CL-211-WF IAQ Data Logger Module, PM2.5/CO/Temp/Humidity, Wi-Fi
Wi-Fi, Ethernet and RS-485 IAQ logger for PM2.5, CO, temperature, humidity and dew point, with up to 450,000 timestamped records and a relay output.
- Measures PM2.5, CO, temperature, humidity and dew point
- Logs up to 450,000 records with date and time stamps
- RS-485, Ethernet and Wi-Fi interfaces
- DCON, Modbus RTU, Modbus TCP and MQTT (Ethernet) protocol support
- 1 x Form A relay output, 30 VDC or 250 VAC @ 16 A
- Redundant power: PoE (IEEE 802.3af, Class 1) or +12 ~ +48 VDC
435,00 € per piece
| 1–9 pcs | 435,00 € | |
|---|---|---|
| 10–30 pcs | 421,00 € | −3 % |
| 31+ pcs | 413,00 € | −5 % |
Informacje dot. produktu "CL-211-WF IAQ Data Logger Module, PM2.5/CO/Temp/Humidity, Wi-Fi"
CL-211-WF CR is an indoor air quality data logger module that measures PM2.5, CO, temperature, humidity and dew point. It stores up to 450,000 records with date and time stamps, so engineers can review environmental history as well as live readings.
The module offers three communication routes: RS-485, Ethernet and Wi-Fi (IEEE 802.11b/g/n). It supports DCON and Modbus RTU on RS-485, Modbus TCP on Ethernet and Wi-Fi, and MQTT on the Ethernet interface, which makes it straightforward to add to an existing HMI, SCADA or distributed control system. Wi-Fi can operate in Infrastructure or Limited AP mode.
A Form A relay output can drive an alarm or control an IAQ device. Power can come from PoE (IEEE 802.3af, Class 1) or a +12 ~ +48 VDC terminal block, and the module can be ceiling or wall mounted. A PC utility and iOS and Android apps are included for configuration, monitoring and log export to CSV.
Applications
- Transportation of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Blood stations and pharmacies
- Building and energy management
- Warehouse management
- Museums, archives and galleries
- Indoor or underground parking lot air quality monitoring
| Product type: | IAQ data logger module |
|---|---|
| Interface: | Ethernet, RS-485, Wi-Fi |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | 1 |
| Ports: | 2 |
| PoE: | IEEE 802.3af, Class 1 |
| Power input: | PoE, +12 ~ +48 VDC |
| Operating temperature: | 0 ~ 50 °C |
| Mounting: | Ceiling/Wall |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module (2.3 seconds), Communication (Programmable) |
| System | |
| Security | IP filter (whitelist) and Password (web) |
| Alarm | CO |
| Real Time Clock | Yes |
| Data Logger | Yes, up to 450,000 records |
| Temperature Measurement | |
| Range | -10 ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Humidity Measurement | |
| Range | 0 ~ 100% RH, Non-condensing |
| Resolution | 0.1% RH, Non-condensing |
| Accuracy | ±5% RH, Non-condensing |
| Dew Point | |
| Range | Calculated using temperature and relative humidity |
| Resolution | 0.1°C |
| CO Measurement | |
| Range | 0 to 1000 ppm (Electrochemical) |
| Resolution | 1 ppm |
| Accuracy | ±5% of measured value |
| Response Time | 30 seconds |
| Warm-up Time | 5 minutes |
| PM2.5 Measurement | |
| Range | 0 ~ 400 μg/m3 |
| Resolution | 1μg/m3 |
| Response Time | <= 1 min. |
| Wi-Fi | |
| Transmission Distance (LoS) | 50 meters (LOS) |
| Standard Supported | IEEE 802.11 b/g/n |
| RX Sensitivity | -95.7 dBm @ 1 DSSS, -74.0 dBm @ 54 OFDM |
| Output Power | 18 dBm @ 1 DSSS, 14.5 dBm @ 54 OFDM |
| Mode | Infrastructure & Limited AP |
| Encryption | WEP, WPA and WPA2 |
| Antenna | 1 dBi (PCB Antenna) |
| Relay Output | |
| Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet |
| Baud Rate | 1200 ~ 115200 bps |
| Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP (Ethernet, Wi-Fi) MQTT (Ethernet) |
| Power | |
| Consumption | Non-PoE: 2.8 W (Max.) PoE: 2.9 W (Max.) |
| Powered from Terminal Block | +12 ~ +48 VDC |
| Mechanical | |
| Dimensions (mm) | Ø 150 x 53 (Ø x H) |
| Installation | Ceiling Mounting/Wall Mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ 50°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.