CL-222-WF IAQ Data Logger with PM, CO2, Humidity and Wi-Fi
Indoor air quality data logger recording PM1/PM2.5/PM10, CO2, temperature, humidity and dew point, with Ethernet, RS-485 and Wi-Fi, powered by PoE or DC.
- Records PM1/PM2.5/PM10, CO2, temperature, humidity and dew point
- Non-dispersive infrared (NDIR) CO2 sensor, 0 to 9999 ppm range
- Up to 450,000 records with date and time stamps
- RS-485, Ethernet and Wi-Fi interfaces with DCON, Modbus RTU/TCP and MQTT
- Relay output (1 x Form A) for alarm or IAQ device control
- Redundant power: PoE (IEEE 802.3af, Class 1) or +12 ~ +48 VDC
€692.00 per piece
| 1-9 pcs | €692.00 | |
|---|---|---|
| 10-30 pcs | €658.00 | −5 % |
| 31+ pcs | €623.00 | −10 % |
Product information "CL-222-WF IAQ Data Logger with PM, CO2, Humidity and Wi-Fi"
The CL-222-WF CR is an indoor air quality (IAQ) data logger that measures PM1, PM2.5 and PM10 particulate matter, CO2, temperature, humidity and dew point. Readings are stored with date and time stamps, with capacity for up to 450,000 records, which suits long-term monitoring where a verifiable record of conditions is needed.
Connectivity covers RS-485, Ethernet and Wi-Fi (IEEE 802.11b/g/n). DCON and Modbus RTU run over RS-485, Modbus TCP over Ethernet or Wi-Fi, and MQTT over Ethernet, so the logger can feed existing HMI, SCADA or distributed control systems. A relay output can drive alarm or IAQ equipment.
Power can come from PoE (IEEE 802.3af, Class 1) or from a +12 ~ +48 VDC terminal block input. Configuration is done through a web interface, and real-time data can be viewed from the same local network using the supplied software utility, iOS app or Android app. The unit mounts on a ceiling or a wall.
Applications
- Transportation of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Blood stations and pharmacies
- Building and energy management
- Warehouse management
- Museums, archives and galleries
- Indoor or underground parking lot automatic monitoring
| Product type: | Data Logger |
|---|---|
| Interface: | Ethernet, RS-485, Wi-Fi |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | 1 x Form A |
| Ports: | 2 |
| PoE: | Yes (IEEE 802.3af, Class 1) |
| Power input: | PoE or +12 ~ +48 VDC |
| Operating temperature: | 0 ~ 50 °C |
| Mounting: | Ceiling or wall |
Specifications
| System | |
|---|---|
| Security | IP filter (whitelist) and Password (web) |
| Alarm | PM1/PM2.5/PM10/CO2/RH/Temperature |
| Real Time Clock | Yes |
| Data Logger | Yes, up to 450,000 records |
| Temperature Measurement | |
| Range | -10 ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Life Time | 10 years |
| Humidity Measurement | |
| Range | 0 ~ 100% RH, Non-condensing |
| Resolution | 0.1% RH, Non-condensing |
| Accuracy | ±5% RH, Non-condensing |
| Life Time | 10 years |
| Dew Point | |
| Range | Calculated using temperature and relative humidity |
| Resolution | 0.1°C |
| CO2 Measurement | |
| Range | 0 to 9999 ppm (NDIR) |
| Resolution | 1 ppm |
| Accuracy | ±40 ppm ±3% of measured value |
| Response Time | 120 seconds |
| Warm-up Time | 5 minutes |
| Life Time | 15 years |
| PM1/PM2.5/PM10 Measurement | |
| Range | 0 to 1,000μg/m3 ( Laser Type) |
| Resolution | 1μg/m3 |
| Accuracy | ± 10% of FSR. |
| Response Time | 1 seconds |
| Warm-up Time | 20 seconds |
| Life Time | 5 years, Customer has to replace the filter patch. |
| Particle | |
| Sizes | 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm |
| Wi-Fi | |
| Transmission Distance (LoS) | 50 meters (LOS) |
| Standard Supported | IEEE 802.11 b/g/n |
| RX Sensitivity | -95.7 dBm @ 1 DSSS, -74.0 dBm @ 54 OFDM |
| Output Power | 18 dBm @ 1 DSSS, 14.5 dBm @ 54 OFDM |
| Mode | Infrastructure & Limited AP |
| Encryption | WEP, WPA and WPA2 |
| Antenna | 1 dBi (PCB Antenna) |
| Relay Output | |
| Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet |
| Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP(Ethernet, Wi-Fi) and MQTT(Ethernet) |
| Power | |
| Consumption | Non-PoE: 2.4 W (Max.) PoE: 2.6 W (Max.) |
| Powered from Terminal Block | +12 ~ +48 VDC |
| Mechanical | |
| Dimensions (mm) | Ø 150 x 53 (Ø x H) |
| Installation | Ceiling Mounting/Wall Mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ 50°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.