FCM-MTCP Field Communication Module, Modbus/TCP Slave for iDCS-8000
Field communication module adding Modbus/TCP slave connectivity to the iDCS-8000 system, with 1000 VDC isolation between channels and the backplane bus and RJ-45 10/100Base-T(X) Ethernet.
- Modbus/TCP slave interface for controllers acting as Modbus/TCP masters
- Allows up to 4 simultaneous connections
- RJ-45 10/100Base-T(X) Ethernet port
- Two rotary switches for quick IP address (ID) configuration
- Status LEDs: Run, HF, RF, Link and Act
- 1000 VDC isolation between channels and backplane bus
436,00 EUR per piece
| 1–9 pcs | 436,00 EUR | |
|---|---|---|
| 10–30 pcs | 423,00 EUR | −3 % |
| 31+ pcs | 414,00 EUR | −5 % |
Informații despre produs "FCM-MTCP Field Communication Module, Modbus/TCP Slave for iDCS-8000"
The FCM-MTCP CR is a communication module for the iDCS-8000 system that provides a Modbus/TCP slave interface. It is intended for PLCs and controllers that operate as Modbus/TCP masters, allowing them to communicate with the iDCS-8000 system over Ethernet.
Local LED indicators show system diagnostic and Ethernet connection status. Two rotary switches are provided for quick configuration of the ID (IP address) when several FCM-MTCP modules are installed. The module supports up to 4 simultaneous Modbus/TCP connections.
The module offers 1000 VDC isolation between the channels and the backplane bus, so a high voltage or current fault on a channel should not affect the backplane, other modules or the control unit. It is rated for an operating temperature of -25 ~ +75 °C and is CE, UKCA, FCC, RoHS and WEEE certified.
Applications
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
| Product type: | Communication module |
|---|---|
| Interface: | Ethernet |
| Protocol: | Modbus/TCP |
| Ports: | RJ-45 |
| Isolation: | 1000 VDC |
| Operating temperature: | -25 ~ +75 °C |
Specifications
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | Yes |
| ESD (IEC 61000-4-2) | Yes |
| LED Indicators | |
| Status | 1 x Run, 1 x HF, 1 x RF, 1 x Link, 1 x Act |
| Ethernet | |
| Ports | RJ-45, 10/100Base-T(X) |
| Protocol | Modbus/TCP slave (Allow 4 connection access simultaneously) |
| Power | |
| Consumption | 2.1 W @ 24 VDC Max. |
| Mechanical | |
| Dimensions (mm) | 30 x 85 x 115 |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Humidity | 5 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.