ET-7200
Ethernet I/O Module with 10-ch Thermocouple Input, 6-ch DO. Includes DB-1820 Daughter Board.
Ethernet I/O Module with 10-ch Thermocouple Input, 6-ch DO. Includes DN-1822 Daughter Board, CA-252518D-1 1.8 m Cable, 4PAPP-006-G.
Ethernet I/O Module with 10-ch Thermocouple Input, 6-ch DO. Includes DN-1823 Daughter Board, CA-2525015D 15 cm Cable, 4PAPP-006-G.
Ethernet I/O Module with Universal 10-ch AI, 6-ch DO. Includes DB-1820 Daughter Board.
Ethernet I/O Module with Universal 10-ch AI, 6-ch DO. Includes DN-1822 Daughter Board, CA-252518D-1 1.8 m Cable, 4PAPP-006-G.
Ethernet I/O Module with Universal 10-ch AI, 6-ch DO. Includes DN-1823 Daughter Board, CA-2525015D 15 cm Cable, 4PAPP-006-G.
The ET-7202 CR brings analogue sensing, digital counting and relay switching into one DIN-rail Ethernet I/O module. Each of its three differential analogue inputs can be set to voltage or current ranges from ±150 mV up to ±10 V and 0 ~ 20 mA, ±20 mA or 4 ~ 20 mA, with the mode selected by jumper. Each input is protected against 240 Vrms overvoltage, which suits mixed signal environments.The six digital inputs are wet-contact, sink/source compatible, with 32-bit counters and a 100 Hz frequency rating, so they can handle both status monitoring and simple pulse counting. The three Form A power relays are rated 5 A at 250 VAC or 24 VDC for resistive loads, and their power-on and safe values are programmable.Built-in 2-port 10/100 Base-TX switching with LAN bypass allows the module to be daisy-chained along a network, while the Modbus TCP and Modbus UDP protocols and the built-in web server with web HMI simplify integration and configuration. Isolation is rated at 2500 VDC for I/O and 1500 VDC for Ethernet.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7204 CR is a multifunction Ethernet I/O module that combines four analogue inputs, four analogue outputs and four digital inputs or counters in one DIN-rail unit. Each analogue input can be set to a suitable range, with 240 Vrms overvoltage protection, and each analogue input or output can be switched between voltage and current using its jumper position.An integrated 2-port 10/100 Base-TX switch with LAN bypass allows the module to be daisy-chained along a network line without a separate switch. Modbus TCP and Modbus UDP are supported, and the built-in web server provides a Web HMI for configuration and monitoring.Engineers typically choose the ET-7204 CR for building and factory automation, machine control, and remote maintenance or diagnosis projects, as well as test equipment. Dual watchdogs and programmable power-on and safe output values help keep the process in a defined state.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7215 is an Ethernet I/O module for temperature measurement with resistance temperature detectors over long cable runs. Each of its seven differential channels can be configured individually for Pt100, Pt1000, Ni120, Cu100 or Cu1000 sensors, and three-wire RTD lead resistance is compensated automatically, whatever the wire length.The built-in 2-port 10/100 Base-TX switch with LAN bypass allows modules to be daisy-chained along a network line. Communication runs over Modbus TCP or Modbus UDP, and the built-in web server and Web HMI let you check and configure the unit from a browser, with ID, password and IP filter access control.Suited to building automation, factory and machine automation, and remote diagnosis or maintenance, the ET-7215 is ordered as ET-7215 CR. It carries CE, UKCA, FCC, RoHS and WEEE marks and operates from +12 ~ +48 VDC over a temperature range of -25 ~ +75 °C.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7217 CR is an Ethernet remote I/O module for engineers who need to acquire sensor signals and switch outputs over a Modbus network. It provides eight differential analogue inputs, each of which can be configured with its own range. Input type is set by jumper, so each channel can accept voltage or current, and the inputs are protected against overvoltage up to 240 Vrms.On the network side, the module includes a 2-port 10/100 Base-TX switch with LAN bypass, which allows devices to be daisy-chained along a line. It supports Modbus TCP and Modbus UDP, and includes a built-in web server with web HMI, access control by ID, password and IP filter, and communication security features. The sampling rate can be switched between normal and fast modes.The four digital outputs are isolated open-collector sink types with short-circuit and overload protection, and can be given programmable power-on and safe values. The module offers 2500 VDC I/O isolation and 4 kV ESD protection, and is designed for DIN-rail mounting over an operating range of -25 ~ +75 °C.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7217-10 CR brings analogue signal acquisition onto Ethernet, with 10 differential or 20 single-ended analogue inputs that can be configured channel by channel. Each channel is set to a voltage or current range in software, and the matching hardware jumper selects voltage or current input, so one module can handle a mixed set of sensor signals.Engineers will value the built-in 2-port switch with LAN bypass, which lets modules be daisy-chained along a line without a separate switch. The module offers a built-in web server with web HMI, Modbus TCP and Modbus UDP communication, and Communication Security with ID, password and IP filter access control. Two sampling modes let you trade speed against accuracy, with the normal mode rated at 10 Hz and the fast mode at 50 Hz across all channels.Protection features include 240 Vrms overvoltage protection on differential inputs, ±4 kV contact ESD protection on each terminal, and isolation rated at 2500 VDC on I/O and 1500 VDC on Ethernet. The module runs from +12 ~ +48 VDC and operates between -25 ~ +75 °C, and it mounts on a DIN rail.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7217-A5 combines eight differential high-voltage analog inputs and four digital outputs in a DIN-rail Ethernet module. Each input channel can be set independently to ±50 V or ±150 V, so one module can cover mixed voltage signals without extra signal conditioning. Digital outputs are isolated open-collector sink type, rated for 700 mA per channel.Networking is handled by a built-in 2-port 10/100 Base-TX switch with LAN bypass, which allows modules to be daisy-chained along a line. The module supports Modbus TCP and Modbus UDP, and a built-in web server with web HMI allows configuration and remote monitoring from a browser. Access control uses ID, password and IP filter.Reliability features include a dual watchdog covering the module and communication, programmable power-on and safe values for the digital outputs, and I/O pair connection. Isolation is rated at 2500 VDC for I/O and 1500 VDC for Ethernet. The module operates from -25 ~ +75 °C.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7217RMS converts AC input signals into their True RMS DC equivalents, so engineers can read the RMS value of complex waveforms over Ethernet. Each of its 8 differential analogue channels can be configured individually, with an input range from +150 mVrms to +10 Vrms.Four isolated open-collector digital outputs are built in, with programmable power-on and safe values. The 2-port 10/100 Base-TX switch with LAN bypass supports daisy-chain topologies, and the module communicates via Modbus TCP and Modbus UDP.The module includes a built-in web server with web HMI, access control by ID, password and IP filter, and dual watchdog protection. It is DIN-rail mounted and specified for an operating temperature of -25 ~ +75 °C.ApplicationsMonitoring AC signal levels as True RMS DC valuesDaisy-chained Ethernet I/O networks with Modbus TCP or Modbus UDP host systemsRemote acquisition and switching in DIN-rail control cabinets
Ethernet I/O Module with 2-port Ethernet Switch, 10-ch Thermocouple Input, 3-ch DO. Includes DB-1820 Daughter Board.
Ethernet I/O Module with 2-port Ethernet Switch, 10-ch Thermocouple Input, 3-ch DO. Includes DN-1822 Daughter Board, CA-252518D-1 1.8 m Cable, 4PAPP-006-G.
Ethernet I/O Module with 2-port Ethernet Switch, 10-ch Thermocouple Input, 3-ch DO. Includes DN-1823 Daughter Board, CA-2525015D 15 cm Cable, 4PAPP-006-G.
Ethernet I/O Module with 2-port Ethernet Switch, Universal 10-ch AI, 3-ch DO. Includes DB-1820 Daughter Board.
Ethernet I/O Module with 2-port Ethernet Switch, Universal 10-ch AI, 3-ch DO. Includes DN-1822 Daughter Board, CA-252518D-1 1.8 m Cable, 4PAPP-006-G.
Ethernet I/O Module with 2-port Ethernet Switch, Universal 10-ch AI, 3-ch DO. Includes DN-1823 Daughter Board, CA-2525015D 15 cm Cable, 4PAPP-006-G.
The ET-7224 CR combines analogue output, digital input and digital output channels in one DIN-rail Ethernet I/O module. Each of its four analogue outputs can be set by jumper to voltage or current, covering +/-5 V, +/-10 V, 0 ~ 20 mA and 4 ~ 20 mA, which suits engineers who need to drive a mix of field actuators from a single module.Communication is handled over Modbus TCP and Modbus UDP, with a built-in web server and web HMI for configuration and monitoring. The integrated 2-port 10/100 Base-TX switch, with LAN bypass, allows the module to be daisy-chained along a network line without a separate switch at each node.Designed for building, factory and machine automation as well as remote maintenance and diagnosis, the module offers dual watchdogs, programmable power-on and safe values for outputs, and 2500 VDC I/O isolation with 1500 VDC Ethernet isolation.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7226 CR is an Ethernet I/O module that brings mixed analogue and digital signals onto a Modbus network from a single DIN-rail unit. It suits engineers who need six differential analogue inputs and two analogue outputs alongside two digital inputs (with counter function) and two digital outputs, without adding separate remote I/O modules.Each analogue input can be configured individually for voltage or current ranges, including +/-500 mV, +/-1 V, +/-5 V, +/-10 V, 0 ~ 20 mA, +/-20 mA and 4 ~ 20 mA, with the input type set by jumper. Open wire detection is available for 4 ~ 20 mA inputs. The analogue outputs support voltage and current ranges, and the power-on and safe values of the outputs are programmable.The built-in two-port 10/100 Base-TX switch with LAN bypass supports daisy-chain wiring, and the module offers Modbus TCP and Modbus UDP, a built-in web server and Web HMI, and access control by ID, password and IP filter. Isolation is rated at 1500 VDC on the Ethernet side and 2500 VDC on the I/O side.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7228 provides eight analogue output channels for engineers who need Ethernet-based control of analogue field devices. Each channel can be set to voltage (+0 ~ +5 VDC, ±5 VDC, +0 ~ +10 VDC, ±10 VDC) or current (0 ~ 20 mA, 4 ~ 20 mA) using the jumper for that channel, so one module can cover mixed field devices.Modbus TCP and Modbus UDP are supported, and the built-in web server and Web HMI provide browser-based access to the module. The two RJ-45 switch ports with LAN bypass allow daisy-chain topologies, and the power-on and safe values of each output are programmable.Isolation is rated at 1500 VDC for Ethernet and 2500 VDC for I/O. The module runs from +12 ~ +48 VDC with reverse polarity protection, and is designed for DIN-rail mounting over an operating range of -25 ~ +75 °C.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
ET-7242 CR is an Ethernet I/O module that drives 16 sink-type digital outputs and reports their status over Modbus TCP or Modbus UDP. Its built-in web server and web HMI allow configuration and monitoring from a standard browser, which suits engineers who want to commission and check I/O without dedicated software.The built-in 2-port 10/100 Base-TX switch with LAN bypass lets the module sit in a daisy-chain topology, so cabling between I/O points can be simplified. Each output has a load voltage range of +3.5 ~ +50 VDC and up to 650 mA per channel at 25°C, and the outputs can directly drive an RM series relay module to switch inductive loads. Power-on and safe values are programmable, so outputs can be set to a defined state at start-up or on communication loss.I/O is optically isolated to 3750 VDC for transient overvoltage protection, while Ethernet is isolated to 1500 VDC. Channels are not isolated from each other. The module is DIN-rail mounted and specified for an operating range of -25 ~ +75 °C.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7242-UT is an Ethernet-connected I/O module providing 16 isolated open-collector sink-type digital outputs. Each channel carries up to 650 mA at 25°C and can directly drive a power relay module, which is useful when switching inductive loads.The built-in web server and Web HMI let engineers configure and monitor the module from a browser, while Modbus TCP and Modbus UDP provide host communication. The integrated 2-port 10/100 Base-TX switch with LAN bypass supports daisy-chain wiring. Dual watchdogs for the module and communication are programmable, and the power-on and safe values of each digital output can be set.Optical isolation is rated at 3750 VDC on the I/O side and 1500 VDC on the Ethernet side. ESD, EFT and surge protection are specified to IEC 61000-4-2, -4-4 and -4-5. The module is rated for -40 to 75 °C operation and mounts on DIN-rail.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment