CL-202-WF CO2/Temperature/Humidity/Dew Point Data Logger Module with Wi-Fi
IAQ data logger for CO2, temperature, humidity and dew point, with RS-485, Ethernet PoE and Wi-Fi interfaces, DCON, Modbus RTU/TCP and MQTT support.
- NDIR CO2 sensor measuring 0 to 9999 ppm, with temperature and humidity measurement and dew point
- Up to 450,000 time-stamped records stored on board for download
- RS-485, Ethernet and Wi-Fi (IEEE 802.11 b/g/n) communication interfaces
- DCON, Modbus RTU, Modbus TCP and MQTT (Ethernet) protocol support
- 1 x Form A relay output for alarm or IAQ device control
- Redundant PoE (IEEE 802.3af, Class 1) and +12 ~ +48 VDC power inputs
414,00 € per piece
| 1–9 pcs | 414,00 € | |
|---|---|---|
| 10–30 pcs | 402,00 € | −3 % |
| 31+ pcs | 393,00 € | −5 % |
Info sui prodotti "CL-202-WF CO2/Temperature/Humidity/Dew Point Data Logger Module with Wi-Fi"
The CL-202-WF CR is an indoor air quality monitoring data logger that records CO2, temperature, humidity and dew point readings with date and time stamps. Its NDIR CO2 sensor covers 0 to 9999 ppm, and the module stores up to 450,000 downloadable records for later analysis.
Engineers can connect the module over RS-485, Ethernet or Wi-Fi and integrate it into existing HMI or SCADA systems using DCON, Modbus RTU or Modbus TCP. On the Ethernet interface, MQTT is also supported. A relay output can be used for alarm signalling or to control IAQ equipment, and the module can be powered from PoE (IEEE 802.3af, Class 1) or a +12 ~ +48 VDC terminal block input.
Configuration, real-time monitoring and log export are handled by the iAir Utility, with iOS and Android apps also included. The module can be ceiling or wall mounted.
- Monitors CO2, temperature, humidity and dew point, with alarm functions for CO2, RH and temperature
- NDIR CO2 sensor with 0 to 9999 ppm range and 1 ppm resolution
- Up to 450,000 time-stamped records stored on board
- RS-485, Ethernet and IEEE 802.11 b/g/n Wi-Fi interfaces, with Infrastructure and Limited AP modes
- DCON, Modbus RTU, Modbus TCP and MQTT (Ethernet) protocol support
- Relay output (1 x Form A) for alarm or IAQ device control
- Redundant PoE and DC power inputs
Applications
- Transportation of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Blood stations and pharmacies
- Building and energy management
- Warehouse management
- Museums, archives and galleries
- HCHO/VOC detection
- Indoor or underground parking lot air quality monitoring
| Product type: | Data logger module |
|---|---|
| Interface: | Ethernet, RS-485, Wi-Fi |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | 1 |
| Ports: | 2 |
| PoE: | IEEE 802.3af, Class 1 |
| Power input: | +12 ~ +48 VDC |
| Operating temperature: | 0 ~ 50 °C |
| Mounting: | Ceiling, wall |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module (2.3 seconds), Communication (Programmable) |
| System | |
| Security | IP filter (whitelist) and Password (web) |
| Alarm | CO2/RH/Temperature |
| Real Time Clock | Yes |
| Data Logger | Yes, up to 450,000 records |
| Temperature Measurement | |
| Range | -10 ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Humidity Measurement | |
| Range | 0 ~ 100% RH, Non-condensing |
| Resolution | 0.1% RH, Non-condensing |
| Accuracy | ±5% RH, Non-condensing |
| CO2 Measurement | |
| Range | 0 to 9999 ppm (NDIR) |
| Resolution | 1 ppm |
| Accuracy | ±40 ppm ±3% of measured value |
| Response Time | 120 seconds |
| Warm-up Time | 5 minutes |
| Wi-Fi | |
| Transmission Distance (LoS) | 50 meters (LOS) |
| Standard Supported | IEEE 802.11 b/g/n |
| RX Sensitivity | -95.7 dBm @ 1 DSSS, -74.0 dBm @ 54 OFDM |
| Output Power | 18 dBm @ 1 DSSS, 14.5 dBm @ 54 OFDM |
| Mode | Infrastructure & Limited AP |
| Encryption | WEP, WPA and WPA2 |
| Antenna | 1 dBi (PCB Antenna) |
| Relay Output | |
| Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet |
| Baud Rate | 1200 ~ 115200 bps |
| Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP (Ethernet, Wi-Fi) MQTT (Ethernet) |
| Power | |
| Consumption | Non-PoE: 1.6 W (Max.) PoE: 1.7 W (Max.) |
| Powered from Terminal Block | +12 ~ +48 VDC |
| Mechanical | |
| Dimensions (mm) | Ø 150 x 53 (Ø x H) |
| Installation | Ceiling Mounting/Wall Mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ 50°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.