CL-222-E PM1/PM2.5/PM10/CO2 Data Logger Module, RS-485 and Ethernet PoE
Environmental data logger for PM1/PM2.5/PM10, CO2, temperature, humidity and dew point, with up to 450,000 time-stamped records and RS-485 and Ethernet/PoE connectivity.
- Records PM1, PM2.5, PM10, CO2, temperature, humidity and dew point
- NDIR CO2 sensor measuring 0 to 9999 ppm
- Stores up to 450,000 records with date and time stamps
- RS-485 and Ethernet/PoE communication interfaces
- DCON, Modbus RTU, Modbus TCP and MQTT protocol support
- Web-based configuration with Windows utility, iOS and Android apps included
€651.00 per piece
| 1-9 pcs | €651.00 | |
|---|---|---|
| 10-30 pcs | €618.00 | −5 % |
| 31+ pcs | €586.00 | −10 % |
Product information "CL-222-E PM1/PM2.5/PM10/CO2 Data Logger Module, RS-485 and Ethernet PoE"
The CL-222-E CR is a data logger module that records particulate matter (PM1, PM2.5 and PM10), CO2, temperature, humidity and dew point, with date and time stamps on every record. Its NDIR CO2 sensor and laser-type particulate measurement suit indoor air quality monitoring where readings need to be stored and reviewed later.
Logged data can be stored in up to 450,000 records and downloaded for analysis. Real-time values can be viewed through the web-based configuration interface, the included Windows utility, or the iOS and Android apps, provided the device and the viewing equipment share the same local network.
The module connects over RS-485 or Ethernet, with PoE supported on the Ethernet port, and speaks DCON, Modbus RTU, Modbus TCP and MQTT. This makes it straightforward to add to an existing HMI, SCADA or IoT architecture. A relay output can drive an alarm or control an indoor air quality device when a monitored value requires action.
Applications
- Transportation of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Blood stations and pharmacies
- Building and energy management
- Warehouse management
- Museums, archives and galleries
- Indoor or underground car park air quality monitoring
| Product type: | Data logger module |
|---|---|
| Interface: | Ethernet, RS-485 |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | 1 |
| Ports: | 2 |
| PoE: | Yes |
| Power input: | +12 ~ +48 VDC |
| Operating temperature: | 0 ~ 50 °C |
| Mounting: | Ceiling/Wall |
| Housing: | Ø 150 x 53 mm |
Specifications
| System | |
|---|---|
| Alarm | PM1/PM2.5/PM10/CO2/RH/Temperature |
| Real Time Clock | Yes |
| Data Logger | Yes, up to 450,000 records |
| Temperature Measurement | |
| Range | -10 ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Life Time | 10 years |
| Humidity Measurement | |
| Range | 0 ~ 100% RH, Non-condensing |
| Resolution | 0.1% RH, Non-condensing |
| Accuracy | ±5% RH, Non-condensing |
| Life Time | 10 years |
| Dew Point | |
| Range | Calculated using temperature and relative humidity |
| Resolution | 0.1°C |
| CO2 Measurement | |
| Range | 0 to 9999 ppm (NDIR) |
| Resolution | 1 ppm |
| Accuracy | ±40 ppm ±3% of measured value |
| Response Time | 120 seconds |
| Warm-up Time | 5 minutes |
| Life Time | 15 years |
| PM1/PM2.5/PM10 Measurement | |
| Range | 0 to 1,000μg/m3 ( Laser Type) |
| Resolution | 1μg/m3 |
| Accuracy | ± 10% of FSR. |
| Response Time | 1 seconds |
| Warm-up Time | 20 seconds |
| Life Time | 5 years, Customer has to replace the filter patch. |
| Particle | |
| Sizes | 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm |
| Relay Output | |
| Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet |
| Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP and MQTT (Ethernet) |
| Power | |
| Consumption | Non-PoE: 2.5 W (Max.) PoE: 2.7 W (Max.) |
| Powered from Terminal Block | +12 ~ +48 VDC |
| Mechanical | |
| Dimensions (mm) | Ø 150 x 53 (Ø x H) |
| Installation | Ceiling Mounting/Wall Mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ 50°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.