PROFIBUS
The PROFI-5017 is a PROFIBUS DP-V0 slave remote I/O module that brings eight differential analog voltage inputs onto a PROFIBUS network. Input ranges of ±10 V, ±5 V, ±2.5 V and ±1.25 V with an accuracy of ±0.1 of FSR suit a range of signal levels, and each channel is isolated from the logic side at 2500 Vrms.Integration is straightforward: the module is configured through its GSD file in any PROFIBUS configurator, and the station address (0 to 126) is set by rotary switches or an SSA telegram. The transmission rate is detected automatically across the listed baud rates, from 9.6 kbit/s up to 12 Mbit/s.Isolation and protection features include 3000 VDC DC-to-DC isolation, a high-speed iCoupler on the network side and 4 kV ESD protection on each terminal. The module is rated for an operating temperature of -25 ~ +75 °C and mounts on a DIN rail, with a power consumption of 3 W.ApplicationsIndustrial automationFactory automationProcess automation
The PROFI-5017C is a PROFIBUS DP-V0 slave module that brings eight differential current inputs onto a PROFIBUS network. Each input accepts 0 ~ 20mA signals with an accuracy of +/- 0.2% of FSR, making it suited to连接 standard process transmitters in distributed control layouts.Isolation is provided on several levels: 2500Vrms between the field and logic sides, 3000 VDC on the PROFIBUS side, and high speed iCoupler isolation on the network interface. Each terminal carries 4KV ESD protection, which helps the module tolerate harsh plant environments.Node addressing is set by rotary switches or an SSA telegram, and the transmission rate is detected automatically across the listed baud rates up to 12 M. Integration is handled through the GSD file in any PROFIBUS configurator, and the module mounts on a DIN-rail for operation between -25 ~ +75℃.ApplicationsIndustrial automationFactory automationProcess automation
PROFIBUS Remote I/O Module (10-channel Thermocouple Input with High Voltage Protection). Includes a DB-1820 daughter board.
PROFI-5024 CR is a PROFIBUS DP-V0 slave that adds four isolated analogue outputs to a PROFIBUS network. Each channel supports ±10 V, 0~20 mA or 4~20 mA ranges, so it can drive valves, drives and other analogue actuators from a single fieldbus node.The module is isolated for robust installation. It provides 3000 VDC DC-to-DC isolation and 3750 Vrms bus-to-logic isolation, along with high-speed iCoupler network isolation and 4 kV ESD protection on each terminal. Stated accuracy is ±0.1% of FSR for voltage output and ±0.2% of FSR for current output.Address range 0~126, set by rotary switches or SSA telegramTransmission rate detected automatically across 9.6 k to 12 M baudI/O configuration performed with the GSD file in any PROFIBUS configuratorThe unit is designed for DIN-rail mounting and runs from a 4 W consumption figure, with an operating range of -25 ~ +75℃ and storage from -30 ~ +80 ℃.ApplicationsIndustrial automationFactory automationProcess automation
The PROFI-5045 CR is a PROFIBUS DP-V0 slave module that adds 24 digital outputs to a PROFIBUS network. The outputs are sink-type with a common ground, and the field side accepts a load voltage of +10 to +40 V, with a maximum load current of 650 mA and short-circuit protection.Isolation is built in at several points: 3750 Vrms between field and logic, 3000 VDC on the PROFIBUS side for DC-to-DC, and 2500 Vrms for bus-to-logic, supported by high-speed iCoupler network isolation. Each terminal has its own 4 kV ESD protection.Addressing is set on rotary switches from 0 to 99 and the transmission rate is detected automatically. I/O configuration is carried out using the GSD file in any PROFIBUS configurator. The module draws 1 W, mounts on DIN-rail and operates from -25 to +75 °C.ApplicationsIndustrial automationFactory automationProcess automation
PROFI-5050 is a PROFIBUS DP-V0 slave remote I/O module that brings 16 digital inputs and 8 digital outputs onto a PROFIBUS network. The inputs accept sink or source wiring, and the outputs are sink type, so the module suits a wide range of field devices such as switches, sensors and small loads.Addressing is set on rotary switches across the range 0 to 99, and the transmission rate is detected automatically across the PROFIBUS rates from 9.6 kbit/s up to 12 Mbit/s. The I/O configuration is handled through the GSD file, so the module can be added to any PROFIBUS configurator without custom tooling.For electrically noisy plants, the PROFIBUS side is isolated to 3000 VDC and the network is protected by high-speed iCoupler isolation. Each terminal has 4 kV ESD protection. The module is DIN-rail mounted and rated for an operating range of -25 to +75 ℃.ApplicationsIndustrial automationFactory automationProcess automation
The PROFI-5051 adds 24 isolated digital inputs to a PROFIBUS DP network as a DP-V0 slave. Each channel accepts sink or source wiring and has a 3750 Vrms isolation rating, which suits field signals that need to be kept apart from the control side.Setup is straightforward. The transmission rate is detected automatically, the station address is set from 0 to 99 using rotary switches, and the I/O configuration is loaded from the GSD file, so the module can be added to any PROFIBUS configurator. Supported baud rates run from 9.6 k up to 12 M.On-state input range of +10 to +50 V, with off-state level up to +4 VOperating temperature of -25 to +75 °C, storage of -30 to +80 °C, 10 to 90% RH non-condensingDIN-rail mounting, 91 x 128 x 52 mm (W x L x H), power consumption of 1 WApplicationsIndustrial automationFactory automationProcess automation
The PROFI-5052 CR adds 12 isolated digital inputs to a PROFIBUS DP network as a DP-V0 slave. It suits engineers who need discrete field signals brought onto a PROFIBUS bus without building custom interface hardware. Each input works in sink or source mode and is isolated from the others.Integration is straightforward. The module is configured through its GSD file in any PROFIBUS configurator, the transmission rate is detected automatically, and the node address is set from 0 to 99 using rotary switches. Input isolation is rated at 5000Vrms, and high-speed iCoupler isolation separates the network side from the logic.Status is shown by PWR and RUN LEDs. The module draws 1 W, has an operating range of -25 ~ +75℃, and is intended for DIN-rail installation in factory and process automation systems.ApplicationsIndustrial automationFactory automationProcess automation
The PROFI-5053 CR is a PROFIBUS DP slave that brings 24 dry contact digital inputs onto a PROFIBUS network. It suits engineers who need a compact, DIN-rail mounted input point for distributed machine or plant signals without adding a separate PLC input card.Integration is straightforward. The module is set up from its GSD file in any PROFIBUS configurator, and the node address is chosen between 0 and 99 using rotary switches. The transmission rate is detected automatically across the listed PROFIBUS baud rates, up to 12 M.For electrically noisy or mixed-potential installations, the bus side is isolated, with 3000 VDC DC-to-DC and 2500 Vrms bus-to-logic isolation, and each terminal carries 4KV ESD protection. The unit is rated for operation from -25 ~ +75℃.ApplicationsIndustrial automationFactory automationProcess automation
The PROFI-5055 CR is a PROFIBUS DP-V0 slave remote I/O module that brings eight isolated digital inputs and eight isolated digital outputs onto a PROFIBUS network. It suits engineers who need discrete field signals connected to a DP master without building custom wiring or logic at the bus level.Each digital input accepts sink or source wiring and is isolated from the others, with an on-voltage range of +10 to +50 V. The eight digital outputs are sink type, with a load voltage of +10 to +40 V and a maximum load current of 650 mA without short-circuit protection. Both I/O groups are rated for 3750 Vrms isolation.Commissioning is straightforward: the transmission rate is detected automatically, the node address is set from 0 to 99 using rotary switches, and the I/O configuration is loaded from the GSD file. The module is designed for DIN-rail mounting and operates from -25 to +75 °C.ApplicationsIndustrial automationFactory automationProcess automation
PROFI-5060 CR is a PROFIBUS DP-V0 slave I/O module that brings eight digital inputs and four relay outputs onto a PROFIBUS network. It suits engineers who need simple discrete I/O on a fieldbus segment without a dedicated controller at the remote location.The digital inputs accept sink or source wiring and are isolated from each other, with 3750Vrms isolation. The four relay outputs are Form C contacts rated 0.6A@125VAC and 2A@30VDC. Bus-side isolation is 3000 VDC for DC-to-DC and 2500 Vrms for bus-to-logic, and each terminal has 4kV ESD protection.Address set from 0 to 99 with rotary switchesBaud rate detected automatically across the listed PROFIBUS rates, up to 12 MModule configuration done with the GSD file in any PROFIBUS configuratorThe module draws 1 W and mounts on a DIN-rail. It is rated for an operating temperature of -25 ~ +75℃, with a storage range of -30 ~ +80 ℃.ApplicationsIndustrial automationFactory automationProcess automation
The PROFI-8155-G CR is a PROFIBUS DP slave unit that adds one I/O slot to a PROFIBUS network. The slot accepts I-8K, I-87K Low Profile and I-87K High Profile I/O modules, so a single unit can be fitted with the signal type a machine or process section needs without changing the network design.Network integration is straightforward. The unit supports DP-V0 and DP-V1 read/write slave operation, detects the transmission rate automatically and takes its station address from rotary switches. Modules are selected and arranged through the GSD file, so no separate configuration tool is required for setup.For maintenance, I-87K High Profile modules can be hot-swapped while the unit is running. The PROFIBUS side is isolated and protected against ESD, making the unit suitable for DIN-rail mounting in industrial control cabinets across a range of automation and process environments.ApplicationsIndustrial automationFactory automationProcess automation
PROFI-8255-G turns a pair of ICP DAS I/O modules into a PROFIBUS DP slave. It accepts I-8K, I-87K Low Profile and I-87K High Profile modules in its two slots, so a single unit can be fitted with the I/O mix a machine needs. The unit supports DP-V0 and DP-V1 with read/write access, and its address is set with rotary switches across 0 to 126.Configuration is handled entirely from the GSD file, so the I/O modules are chosen and mapped in the PROFIBUS master's configuration tool without any separate setting software. The transmission rate is detected automatically. I-87K High Profile modules can be hot-swapped while the unit is in service, which simplifies maintenance on running lines.For electrically noisy plants, the unit provides a 3000 VDC isolation barrier on the PROFIBUS side, 2500 Vrms bus-to-logic isolation via High Speed iCoupler, and 4 kV ESD protection on each terminal. It is rated for an operating temperature of -25 to +75 °C and mounts on a DIN rail or a wall.ApplicationsIndustrial automationFactory automationProcess automation
PROFI-8455-G is a PROFIBUS DP-V0 slave unit that brings four expansion slots to a PROFIBUS network. Each slot accepts I-8K, I-87K Low Profile or I-87K High Profile I/O modules, so one unit can be built around the mix of signals a machine or process section requires.Configuration is handled through the GSD file, so the I/O modules fitted to the unit can be selected and set up in the PROFIBUS master without a separate vendor tool. The transmission rate is detected automatically, and the station address is set from 0 to 126 using rotary switches.Electrical isolation and protection are built in. The PROFIBUS side has 3000 VDC DC isolation, the network side uses High Speed iCoupler isolation, and each terminal is rated for 4KV ESD protection. I-87K High Profile modules can be hot-swapped. The unit is CE, FCC, RoHS and WEEE listed and is suited to factory and process automation installations.ApplicationsIndustrial automationFactory automationProcess automation
PROFI-8855-G CR is a PROFIBUS DP-V0 slave that turns a rack of eight I/O slots into a remote I/O station. It accepts I-8k High Profile and I-87K High Profile modules, so one unit can cover a mix of digital, analogue and other signal types on a single PROFIBUS segment.Engineers will value the configuration workflow. I/O modules are set up through the GSD file, so the station can be defined without a separate vendor setting tool. The transmission rate is detected automatically, and the station address is chosen with rotary switches anywhere from 0 to 126.For installations that need electrical robustness, the unit provides 3000 VDC isolation on the PROFIBUS side and High Speed iCoupler network isolation. Hot-swap is available for I-87K High Profile modules, and each terminal has 4KV ESD protection. The unit mounts on a DIN rail or on a wall.ApplicationsIndustrial automationFactory automationProcess automation