ET-7060 Ethernet I/O Module, 6-ch DI and 6-ch Power Relay
Modbus TCP/UDP Ethernet I/O module with 6 wet contact digital inputs (32-bit counters) and 6 form A power relays, for DIN-rail installation.
- 6 wet contact digital input channels (sink/source), each selectable as a 32-bit counter with a 500 Hz frequency rating
- 6 form A (SPST N.O.) power relays rated 5 A @ 250 VAC/24 VDC for resistive loads
- Programmable relay power-on and safe values
- Modbus TCP and Modbus UDP support over one 10/100 Base-TX RJ-45 port
- Built-in web server and web HMI
- Dual watchdog (module and communication, programmable) and I/O pair connection
179,00 EUR per piece
| 1–9 pcs | 179,00 EUR | |
|---|---|---|
| 10–30 pcs | 174,00 EUR | −3 % |
| 31+ pcs | 170,00 EUR | −5 % |
Informații despre produs "ET-7060 Ethernet I/O Module, 6-ch DI and 6-ch Power Relay"
The ET-7060 CR combines six wet contact digital inputs with six form A power relays in a single Ethernet-connected DIN-rail module. Each input can also operate as a 32-bit counter, which suits pulse counting and status monitoring in automation and remote supervision tasks. Relay power-on and safe values are programmable, so outputs can be set to a defined state when the module starts or communication is lost.
Communication is handled over a 10/100 Base-TX RJ-45 port using Modbus TCP or Modbus UDP. A built-in web server and web HMI allow configuration and monitoring through a browser, while dual watchdogs (module and communication, both programmable) help maintain system reliability. Access can be restricted with ID, password and IP filter controls.
Isolation is rated at 3000 VDC for the I/O and 1500 VDC for Ethernet, with no channel-to-channel isolation. When switching inductive loads, fit a flyback diode for DC loads or a metal oxide varistor for AC loads to protect the relay contacts and extend relay life.
Applications
- Building automation
- Factory automation
- Machine automation
- Remote maintenance
- Remote diagnosis
- Testing equipment
| Product type: | Ethernet I/O Module |
|---|---|
| Interface: | Ethernet |
| Protocol: | Modbus TCP, Modbus UDP |
| Digital inputs: | 6 |
| Relay outputs: | 6 |
| Ports: | 1 |
| Isolation: | 3000 VDC (I/O) |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| Software | |
|---|---|
| Built-in Web Server | Yes |
| CPU Module | |
| Watchdog Timer | Module, Communication (Programmable) |
| Isolation | |
| 2-way Isolation | Ethernet: 1500 VDC I/O: 3000 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±2 kV for Power Line |
| ESD (IEC 61000-4-2) | ±4 kV Contact for Each Terminal ±8 kV Air for Random Point |
| Surge (IEC 61000-4-5) | ±0.5 kV for Power Line |
| LED Indicators | |
| Status | Run, Ethernet |
| Digital Input/Counter | |
| Channels | 6 |
| Type | Wet Contact |
| Sink/Source (NPN/PNP) | Sink/Source |
| ON Voltage Level | +10 ~ +50 VDC |
| OFF Voltage Level | +4 VDC (max.) |
| Max. Counts | 4,294,967,295 (32-bit) |
| Frequency | 500 Hz |
| Min. Pulse Width | 1 ms |
| Input Impedance | 10 KΩ |
| Overvoltage Protection | +70 VDC |
| Relay Output | |
| Channels | 6 |
| Type | Power Relay, Form A (SPST N.O.) |
| Contact Rating | 5 A @ 250 VAC/24 VDC (Resistive Load) |
| Operate Time | 10 ms (max.) |
| Release Time | 5 ms (max.) |
| Electrical Endurance | 10^5 ops. |
| Mechanical Endurance | 2 × 10^7 ops. |
| Power on Value | Programmable |
| Safe Value | Programmable |
| Ethernet | |
| Ports | 1 x RJ-45, 10/100 Base-TX |
| Access Control | ID, Password and IP Filter |
| Protocol | Modbus TCP, Modbus UDP |
| Power | |
| Reverse Polarity Protection | Yes |
| Consumption | 2.9 W (max.) |
| Powered from Terminal Block | +10 ~ +30 VDC |
| Mechanical | |
| Dimensions (mm) | 72 x 123 x 35 (W x L x H) |
| Installation | DIN-Rail mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.