tM-AD8C Isolated 8-Channel Current Input Module, 0 ~ 20 mA / 4 ~ 20 mA
RS-485 remote analog input module with eight single-ended current inputs, programmable 0 ~ 20 mA or 4 ~ 20 mA ranges and 2500 VDC intra-module isolation.
- Eight single-ended current inputs with a programmable 0 ~ 20 mA or 4 ~ 20 mA range on all channels
- Selectable normal mode (14-bit, ±0.1%, 10 Hz) or fast mode (12-bit, ±0.5%, 200 Hz) sampling
- 1 x RS-485 port supporting DCON, Modbus RTU and Modbus ASCII
- Baud rates from 1200 to 115200 bps with (N, 8, 1), (N, 8, 2), (O, 8, 1) and (E, 8, 1) data formats
- Dual watchdog for module and communication
- 2500 VDC intra-module isolation and 4 kV ESD protection
138,00 € per piece
| 1–9 pcs | 138,00 € | |
|---|---|---|
| 10–30 pcs | 134,00 € | −3 % |
| 31+ pcs | 131,00 € | −5 % |
Informácie o výrobku "tM-AD8C Isolated 8-Channel Current Input Module, 0 ~ 20 mA / 4 ~ 20 mA"
The tM-AD8C CR is an RS-485 current input module for engineers who need eight single-ended analog inputs on a DIN-rail node. Every channel can be set to either the 0 ~ 20 mA or the 4 ~ 20 mA range, so one module suits common process-signal transmitters without any change to the wiring scheme.
Sampling can be switched between a normal mode, which gives 14-bit resolution at ±0.1% accuracy and 10 Hz, and a fast mode, which gives 12-bit resolution at ±0.5% accuracy and 200 Hz. The module supports DCON, Modbus RTU and Modbus ASCII over its RS-485 port, with baud rates from 1200 to 115200 bps, and it provides a dual watchdog covering the module and the communication link.
Electrical robustness is built in, with 2500 VDC intra-module isolation, ±4 kV EFT protection on power and ±4 kV contact / ±8 kV air ESD protection. The unit is powered from 10 ~ 30 VDC with reverse polarity protection and operates from -25 ~ +75 °C.
Applications
- Industrial Automation
- Industrial Machinery
- Building Automation
- Food and Beverage Systems
- Semiconductor Fabrication
- Control Systems
| Product type: | Analog Input Module |
|---|---|
| Interface: | RS-485 |
| Protocol: | DCON, Modbus ASCII, Modbus RTU |
| Analog inputs: | 8 |
| Ports: | 1 |
| Isolation: | 2500 VDC |
| Power input: | 10 ~ 30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Module, Communication (Programmable) |
| Isolation | |
| Intra-module Isolation | 2500 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power |
| ESD (IEC 61000-4-2) | ±4 kV Contact for Each Terminal ±8 kV Air for Random Point |
| LED Indicators | |
| Status | 1 x Power and Communication |
| Analog Input | |
| Channels | 8 Single-ended |
| Type | Current |
| Range | 0 ~ 20 mA, 4 ~ 20 mA |
| Resolution | Normal Mode: 14-bit Fast Mode: 12-bit |
| Accuracy | Normal Mode: ±0.1% Fast Mode: ±0.5% |
| Sampling Rate | Normal Mode: 10 Hz Fast Mode: 200 Hz |
| Input Impedance | 125 Ω |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Data Format | (N, 8, 1), (N, 8, 2), (O, 8, 1), (E, 8, 1) |
| Protocol | DCON, Modbus RTU, Modbus ASCII |
| Power | |
| Reverse Polarity Protection | Yes |
| Consumption | 0.7 W max. |
| Powered from Terminal Block | 10 ~ 30 VDC |
| Mechanical | |
| Dimensions (mm) | 52 x 98 x 27 (W x L x H) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +75 °C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.
Downloads