Passer au contenu principal Passer à la recherche Passer à la navigation principale

ECAT-2601 EtherCAT MainDevice Gateway for Modbus and OPC UA

Informations sur le produit "ECAT-2601 EtherCAT MainDevice Gateway for Modbus and OPC UA"

The ECAT-2601 CR is a gateway that connects an EtherCAT network with Modbus and OPC UA systems. Its built-in EtherCAT MainDevice drives EtherCAT SubDevices directly, and a shared data exchange buffer makes their I/O data available to Modbus masters over Modbus TCP and Modbus RTU (slave).

Engineers will value that it connects to SubDevice PDO without requiring an ESI file and supports third-party EtherCAT SubDevices. Free Run mode is supported, the minimum cycle time is 125us, and it reconnects to SubDevices within 10 seconds after power-on. User-defined SDO startup entries can be set, and configuration is handled through the built-in web interface over HTTP/HTTPS.

An OPC UA Server in the firmware lets standard OPC UA clients connect without custom development, covering machine-to-machine communication as well as links to SCADA systems and cloud platforms. The ordering code ECAT-2601 CR denotes the RoHS-compliant version, and the unit mounts on DIN-rail.

Applications

  • Machine-to-machine data exchange between EtherCAT and Modbus systems
  • Vertical integration of EtherCAT machines with SCADA systems
  • Connecting EtherCAT machines to cloud platforms via OPC UA
  • Integrating third-party EtherCAT SubDevices into Modbus or OPC UA networks
Product type: Gateway
Interface: EtherCAT, Ethernet, RS-422/485
Protocol: EtherCAT, Modbus RTU, Modbus TCP, OPC UA
PoE: IEEE 802.3af, Class 2
Power input: +12 ~ 48 VDC
Operating temperature: -25 ~ +75 °C
Mounting: DIN-rail
Housing: Plastic

Specifications

Software
Function• Web Interface for Configuration
Ethernet
PortsRJ-45 x 3
2 x Distance between Stations: Max. 100 m (100BASE-TX)
1 x PoE (IEEE 802.3af, Class 2)
ProtocolModbus TCP, Modbus TCP/TLS, Modbus UDP, OPC UA, SNTP, HTTP/HTTPS, IPv4, IPv6
COM Ports
Ports1 x 422/485
ProtocolModbus RTU (Slave)
EtherCAT
PortsRJ-45 x 1
Distance between Stations: Max. 100 m (100BASE-TX)
Data Transfer Medium: Ethernet/EtherCAT Cable (Min. CAT 5e)
Cycle Time0.125 ~ 32ms
Distributed ClocksYes
Power
Consumption0.22 A @ 24 VDC
Powered from PoEIEEE 802.3af, Class 2
Powered from Terminal Block+12 ~ 48 VDC
Mechanical
CasingPlastic
Dimensions (mm)119 x 31 x 157 (W x L x H)
InstallationDIN-Rail
Environment
Operating Temperature-25 ~ +75 °C
Storage Temperature-30 ~ +80 °C
Humidity10 ~ 90% RH, Non-condensing

Specifications as published by the manufacturer. Subject to change.

0 sur 0 évaluations

Note moyenne de 0 sur 5 étoiles

Laissez une évaluation !

Partagez avec d'autres clients votre avis sur le produit.