MDR-60-48 DIN-Rail Power Supply, 85~264 VAC to 48 VDC/1.25 A, 60 W
MDR-60-48 CR is a 60 W DIN-rail power supply that accepts a universal 85~264 VAC input and delivers 48 VDC at 1.25 A, with short-circuit, overload and over-voltage protection.
- Universal AC input, 85 ~ 264 VAC, 47 ~ 63 Hz
- 48 VDC output, 1.25 A rated, 60 W rated power
- Output voltage adjustable from 48 ~ 56 V
- Short-circuit, overload and over-voltage protection
- DC OK relay contact and LED indicator for power on
- NEC class 2/LPS compliant at 48 V output
56,00 € per piece
| 1–9 pcs | 56,00 € | |
|---|---|---|
| 10–30 pcs | 55,00 € | −2 % |
| 31+ pcs | 53,00 € | −5 % |
Informacije o izdelku "MDR-60-48 DIN-Rail Power Supply, 85~264 VAC to 48 VDC/1.25 A, 60 W"
The MDR-60-48 CR converts a universal 85~264 VAC mains input into a regulated 48 VDC output rated at 1.25 A, or 60 W. It suits engineers who need a compact, DIN-rail mounted supply for control cabinet equipment that runs from a 48 V DC bus.
The output voltage can be trimmed between 48 and 56 V. Protective functions include shutdown on over-voltage, which recovers after re-powering, and constant current limiting on overload that recovers automatically once the fault is cleared. A DC OK relay contact and a power-on LED aid monitoring and commissioning.
Standards cited for this model include UL508, TUV EN60950-1 and NEC class 2/LPS compliance on the 48 V output, plus EMC compliance to EN55011, EN55022 and EN61000-6-2. Operating range is -20 ~ +70 °C, with 20 ~ 90% RH non-condensing humidity.
Applications
- Supplying 48 VDC to DIN-rail mounted equipment in industrial control cabinets
| Product type: | Power supply |
|---|---|
| Power input: | 85 ~ 264 VAC |
| Operating temperature: | -20 ~ +70 °C |
| Mounting: | DIN-rail |
| Housing: | Plastic |
Specifications
| Safety | |
|---|---|
| Standard | UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (24V,48V only) |
| EMC | |
| Standard | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
| Input | |
| Voltage Range | 85 ~ 264 VAC 120 ~ 370 VDC |
| Frequency Range | 47 ~ 63 Hz |
| Inrush Current (Typ.) | COLD START 30 A/115 VAC 60 A/230 VAC |
| Leakage Current | <1 mA / 240 VAC |
| Output | |
| Ripple & Noise (Max.) | 200mVp-p |
| Voltage Adj. Range | 48 ~ 56 V |
| Voltage Tolerance | ±1.0% |
| Linearity | ±1.0% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 500 ms, 30 ms/230 VAC 500 ms, 30 m/115 VAC at full load |
| Hold Up Time (Typ.) | 50 ms/230 VAC 20 ms/115 VAC at full load |
| DC Voltage | 48 V |
| Rated Power | 60 W |
| Rated Current | 1.25 A |
| Efficiency | 87% |
| Protection | |
| Over Voltage | 57.6 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover |
| Overload | 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed |
| Function | |
| DC OK Active Signal (Max.) | 30V/1A resistive |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | (40 * 90 * 100) mm |
| Environment | |
| Operating Temperature | -20 ~ +70 °C |
| Storage Temperature | -40 ~ +85°C |
| Humidity | 20 ~ 90% RH Non-condensing |
Specifications as published by the manufacturer. Subject to change.