Preskoči na glavno vsebino Preskoči na iskanje Preskoči na glavno navigacijo

ECAT-2610 EtherCAT to Modbus RTU Gateway, RS-232/422/485

Informacije o izdelku "ECAT-2610 EtherCAT to Modbus RTU Gateway, RS-232/422/485"

The ECAT-2610 CR brings serial RS-232/422/485 equipment into an EtherCAT control system without modifying the connected device. It presents as an EtherCAT SubDevice on the network side and as a Modbus RTU Main Device on the serial side, so the controller receives the serial data as ordinary I/O.

Protocol conversion takes place inside the gateway, so no PLC function blocks are required. It exchanges up to 256 WORD of input and 256 WORD of output data, and the serial port supports baud rates up to 115200 bps. Two RJ-45 EtherCAT connectors are provided, with a maximum distance of 100 m between stations over 100BASE-TX.

The ordering code includes a CA-0915 DB9 male to DB9 female cable, 1.5 m. The unit has a plastic housing for DIN-rail mounting, accepts +12 VDC to +48 VDC input and is rated for operation from -25 to +75 °C.

Applications

  • Retrofitting older automation devices into modern EtherCAT communication structures
  • Integrating serial RS-232/422/485 devices into EtherCAT control systems
Product type: Gateway
Interface: RS-232/422/485
Protocol: EtherCAT, Modbus RTU
Ports: 1 x RS-232/422/485, 2 x RJ-45
Power input: +12 ~ +48 VDC
Operating temperature: -25 ~ +75 °C
Mounting: DIN-rail
Housing: Plastic

Specifications

COM Ports
Ports1 x RS-232/422/485
ProtocolModbus RTU (Master)
EtherCAT
PortsRJ-45 x 2
Distance between Stations: Max. 100 m (100BASE-TX)
Data Transfer Medium: Ethernet/EtherCAT Cable (Min. CAT 5e)
Cycle Time10 ms
Distributed ClocksN/A
Power
Reverse Polarity ProtectionYes
Input Range+12 VDC ~ +48 VDC
Consumption0.1 A @ 24 VDC
Mechanical
CasingPlastic
Dimensions (mm)33 x 127 x 99 (W x L x H)
InstallationDIN-Rail
Environment
Operating Temperature-25 ~ +75 °C
Storage Temperature-30 ~ +80 °C
Humidity10 ~ 90% RH, Non-condensing

Specifications as published by the manufacturer. Subject to change.

0 od 0 ocen

Povprečna ocena 0 od 5 zvezdic

Pustite pregled!

Delite svoje izkušnje z drugimi strankami.


Preskoči galerijo izdelkov

Podobni izdelki

ECAT-2610-DW EtherCAT SubDevice to Modbus RTU and Power Meter Gateway
ECAT-2610-DW CR ECAT-2610-DW EtherCAT SubDevice to Modbus RTU and Power Meter Gateway

ECAT-2610-DW is a gateway that converts EtherCAT to Modbus RTU, so a serial device on its RS-232/422/485 port can be integrated into an EtherCAT network. It also integrates PM-3033/3133/3114/3112 power meter SubDevices, with the Main Device reaching their RxPDO and TxPDO data through a configuration file supplied by ICP DAS.The unit suits system integrators who want to retro-fit older automation equipment into modern EtherCAT structures. Several power meters can be connected at once, supporting more diversified energy management programs. The source notes a simple installation and configuration process.The gateway is supplied as the CR ordering code with a CA-0915 DB9 Male to DB9 Female cable, 1.5 M. It is certified to CE, UKCA, FCC, RoHS and WEEE and mounts on a DIN-rail in a plastic housing.ApplicationsRetro-fitting older automation devices into EtherCAT control systemsEnergy management and power monitoring with multiple power metersIntegrating Modbus RTU serial devices into EtherCAT networks

Redna cena: 403,00 € per piece · volume discount from 10 pcs
ECAT-2611 EtherCAT to Modbus RTU Protocol Gateway, RS-232/422/485
ECAT-2611 CR ECAT-2611 EtherCAT to Modbus RTU Protocol Gateway, RS-232/422/485

The ECAT-2611 CR is a protocol converter gateway that connects EtherCAT and Modbus RTU networks. It operates as a SubDevice on both sides and passes I/O data between them, so an EtherCAT Main Device and a Modbus RTU Main Device can exchange data through its internal data exchange buffer.It suits system integrators who need to bring older serial automation equipment into an EtherCAT architecture. The serial protocol conversion is handled in the module, so no PLC function blocks are required and the connected device needs no hardware or software changes.This CR ordering code includes the CA-0915 DB9 male to DB9 female cable, 1.5 M, for connecting the serial port. Key figures include a 10 ms cycle time, up to 256 WORD input and 256 WORD output data, and serial communication up to 115200 bps.ApplicationsRetrofitting older Modbus RTU automation devices into EtherCAT communication structuresExchanging I/O data between an EtherCAT Main Device and a Modbus RTU Main DeviceIntegrating serial Modbus RTU equipment into EtherCAT-based machine control systems

Redna cena: 386,00 € per piece · volume discount from 10 pcs
ECAT-2601 EtherCAT MainDevice Gateway for Modbus and OPC UA
ECAT-2601 CR ECAT-2601 EtherCAT MainDevice Gateway for Modbus and OPC UA

The ECAT-2601 CR is a gateway that connects an EtherCAT network with Modbus and OPC UA systems. Its built-in EtherCAT MainDevice drives EtherCAT SubDevices directly, and a shared data exchange buffer makes their I/O data available to Modbus masters over Modbus TCP and Modbus RTU (slave).Engineers will value that it connects to SubDevice PDO without requiring an ESI file and supports third-party EtherCAT SubDevices. Free Run mode is supported, the minimum cycle time is 125us, and it reconnects to SubDevices within 10 seconds after power-on. User-defined SDO startup entries can be set, and configuration is handled through the built-in web interface over HTTP/HTTPS.An OPC UA Server in the firmware lets standard OPC UA clients connect without custom development, covering machine-to-machine communication as well as links to SCADA systems and cloud platforms. The ordering code ECAT-2601 CR denotes the RoHS-compliant version, and the unit mounts on DIN-rail.ApplicationsMachine-to-machine data exchange between EtherCAT and Modbus systemsVertical integration of EtherCAT machines with SCADA systemsConnecting EtherCAT machines to cloud platforms via OPC UAIntegrating third-party EtherCAT SubDevices into Modbus or OPC UA networks

Redna cena: 1.054,00 € per piece · volume discount from 10 pcs
GW-7552-B PROFIBUS DP-V0 to Modbus RTU/ASCII Gateway, Plastic Case
GW-7552-B CR GW-7552-B PROFIBUS DP-V0 to Modbus RTU/ASCII Gateway, Plastic Case

The GW-7552-B connects Modbus devices to a PROFIBUS DP network. It acts as a DP-V0 slave towards the PROFIBUS master, so the master can read and write data held by Modbus devices such as PLCs, sensors and ICP DAS M-7000 series modules, without changes to the PROFIBUS network design.The gateway can operate as a Modbus master or slave and supports both RTU and ASCII formats. Its hybrid COM 1 port is selectable between RS-232, RS-422 and RS-485, with the modes used one at a time. Serial settings cover 7 or 8 data bits, no, odd or even parity, 1 or 2 stop bits, and baud rates from 1200 to 115200. A utility is provided for configuring the GW-7552-B.Transmission rate on the PROFIBUS side is detected automatically, and the node address is set from 0 to 126 using a DIP switch. The PROFIBUS side has 3000 VDC isolation, and the network side uses High Speed iCoupler isolation. The GW-7552-B is housed in a plastic case for DIN-rail mounting, with an operating range of -25 ~ +75 °C.ApplicationsIndustrial automationFactory automationProcess automation

Redna cena: 450,00 € per piece · volume discount from 10 pcs