I-7188EXD-MTCP Programmable Modbus TCP to RTU Gateway, Blue Cover
Palm-sized programmable device server that links RS-232/RS-485 serial devices to Ethernet and acts as a Modbus TCP to RTU gateway for SCADA and HMI systems.
- Modbus TCP to RTU gateway for SCADA and HMI connectivity
- Serial-to-Ethernet device server with RS-232 and RS-485 ports
- 10 Base-T Ethernet (RJ-45) with NE2000-compatible interface
- Programmable in C using XServer and Modbus libraries
- 80188 CPU at 40 MHz, 512 KB flash and 512 KB SRAM
- I/O expansion bus supporting one X-board
303,00 € per piece
| 1–9 pcs | 303,00 € | |
|---|---|---|
| 10–30 pcs | 294,00 € | −3 % |
| 31+ pcs | 288,00 € | −5 % |
Info sui prodotti "I-7188EXD-MTCP Programmable Modbus TCP to RTU Gateway, Blue Cover"
The I-7188EXD-MTCP is a programmable serial-to-Ethernet device server with one RS-232 and one RS-485 port, bridging serial equipment onto a 10 Base-T network. It also works as a Modbus TCP to RTU gateway, so SCADA and HMI software using Modbus TCP can communicate with serial Modbus devices.
ICP DAS supplies XServer and Modbus libraries in C for building custom applications. These tools let engineers bring serial devices onto Ethernet and Internet communication and use the standard Modbus protocol with SCADA packages. The manufacturer cites Indusoft, ISaGRAF, DasyLab, Trace Mode, Citect and iFix as examples.
Hardware is built around an 80188 CPU at 40 MHz with 512 KB flash and 512 KB SRAM, plus a real-time clock, watchdog timer and a 5-digit 7-segment LED display. An I/O expansion bus supports one X-board, with a range of more than 50 boards offering A/D, D/A, D/I, D/O and serial functions. This blue-cover CR variant is supplied with the same specification as the standard model.
Applications
- Connecting RS-232/RS-485 devices to Ethernet networks
- Modbus TCP to RTU gateway for SCADA and HMI systems
- Adding A/D, D/A, D/I, D/O or serial I/O through a single expansion board
| Product type: | Programmable Modbus gateway |
|---|---|
| Interface: | Ethernet, RS-232, RS-485 |
| Protocol: | Modbus TCP |
| Ports: | 3 |
| Power input: | +10 ~ 30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
| Housing: | Palm-sized |
Specifications
| CPU Module | |
|---|---|
| CPU | 80188, 40 MHz or compatible |
| 64-bit Hardware Serial Number | Yes |
| EEPROM | 2 KB |
| Flash | 512 KB |
| NVRAM | 31 Bytes |
| SRAM | 512 KB |
| Real Time Clock | Provide seconds, minutes, hours, day of week, month, year |
| Watchdog Timer | Yes |
| Display | |
| Type | 5 x Digit 7 Segment LED Display |
| LED Indicators | |
| Status | 1 x System |
| I/O Expansion | |
| I/O Type | X-board |
| Ethernet | |
| Ports | 1 x RJ-45, 10 Base-T |
| COM Ports | |
| Ports | 1 x RS-232, 1 x RS-485 |
| Baud Rate | 115200 bps Max. |
| Power | |
| Input Range | +10 ~ 30 VDC |
| Consumption | 3.0 W |
| Mechanical | |
| Dimensions (mm) | 72 x 123 x 33 (W x H x D) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +80 °C |
| Humidity | 5 ~ 90 %, Non-condensing |
Specifications as published by the manufacturer. Subject to change.