I-7011PD 1-ch Thermocouple Input Module with LED Display, DCON
RS-485 DCON I/O module with a 16-bit analogue input for thermocouple, voltage or current signals, a 5-digit LED display, a digital input counter and two alarm outputs.
- 1 differential analogue input for thermocouple (J, K, T, E, R, S, B, N, C, L, M), voltage or current
- 16-bit resolution with ±0.1% of FSR accuracy and open wire detection for thermocouple inputs
- 1 digital input (dry contact) functioning as a 50 Hz event counter
- 2 open-collector sink digital outputs for high/low alarm, 30 mA per channel
- 5-digit 7-segment LED display plus power and communication LED
- RS-485 port with DCON protocol at 1200 ~ 115200 bps
240,00 € per piece
| 1–9 pcs | 240,00 € | |
|---|---|---|
| 10–30 pcs | 233,00 € | −3 % |
| 31+ pcs | 228,00 € | −5 % |
Informácie o výrobku "I-7011PD 1-ch Thermocouple Input Module with LED Display, DCON"
I-7011PD CR is a remote I/O module from the I-7000 series that brings one differential analogue input, one digital input and two digital outputs onto an RS-485 DCON network. The analogue input accepts thermocouple, voltage or current signals, so a single module can cover a range of sensor types in building, factory and machine automation.
The "P" variant adds support for thermocouple types L and M alongside J, K, T, E, R, S, B, N and C. Open thermocouple detection is provided on the analogue input. The digital input works as a 50 Hz event counter, and the two open-collector outputs can be used as high/low alarms with programmable power-on and safe values. Current input requires an optional external 125 Ω resistor.
A 5-digit 7-segment LED display and a power and communication LED give local status at a glance. The module has 3000 VDC intra-module isolation, a built-in dual watchdog and a DIN-rail housing measuring 72 x 123 x 35 mm. It operates from +10 ~ +30 VDC over a temperature range of -25 ~ +75 °C.
Applications
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
| Product type: | Analog Input Module |
|---|---|
| Interface: | RS-485 |
| Protocol: | DCON |
| Digital inputs: | 1 |
| Digital outputs: | 2 |
| Analog inputs: | 1 |
| Ports: | 1 |
| Isolation: | 3000 VDC |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Module, Communication (Programmable) |
| Display | |
| Type | 5-Digit 7 Segment LED Display |
| Isolation | |
| Intra-module Isolation | 3000 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| ESD (IEC 61000-4-2) | ±2 kV Contact for Each Terminal |
| Surge (IEC 61000-4-5) | ±0.5 kV for Power Line |
| LED Indicators | |
| Status | 1 x Power and Communication |
| Analog Input | |
| Channels | 1 Differential |
| Type | Voltage Current Thermocouple |
| Sensor Type | Thermocouple: J, K, T, E, R, S, B, N, C, L, M |
| Range | Voltage: ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V Current: ±20 mA (requires an optional external 125 Ω resistor) |
| Resolution | 16-bit |
| Accuracy | ±0.1% of FSR |
| Sampling Rate | 10 Hz (Total) |
| Input Impedance | > 400 kΩ |
| Common Voltage Protection | ±5 VDC |
| Overvoltage Protection | ±5 VDC |
| Open Wire Detection | For Thermocouple Only |
| Digital Input/Counter | |
| Channels | 1 |
| Type | Dry Contact |
| Sink/Source (NPN/PNP) | Source |
| ON Voltage Level | Close to GND |
| OFF Voltage Level | Open |
| Input Impedance | 3 kΩ |
| Overvoltage Protection | ±30 VDC |
| Digital Output | |
| Channels | 2 |
| Type | Open Collector |
| Sink/Source (NPN/PNP) | Sink |
| Load Voltage | +3.5 ~ +30 VDC |
| Load Current | 30 mA/channel |
| Power on Value | Programmable |
| Safe Value | Programmable |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Data Format | (N, 8, 1) |
| Protocol | DCON |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +30 VDC |
| Consumption | 1.5 W |
| Mechanical | |
| Dimensions (mm) | 72 x 123 x 35 (W x L x H) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +85 °C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.