M-2018-16 16-ch Thermocouple Input Module, RS-485 Modbus RTU and DCON
16-channel differential analog input module for thermocouple, voltage and current signals, with RS-485 communication over Modbus RTU or DCON and 3000 VDC I/O isolation.
- 16 differential analog input channels
- Thermocouple (J, K, T, E, R, S, B, N, C), voltage and current input types
- Open-wire detection on thermocouple channels and adjustable CJC offset
- 16-bit resolution, 0.1% of FSR accuracy, 10 Hz total sampling rate
- 120 VDC overvoltage protection and EMS protection (EFT, ESD, surge)
- 1 x RS-485 port with Modbus RTU and DCON, 1200 ~ 115200 bps
281,00 € per piece
| 1–9 pcs | 281,00 € | |
|---|---|---|
| 10–30 pcs | 273,00 € | −3 % |
| 31+ pcs | 267,00 € | −5 % |
Informácie o výrobku "M-2018-16 16-ch Thermocouple Input Module, RS-485 Modbus RTU and DCON"
The M-2018-16 CR is a 16-channel differential analog input module for RS-485 networks. Each channel accepts thermocouple, voltage or current signals, so one module can cover several sensor types in a single DIN-rail point. Thermocouple channels include open-wire detection, which helps engineers spot a broken sensor loop quickly.
Front-end protection is built in. The inputs tolerate a 120 VDC overvoltage and include EMS protection against EFT, ESD and surge events, while 3000 VDC intra-module isolation supports reliable operation in electrically noisy plants. A 16-bit resolution and 0.1% of FSR accuracy give stable readings for process monitoring.
Communication uses an RS-485 port that supports Modbus RTU and DCON, with baud rates from 1200 to 115200 bps. A programmable module and communication watchdog helps the module recover from faults, and the unit runs from a +10 to +48 VDC supply across a -25 to +75 °C operating range.
Applications
- Temperature measurement with thermocouple sensors in industrial automation
- Voltage and current signal acquisition on RS-485 Modbus RTU or DCON networks
- Process monitoring in electrically demanding industrial environments
| Product type: | Analog Input Module |
|---|---|
| Interface: | RS-485 |
| Protocol: | DCON, Modbus RTU |
| Analog inputs: | 16 |
| Ports: | 1 |
| Isolation: | 3000 VDC |
| Power input: | +10 ~ +48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Module, Communication (Programmable) |
| Isolation | |
| Intra-module Isolation | 3000 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal ±8 kV Air for Random Point |
| Surge (IEC 61000-4-5) | ±1 kV for Power Line |
| LED Indicators | |
| Status | 1 x Power and Communication |
| Analog Input | |
| Channels | 16 Differential |
| Type | Voltage Current |
| Sensor Type | Thermocouple: J, K, T, E, R, S, B, N, C Voltage: ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V Current: ±20 mA, 0 ~ +20 mA, +4 ~ +20 mA (requires an optional external 125 Ω resistor) |
| Resolution | 16-bit |
| Accuracy | 0.1% of FSR |
| Sampling Rate | 10 Hz (Total) |
| Input Impedance | > 400 kΩ |
| Common Voltage Protection | 25 VDC |
| Overvoltage Protection | 120 VDC |
| Open Wire Detection | Yes |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Data Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) |
| Protocol | Modbus RTU, DCON |
| Bias Resistor | 10k Ω (DIP switch selectable) |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +48 VDC |
| Consumption | 0.5 W |
| Mechanical | |
| Dimensions (mm) | 31 x 157 x 132 (W x L x H) |
| Installation | DIN-Rail mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +85 °C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.