags, and it can also act as a router that converts 2.4GHz traffic to 400MHz. The 400MHz link covers longer distances without additional cabling between communication points.
The receiver includes a relay output for driving an alarm device, a built-in buzzer with remote enable, and an onboard temperature and humidity sensor. Parameters are set with DIP and rotary switches. The WLS software on a PC can poll location data through the RFU-400 transparent function and calculate relative positions.
This ordering code is the ceiling-mounted variant, which the manufacturer lists for Asia only. It suits item tracking, personnel movement monitoring and factory zone management. The product carries FCC, RoHS and WEEE certification marks as listed in the source data.
Applications
- Item tracking
- Personnel movement monitoring
- Factory regional management
| Product type: | Wireless locating system receiver |
|---|---|
| Interface: | 2.4GHz / 400MHz wireless |
| Relay outputs: | 1 (SPDT, Form C) |
| Power input: | 100 VAC ~ 240 VAC |
| Operating temperature: | 0 ~ +50 °C |
| Mounting: | Ceiling / surface |
| Housing: | Ø150 x 53 mm |
Specifications
| Alarm and Event | |
|---|---|
| Alarm Triggers | Min. 85dBA(Typical 92)@10cm |
| LED Indicators | |
| Status | 1 x Power 1 x 400MHz Transmitted status 1 x 2.4GHz Received status |
| Temperature Measurement | |
| Range | 0°C ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Humidity Measurement | |
| Range | 0.1% RH |
| Resolution | ±5% RH |
| Accuracy | 0 ~100% RH |
| RF | |
| Antenna | 2.4GHz:2.4GHz - 3dBi PCB directional antenna 400MHz:429MHz – 5dBi PCB directional antenna |
| Channels | 16 |
| Frequency Band | 2.4GHz: 2.4GHz 400MHz: Channel 0~9- 429.8125 MHz to 429.9250 MHz; Channel A~F- 429.1750 MHz to 429.2375 MHz |
| Modulation | 2.4GHz:OQPSK (Offset Quadrature Phase-shift Keying) |
| Spread Spectrum | 2.4GHz:DSSS (Direct-Sequence Spread Spectrum) |
| Transmission Power | 2.4GHz:16±1dBm (Default) / 17dBm (Max.) 400MHz:19dBm (Default / Max.) |
| No. of Nodes | 2.4GHz:90 (Max., Tag Tx interval is 3 seconds) |
| Transmission Distance (LoS) | 2.4GHz:100m (Default) 400MHz:160m(Default) |
| Relay Output | |
| Channels | 1 (SPDT, Form C) |
| Power | |
| Input Range | 100 VAC ~ 240VAC |
| Consumption | 5 W Max. |
| Mechanical | |
| Dimensions (mm) | Ø150 x 53 (Ø x H) |
| Installation | Ceiling /surface mounted |
| Environment | |
| Operating Temperature | 0°C ~ +50°C |
| Storage Temperature | -30°C ~ +75°C |
| Humidity | 10 ~ 90% RH(Non-condensing) |
Specifications as published by the manufacturer. Subject to change.