Power Meter Concentrator
iWSN data concentrator with PoE Ethernet port. (Asia Only).
iWSN Data Concentrator with 1-port RS-485 and 1-Channel Relay Output. (Asia Only).
PMC-2241M CR gathers readings from ICP DAS Modbus power meters over RS-485 or Ethernet and presents them through a built-in web interface, so energy monitoring can be set up without writing code. It records real-time and historical power data, produces power data statistics reports, and stores logs on a microSD card.Beyond monitoring, the unit runs an IF-THEN-ELSE logic engine for power demand management and can adjust connected Modbus I/O modules according to power status. Alarm messages can be sent via LINE, Telegram or Email, and a Schedule function governs I/O module operation.For integration, the concentrator supports Modbus TCP/RTU, SNMP, FTP and MQTT, and can connect to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar Cloud software. It is intended for engineers building energy management systems that feed SCADA, MES or network management platforms.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower consumption statistics and reportingIntegration with SCADA, MES and network management systems
PMC-2241M-iWSN CR is an iWSN wireless power meter concentrator for energy management in IIoT installations. It collects measurements from ICP DAS iWSN wireless power meters and signal sensing modules through up to three iWSN-200 data concentrators, and presents power consumption, historical data and statistics through a browser-based interface.Power demand control is handled by a built-in IF-THEN-ELSE logic engine, which can act on power meters and I/O modules. Alarm and status messages can be sent by LINE, Telegram or Email, and power data can be logged and sent back as data files.For integration, the unit supports Modbus TCP/RTU for SCADA software, SNMP, MQTT, FTP and CGI, and can connect to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar cloud management software. Note that the iWSN-9603 power meter does not support the 3-minute history data cache function.ApplicationsEnergy measurement, monitoring and managementPower demand managementPower consumption analysis and logging
PMC-2246M CR is a power meter concentrator for energy monitoring and management in Industry 4.0 installations. It gathers readings from ICP DAS Modbus power meters over RS-485 or Ethernet and brings them into one browser-based system, so energy use can be tracked by device and analysed without writing control code.Power data can be shown in real time or as historical records, with statistics reports available from the browser. A microSD card stores power data log files, which are sent back automatically to the back-end system when a network connection is restored. An IF-THEN-ELSE logic engine supports power demand management, and I/O modules can be switched according to power status or a schedule. Alarm messages can be sent via LINE, Telegram, Email or WeChat; the WeChat option requires an Enterprise WeChat account in China.For integration with SCADA, MES, IT, IoT or network management systems, the unit supports Modbus TCP/RTU, SNMP, FTP and MQTT, and can connect to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar Cloud software.ApplicationsEnergy measurement, monitoring and managementPower demand managementEnergy usage analysis and reportingPower consumption monitoring of connected devices with alarm notification
The PMC-2841M CR is a DIN-rail power meter concentrator for energy monitoring systems. It collects data from up to 48 Modbus devices, including ICP DAS Modbus power meters and Modbus I/O modules, over RS-485 and Ethernet, and presents readings in real time or as historical records with power data statistics reports.Configuration is handled entirely through the built-in web interface, so no additional software tool or programming is needed. Control logic is set up on web pages using a built-in IF-THEN-ELSE engine, which supports power demand management and can trigger load shedding where required. Alarms can be sent by LINE, Telegram, WeChat or email.For IoT and cloud integration, the unit supports Modbus TCP and RTU, SNMP, MQTT, FTP and CGI, along with connection to Microsoft Azure, IBM Bluemix and the IoTstar cloud management software. Security options include HTTPS, VPN, SNMP v3, SFTP, FTPS and blacklist/whitelist filtering. The unit carries CE, UKCA, FCC, RoHS and WEEE marks.ApplicationsEnergy measurement, monitoring and management
The PMC-5151-EN CR is a web-based Power Meter Concentrator that is configured, monitored and programmed entirely through a browser. Live and historical power data can be viewed and statistics reports produced without installing any extra software tool, and control logic is edited on built-in web pages.The unit reads Modbus power meters over RS-485 or Ethernet and can also drive Modbus TCP and RTU slave I/O modules, including ICP DAS XW-Board and M-7000 series devices. An IF-THEN-ELSE logic engine, timers and schedules support power demand management, with the option of shedding loads when required.Power data is written to a microSD card, and log files are sent back automatically once a disconnected network is restored. The English-language version has a plastic case, DIN-rail mounting and an operating range of -25 ~ +75 °C.ApplicationsEnergy measurement, monitoring and managementPower demand managementLoad shedding and I/O control based on power status
The PMC-5151-SC CR is a web-based power meter concentrator that gathers power data from ICP DAS Modbus power meters over RS-485 or Ethernet. Configuration, real-time and historical power data, and statistics reports are accessed through a standard browser, so no additional software tool is needed. This ordering code uses the Simplified Chinese web interface and a plastic case.Control logic is set up through web pages rather than programming. A built-in IF-THEN-ELSE logic engine, together with Modbus I/O modules, allows the unit to adjust device operations according to power status, supporting power demand management and load shedding where required. Schedule and timer functions extend control of I/O modules and other devices.Power data can be written to a microSD card for logging, with log files sent back automatically and recovered when a network connection is restored. Alarm messages are delivered by Email, or by SMS when used with the GTM-203M-3GWA modem. Modbus TCP and RTU slave access, FTP and SNMP round out the connectivity options for SCADA and HMI systems.ApplicationsEnergy measurement, monitoring and managementPower demand management and load shedding
PMC-5151-TC CR is a web-based power meter concentrator for energy measurement, monitoring and management. It collects power data from ICP DAS PM Series Modbus meters over RS-485 or Ethernet, and the built-in web server lets engineers view real-time and historical power data and adjust system parameters from a standard browser, without installing additional software.Power demand control is handled on the unit itself. A built-in IF-THEN-ELSE logic engine, timer and schedule functions can switch Modbus I/O modules according to the measured power status, supporting load shedding where required. Data is written to a microSD card and sent back automatically after a network interruption. Alarms can be sent by Email or SMS, with SMS requiring the GTM-203M-3GWA module.For integration, the unit acts as a Modbus TCP/RTU slave, so SCADA software or HMI devices can read live power values. It also supports FTP and SNMP, and the Traditional Chinese edition is identified by its ordering code, which distinguishes it from the -EN and -SC variants.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower data logging and alarm notification
The PMC-5231 CR collects power data from ICP DAS Modbus power meters over RS-485 or Ethernet, then displays, logs and reports it from a standard web browser. It suits energy monitoring projects where engineers want to measure consumption, analyse usage and manage power demand without writing custom code.Beyond metering, the unit can act on what it measures. Its built-in IF-THEN-ELSE logic engine, timer and schedule functions can adjust the operation of Modbus I/O modules according to power status, while alarm messages are sent via LINE, Telegram or Email. Data is written to a microSD card, and log files are sent back to the back-end system and recovered automatically when a network connection is restored.Integration with supervisory and IT systems is handled through Modbus TCP/RTU, SNMP, FTP and MQTT, with connection options for Microsoft Azure, IBM Bluemix and ICP DAS IoTstar Cloud software. Typical deployments combine the concentrator with SCADA, MES or network management platforms.ApplicationsEnergy measurement, monitoring and managementPower demand managementEnergy usage analysis and power statistics reportingIntegration with SCADA, MES and IoT systems
PMC-5231M CR is a power meter concentrator for energy monitoring and power demand management. It gathers readings from ICP DAS Modbus power meters and Modbus I/O modules over RS-485 or Ethernet, and presents real-time and historical power data through a standard web browser. Configuration is done through web pages, so no separate software tool or programming is needed.The built-in IF-THEN-ELSE logic engine lets the unit adjust connected devices according to power status, for example to shed load when demand rises. Alarm messages can be sent by LINE, Telegram or Email, and schedules and timers can control I/O modules. Power data is logged to a microSD card and sent back automatically to the management centre once a disconnected network is restored.For system integration, the concentrator supports Modbus TCP and Modbus RTU, SNMP, FTP and MQTT, and can connect to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar cloud platforms. This suits links to SCADA, MES, IT, IoT and network management systems.ApplicationsEnergy measurement, monitoring and managementPower demand managementLoad shedding of connected devicesIntegration with SCADA, MES, IT, IoT and network management systems
PMC-5231M-4GC CR is a metal-cased power meter concentrator for energy monitoring and management projects. It gathers readings from ICP DAS PM Series Modbus power meters over RS-485 or Ethernet, and can also bring in M-7000 series and standard Modbus I/O modules, so that consumption data and device control sit in one unit. The 4G variant supports the China frequency band.Configuration is done entirely through a browser-based web interface, so no programming is needed. Power data can be viewed in real time or as history, and statistics reports are generated from the same pages. A built-in IF-THEN-ELSE logic engine and schedule functions support power demand management, with alarm messages sent via LINE, Telegram, Email or SMS.Power data is written to a microSD card and automatically sent back to the back-end system when a dropped network connection is restored. Integration with SCADA, MES and IoT platforms is provided through Modbus TCP/RTU, SNMP, FTP and MQTT, and connection to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar Cloud is supported.ApplicationsEnergy measurement, monitoring and managementPower demand managementPower consumption monitoring of devices with load shedding control
The PMC-5231M-4GE concentrates data from ICP DAS and standard Modbus power meters and I/O devices, then makes it available to energy monitoring and management systems. It suits engineers who need to measure consumption across a site and push the results to a SCADA, MES, IT or IoT back end over a cellular link.Configuration runs entirely in a web browser, so no separate software tool or custom programming is needed. Real-time and historical power data can be viewed and reported in the browser, and an IF-THEN-ELSE logic engine supports power demand management, with load shedding and alarm notification by LINE, Email or SMS.The 4G module is specified for the EMEA, Korea, Thailand, India and Taiwan frequency bands. A microSD card logs power data and sends the log files on automatically after a network outage. The metal case is designed for DIN-rail or wall mounting.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingRemote power data collection for SCADA, MES and IoT back-end systems
PMC-5236 CR is a power meter concentrator for energy monitoring and management projects. It collects readings from ICP DAS Modbus power meters and Modbus I/O modules over RS-485 or Ethernet, then presents the data through a browser-based configuration interface, so control logic and reports can be set up without writing code.Local intelligence covers power demand management and alarm handling. An IF-THEN-ELSE logic engine can switch I/O modules according to measured power status, supporting load shedding where required. Alarms can be sent via LINE, Telegram, Email or WeChat; the WeChat route needs an Enterprise WeChat account in China. Power data is logged to a microSD card and sent back automatically once a dropped network connection is restored.For integration, the unit supports Modbus TCP/RTU, SNMP, FTP and MQTT, and can connect to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar. The manufacturer lists this CR variant as For China Only, and the unit carries CE, UKCA, FCC, RoHS and WEEE marks.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower consumption reporting and statisticsIntegration with SCADA, MES and IoT platforms
The PMC-5236M CR is a DIN-rail power meter concentrator for energy monitoring and management. It gathers readings from ICP DAS Modbus power meters over RS-485 or Ethernet, and can also work with XV-Board and M-7000 I/O modules and standard Modbus TCP/RTU slave devices. Configuration, real-time and historical power data, and statistics reports are all handled through a web browser, so no separate software tool or programming is needed.For energy management, the unit supports an IF-THEN-ELSE logic engine, power demand management, Schedule and Timer operations, and load shedding of connected devices through its I/O modules. Power data is written to a microSD card, and log files are sent back automatically once a disconnected network is restored. Alarm messages can be sent via LINE, Telegram, Email or WeChat. The WeChat option needs an Enterprise WeChat account in China.This ordering code is the metal-case version listed as For China Only, so check the market restriction before ordering. Connectivity to back-end SCADA, MES, IT, IoT and network management systems is provided through Modbus TCP/RTU, SNMP, FTP and MQTT.ApplicationsEnergy measurement, monitoring and managementPower demand managementLoad shedding of connected devices
The PMC-5236M-4GC CR collects data from ICP DAS Modbus power meters over RS-485 or Ethernet and turns it into energy monitoring and management information. It is aimed at engineers building energy measurement systems who need power consumption tracked per device, with usage analysis and power demand management built in.Configuration is carried out entirely through a web browser, so no additional software tool or programming is needed. Logic is set up through web pages, and real-time or historical power data can be viewed and reported from the same interface. Power data is stored on a microSD card and sent back to the back-end system automatically once a lost network connection is restored.For control and alerts, the unit provides an IF-THEN-ELSE logic engine, timers, schedules and alarm messages via LINE, Telegram, Email, SMS or WeChat. Modbus I/O modules can be adjusted according to the power status. Integration with SCADA, IT and IoT platforms is supported through Modbus TCP/RTU, SNMP, FTP and MQTT, with connections to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar.ApplicationsEnergy measurement, monitoring and managementPower demand managementEnergy usage analysis and power consumption statistics
Industrial IoT Power Meter Concentrator (Support 4G communication. Frequency Band for EMEA, Korea, Thailand, India and Taiwan) (Metal Case).
The PMD-2201-EN is a panel-mounted power meter concentrator that gathers readings from ICP DAS Modbus power meters over RS-485 or Ethernet and stores them locally. Its built-in web server lets engineers view live and historical power data and set up the system from any browser, so no additional software tool or programming is needed.A 7-inch TFT display with a resistive touch panel provides on-site viewing and parameter setting. Connected Modbus I/O modules can be controlled from the power status, and an IF-THEN-ELSE logic engine supports power demand management, including load shedding where required. Alarms can be sent by LINE, Telegram or Email.For system integration, the unit supports Modbus TCP/RTU, SNMP, FTP and MQTT, and can connect to Microsoft Azure and IBM Bluemix IoT platforms. Power data is logged to a microSD card and sent back automatically once a disconnected network is restored. It can be powered from 12 ~ 48 VDC or from PoE (IEEE 802.3af).ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower data logging and statistical reporting
PMD-2201-SC is a browser-configured power meter concentrator for engineers building energy monitoring and management systems. It polls ICP DAS Modbus power meters over RS-485 or Ethernet, records the readings and makes them available locally on its 7" touch panel and remotely through its built-in web server, so most setup can be done without writing code.Control logic is handled on the device itself. A built-in IF-THEN-ELSE engine, timers and schedules can switch Modbus I/O modules according to power status, supporting power demand management and load shedding where required. Alarms can be sent via LINE, Telegram or Email, and power data can be logged to a microSD card and sent back automatically once a disconnected network is restored.For integration, the unit supports Modbus TCP/RTU, SNMP, FTP and MQTT, and can connect to Microsoft Azure and IBM Bluemix IoT platforms as well as the ICP DAS IoTstar cloud software. This Simplified Chinese version is designed for panel mounting and is powered from 12 ~ 48 VDC or PoE (IEEE 802.3af).ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower data logging and historical power reportingRemote alarm notification for power systems
The PMD-2201-TC CR is a panel-mount power meter concentrator for engineers who need to collect, log and act on energy data without writing control software. Configuration is done in a browser or on the local 7" touch display, so logic, schedules and reports are set up through web pages rather than programmed. The -TC suffix identifies the Traditional Chinese variant.The unit reads ICP DAS Modbus power meter modules and Modbus I/O modules over two RS-485 ports and one RJ-45 Ethernet port. Up to 24 power meter modules plus 8 I/O modules can be connected, subject to a maximum of 16 Modbus TCP modules in total. A built-in IF-THEN-ELSE logic engine supports power demand management, and I/O modules can be switched according to power status, for example to shed loads.Measured values are logged to a microSD card, with data log files sent back automatically once a disconnected network is restored. Alarm messages can be sent via LINE, Telegram or Email, and the unit supports Modbus TCP/RTU, SNMP, FTP and MQTT for integration with SCADA, MES and IoT platforms, including Microsoft Azure and IBM Bluemix.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower usage efficiency (PUE) monitoring
The PMD-2206-EN is a web-based power meter concentrator for energy measurement, monitoring and management. It reads power data from ICP DAS Smart Power Meters over RS-485 or Ethernet, logs the values to a microSD card and presents them on a 7-inch TFT touch panel, in a browser or both. Configuration is done through built-in web pages, so no separate software tool or programming is needed.The unit combines power demand management with I/O control. An IF-THEN-ELSE logic engine can act on power status through Modbus I/O modules, including load shedding where required, and a schedule function governs I/O device operation. Alarm messages can be sent via LINE, Telegram, Email or WeChat, and data can be forwarded to Modbus TCP/RTU, SNMP, FTP and MQTT systems or to Microsoft Azure and IBM Bluemix IoT platforms.This ordering code is listed as For China Only in the product description. The WeChat notification feature requires an Enterprise WeChat account in China.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower data logging and statistical reportingSCADA, MES and IoT integration of power data
PMD-2206-SC CR is a web-based power meter concentrator that collects power data from ICP DAS Modbus power meters and I/O modules, records it to a microSD card and presents it on a built-in 7-inch touch panel or through a browser. Configuration is done through web pages, so no separate software tool or programming is needed to set up logic control.The unit reads power meters over its two RS-485 COM ports or over Ethernet, supporting up to 24 ICP DAS Modbus power meter modules and 8 Modbus I/O modules in total. An IF-THEN-ELSE logic engine, timers and schedules let it adjust I/O devices according to power status, which supports power demand management and load shedding. Alarms can be sent by LINE, Telegram, Email or WeChat.Data is shared with back-end systems over Modbus TCP/RTU, SNMP, FTP and MQTT, and it can connect to Microsoft Azure, IBM Bluemix or ICP DAS IoTstar Cloud. This is the Simplified Chinese version, intended for China only, and its WeChat alarm function requires an Enterprise WeChat account in China.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingAlarm notification for power consumption
The PMD-2206-TC CR is a web-based power meter concentrator that collects power data from ICP DAS Modbus power meters over RS-485 or Ethernet, logs it locally and presents it through a browser or its onsite display. Configuration is done in the web interface, so no separate software tool or programming is needed to set up a monitoring system.Control and alarm logic is handled by a built-in IF-THEN-ELSE engine, which supports power demand management and can shed load on connected devices where required. Alarms can be sent via LINE, Telegram, Email or WeChat, with WeChat delivery requiring an Enterprise WeChat account in China. Data logs are stored on microSD and sent back automatically once a disconnected network is restored.The unit has a 7-inch TFT LCD with a resistive touch panel and is designed for panel mounting, with PoE (IEEE 802.3af) or a 12 ~ 48 VDC supply. It supports Modbus TCP/RTU, SNMP, FTP and MQTT for integration with SCADA, MES and IoT back-end systems. This ordering code is the Traditional Chinese interface version, supplied for China only.ApplicationsEnergy measurement, monitoring and managementPower demand management and load sheddingPower usage effectiveness (PUE) monitoring
PMD-4201-EN CR is a browser-configured power meter concentrator for energy measurement, monitoring and management. It polls ICP DAS power meters over RS-485 or Ethernet, records readings to a microSD card, and gives local and remote access to the data without a separate configuration tool.Power demand management is handled on the device itself. A built-in IF-THEN-ELSE logic engine works with Modbus I/O modules to adjust equipment according to power status, and alarms can be sent by LINE, Telegram or Email. Connected devices can be shed when required, which suits sites that need to limit consumption in real time.Integration with supervisory and IT systems uses Modbus TCP/RTU, SNMP, FTP and MQTT, along with connection to Microsoft Azure, IBM Bluemix and ICP DAS IoTstar Cloud. The 10.4" touch panel supports local viewing and parameter setting, and PoE is supported for power.ApplicationsEnergy measurement, monitoring and managementPower demand management with load shedding of connected devices