uPAC-7186EXD-MTCP-G Programmable Modbus TCP to RTU Gateway, 80186 CPU
Palm-sized programmable gateway that links RS-232/485 serial devices to Ethernet networks and converts Modbus TCP to Modbus RTU, running on built-in MiniOS7 firmware.
- Modbus TCP to RTU gateway for connecting SCADA and HMI systems to serial devices
- One RS-232 and one RS-485 port, with serial rates up to 115200 bps
- Built-in MiniOS7 with a C language development toolkit and Modbus libraries
- 80186 CPU at 80 MHz with 512 KB flash and 512 KB SRAM
- 5-digit 7-segment LED display and programmable LED indicator
- I/O expansion bus interface for one X-board
310,00 € per piece
| 1–9 pcs | 310,00 € | |
|---|---|---|
| 10–30 pcs | 301,00 € | −3 % |
| 31+ pcs | 295,00 € | −5 % |
Info sui prodotti "uPAC-7186EXD-MTCP-G Programmable Modbus TCP to RTU Gateway, 80186 CPU"
uPAC-7186EXD-MTCP-G is a palm-sized programmable device server that brings serial equipment onto an Ethernet network. It acts as a Modbus TCP to RTU gateway, so SCADA and HMI systems that speak Modbus TCP can reach RTU-based devices on its RS-232 and RS-485 ports without custom communication code.
The unit runs the MiniOS7 operating system and can be programmed in C using the supplied development toolkit, which includes Modbus libraries. Engineers can add their own logic to handle serial protocols or data processing directly on the gateway. A single-board I/O expansion bus is also provided for adding analogue or digital I/O.
This gray-cover variant includes a 5-digit 7-segment LED display and a programmable status LED for local diagnostics. Its 10 to 30 VDC supply, DIN-rail mounting and -25 to +75 °C operating range suit control cabinet installations.
Applications
- Connecting Modbus RTU serial devices to Modbus TCP SCADA or HMI systems
- Incorporating serial devices into Ethernet and Internet communication networks
- Serial-to-Ethernet device server for RS-232 and RS-485 equipment
- Integrating serial devices with SCADA packages such as Indusoft, iFix and Citect
| Product type: | Gateway |
|---|---|
| Interface: | Ethernet, RS-232, RS-485 |
| Protocol: | Modbus TCP |
| Ports: | 1 x RJ-45, 1 x RS-232, 1 x RS-485 |
| Power input: | +10 ~ 30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| Software | |
|---|---|
| OS | MiniOS7 |
| Development | C Language |
| CPU Module | |
| CPU | 80186, 80 MHz or compatible |
| 64-bit Hardware Serial Number | Yes |
| EEPROM | 16 KB |
| Flash | 512 KB |
| NVRAM | 31 Bytes |
| SRAM | 512 KB |
| Real Time Clock | Provide seconds, minutes, hours, day of week, month, year |
| Watchdog Timer | Yes |
| Display | |
| Type | 5 x Digit 7 Segment LED Display |
| LED Indicators | |
| Status | 1 x System |
| I/O Expansion | |
| I/O Type | X-board |
| Ethernet | |
| Ports | 1 x RJ-45, 10/100 Base-TX |
| COM Ports | |
| Ports | 1 x RS-232, 1 x RS-485 |
| Baud Rate | 115200 bps Max. |
| Power | |
| Input Range | +10 ~ 30 VDC |
| Consumption | 2.5 W |
| Mechanical | |
| Dimensions (mm) | 72 x 123 x 33 (W x H x D) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +80 °C |
| Humidity | 5 ~ 90 %, Non-condensing |