PM-3114-160P-CPS Single-Phase Power Meter, 4-Loop CANopen, 100 A CT
Single-phase 4-loop power meter with CANopen interface and four 100 A clip-on CTs (16 mm aperture, 4 m leads). Measures True RMS power, energy and power factor.
- Four single-phase loops for 1P2W energy analysis, each with a 100 A clip-on CT (16 mm inside diameter, 4 m lead)
- True RMS measurement of voltage, current, active, apparent and reactive power and energy, power factor and frequency
- Current input range 0.1 A ~ 100 A and voltage input range 10 ~ 300 VAC
- W accuracy better than 0.5% (PF=1)
- CANopen interface with DIP switch selectable baud rate: 125 k (default), 250 k, 500 k, 1 M
- Two Form A power relay outputs rated 5 A @ 250 VAC or 5 A @ 30 VDC
€426.00 per piece
| 1-9 pcs | €426.00 | |
|---|---|---|
| 10-30 pcs | €404.00 | −5 % |
| 31+ pcs | €383.00 | −10 % |
Product information "PM-3114-160P-CPS Single-Phase Power Meter, 4-Loop CANopen, 100 A CT"
The PM-3114-160P-CPS CR monitors four single-phase loops at once, giving real-time readings of voltage, current, power and energy for each loop. It is supplied with four 100 A clip-on current transformers with a 16 mm inside diameter and 4 m wire leads, which simplifies installation on existing conductors.
Measurements include True RMS voltage and current, active, apparent and reactive power and energy, power factor and frequency, refreshed every second. Data is available over CANopen, with the baud rate chosen by DIP switch from 125 k (default), 250 k, 500 k and 1 M. Two Form A power relay outputs can drive sirens or lights for alarm signalling.
The meter accepts 10 ~ 300 VAC input and is powered from +12 ~ 48 VDC. Its plastic housing mounts on a DIN rail and it operates from -20 ~ +70 °C, making it suitable for generator monitoring and switchgear distribution systems.
Applications
- Generator monitoring
- Switchgear distribution systems
- Energy management
| Product type: | Power meter |
|---|---|
| Interface: | CANopen |
| Protocol: | CANopen |
| Relay outputs: | 2 |
| Power input: | +12 ~ 48 VDC |
| Operating temperature: | -20 ~ +70 °C |
| Mounting: | DIN-rail |
| Housing: | Plastic |
Specifications
| AC Power Measurement | |
|---|---|
| Wiring | 1P2W-1CT |
| Loops | 1-phase: 4 |
| Input Voltage | 10 ~ 300 V |
| Input Current | PM-3114-100-CPS: CTØ10 mm (0.05 A ~ 60 A) PM-3114-100P-CPS: CTØ10 mm (0.05 A ~ 60 A) PM-3114-160-CPS: CTØ16 mm (0.1 A ~ 100 A) PM-3114-160P-CPS: CTØ16 mm (0.1 A ~ 100 A) PM-3114-240-CPS: CTØ24 mm (0.15 A ~ 200 A) PM-3114-240P-CPS: CTØ24 mm (0.15 A ~ 200 A) |
| Input Frequency | 50/60 Hz |
| W Accuracy | Better than 0.5% (PF=1) |
| Power Parameter Measurement | True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency |
| Data Update Rate | 1 Second |
| Relay Output | |
| Channels | 2 |
| Type | Power Relay |
| Contact Rating | Form A: 5 A @ 250 VAC 5 A @ 30 VDC |
| CANopen | |
| Baud Rate | 125 k (default), 250 k, 500 k, 1 M; DIP Switch Selectable |
| Protocol | CANopen |
| Power | |
| Input Range | +12 ~ 48 VDC |
| Consumption | 2W |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 33 x 127 x 100 (W x L x H) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -20 ~ +70 °C |
| Storage Temperature | -25 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.
Login