Gateways
The DGW-521 CR is a DIN-rail gateway that lets a host PC, PAC or TouchPAD control DALI lighting devices over serial or USB. It accepts Modbus RTU and DCON from RS-232, RS-485 or USB and translates them to DALI, so existing serial-based control software can address a DALI lighting network without a separate DALI controller.A built-in DALI power supply (16 VDC ±5%, maximum 250 mA) can be switched on or off, which suits installations where the DALI bus is already powered elsewhere. The ID code can be set over the RS-485 interface, which simplifies commissioning. DALI isolation is rated at 1500 VDC.The gateway is intended for DALI lighting systems covering small areas. DALI signal cables must not exceed 300 m. The unit carries CE, UKCA, FCC, RoHS and WEEE marks. The USB driver is listed for Windows XP and Windows 7 only.ApplicationsLighting control for small DALI installationsHost PC, PAC or TouchPAD access to DALI devicesSerial-to-DALI integration in building automation
The GW-2212i bridges Modbus TCP hosts and serial Modbus RTU/ASCII devices, so legacy serial equipment can be reached over an Ethernet network without the cable length limits of a direct serial connection. It supports Modbus TCP/UDP and Modbus RTU/ASCII in both master and slave roles, with up to 32 TCP masters per serial port.Beyond protocol conversion, the unit can run as a serial bridge, serial tunnel or pair-connection, routing data over TCP/IP between two serial Modbus devices. A read-cache stores previous requests and responses so repeated polls to the same slave are answered immediately, reducing load on the serial port and improving response times. Two Ethernet ports allow daisy-chaining, and the module can be powered over PoE (IEEE 802.3af, Class 1) or from a DC terminal block.The GW-2212i is configured through its built-in web server, which supports static IP or DHCP addressing and the serial port settings. A dual watchdog (CPU and host) is provided to keep the module running and recover from firmware faults or loss of communication with the host. It is DIN-rail mounted and carries RoHS compliance.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
GW-2215i CR is a DIN-rail Modbus gateway that lets a Modbus TCP host reach serial Modbus RTU or ASCII devices across an Ethernet network, removing the cable length limits of legacy serial links. It can act as master or slave on both the TCP/UDP and the RTU/ASCII side, and it supports up to 32 TCP masters per serial port.The built-in read cache stores recent requests and responses in the module's memory. When several SCADA or HMI masters poll the same slave, the cached reply is returned immediately, which reduces traffic on the serial bus and shortens TCP response times. Two Ethernet ports allow daisy-chaining, and the unit can be set to a static IP or DHCP through its web interface.Power can come from a PoE switch (IEEE 802.3af, Class 1) or from a +12 ~ 48 VDC terminal block. The single RS-422/485 port is isolated, with 3000 VDC signal isolation, and the module operates from -25 ~ +75 °C. The ordering code GW-2215i CR is the RoHS-compliant variant listed in this shop.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The GW-2222i is a Modbus TCP to RTU/ASCII gateway for connecting a Modbus TCP host to serial Modbus RTU or ASCII devices over Ethernet. It removes the cable length restrictions of legacy serial links, so existing serial instruments can be integrated into networked SCADA and supervisory systems without adding Ethernet capability to each device.Two Ethernet ports allow daisy-chain wiring, which simplifies device placement and cuts switch infrastructure. The unit can also run in pair-connection, serial-bridge or serial-tunnel modes, routing data over TCP/IP between two serial Modbus devices. Power can come from PoE (IEEE 802.3af, Class 1) or a DC terminal block supplying +12 ~ 48 VDC.A read-cache stores previous requests and responses, so repeated queries from multiple masters are answered immediately. This reduces load on the serial ports and improves response times and overall system stability. Configuration is handled through the built-in web server, which supports static IP or DHCP addressing.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The GW-2225i CR is a Modbus TCP to RTU/ASCII gateway that lets a Modbus TCP host communicate with serial Modbus RTU or ASCII devices over Ethernet. Serial devices are no longer limited by the cable lengths of legacy RS-422/485 wiring, which simplifies SCADA and supervisory architectures where field devices lack Ethernet capability.Beyond host-to-device gatewaying, the unit can be configured as a pair-connection, serial-bridge or serial-tunnel, routing data over TCP/IP between two serial Modbus RTU/ASCII devices. A read-cache stores previous requests and responses, so repeated queries from several HMI or SCADA masters to the same slave are answered immediately, reducing serial bus loading. Two Ethernet ports allow daisy-chaining, and the unit can be powered via PoE (IEEE 802.3af, Class 1) or a +12 ~ 48 VDC terminal block.The GW-2225i CR suits factory and building automation, remote diagnosis and management, and solar monitoring. Its dual watchdog, with separate CPU and host watchdogs, resets the processor if the firmware misbehaves or if host communication stops for a predefined timeout. The built-in web server provides configuration of DHCP or static addressing, gateway and mask settings, and serial port parameters.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The GW-2232i CR is a Modbus TCP to RTU/ASCII gateway that lets a Modbus TCP host communicate with serial Modbus RTU or ASCII devices over Ethernet, removing the cable length limits of legacy serial networks. It supports Modbus TCP/UDP and Modbus RTU/ASCII in both master and slave roles, with up to 32 TCP connections (masters) per serial port.Beyond simple protocol conversion, the unit can be configured as a pair-connection, serial-bridge or serial-tunnel, routing data over TCP/IP between two serial Modbus devices. Its read-cache stores previous requests and responses, so repeated requests to the same slave can be answered immediately, which reduces serial port loading and speeds up TCP responses. A built-in web server and UDP responder (UDP Search) support configuration and device discovery.Two 10/100 Ethernet ports allow daisy-chain wiring, with PoE (IEEE 802.3af, Class 1) or a 12 ~ 48 VDC terminal block as power sourceThree isolated RS-232 ports with 3000 VDC signal isolation and 1000 VDC power isolationApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The GW-2235i CR bridges Modbus TCP hosts and serial Modbus RTU/ASCII devices over Ethernet, removing the cable length limits of legacy serial networks. It suits SCADA and HMI systems that need to reach serial field devices without native Ethernet capability.Each serial port accepts up to 32 TCP masters, and a read-cache stores previous requests and responses so repeated queries to the same slave are answered immediately. The two Ethernet ports allow daisy-chaining, and the unit can be powered over IEEE 802.3af Class 1 PoE or from a DC terminal block.Isolation is provided on the serial side, with 3000 VDC signal isolation on the RS-422/485 ports. Configuration is handled through the built-in web server, which supports static IP or DHCP addressing and serial port settings. The unit is CE, UKCA, FCC, RoHS and WEEE listed.ApplicationsFactory, building and home automationRemote diagnosis and managementSolar monitoring
GW-2515iM CR is a Modbus TCP to Modbus RTU/ASCII gateway for connecting Ethernet-based supervisory systems to serial field devices on RS-422/485 networks. Its built-in web server, reached through a standard browser over HTTP or HTTPS, lets engineers configure the unit without dedicated software.The two Ethernet ports form a daisy-chain topology, which reduces cabling and switch count. If power is lost on a module, the LAN bypass engages automatically so Ethernet traffic continues through the chain. Security options include Modbus/TCP Security, HTTPS, SNMPv3 and IP address filtering to allow or block specific hosts.The unit has a metal DIN-rail housing and accepts either a +12 ~ 48 VDC terminal-block supply or PoE (IEEE 802.3af, Class 2), with an operating range of -25 ~ +75 °C.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
GW-2525iM CR bridges Ethernet-based Modbus TCP clients and serial Modbus RTU or ASCII devices. It suits engineers who need to bring existing RS-422/485 equipment onto a TCP network without changing the field devices, while adding security features such as HTTPS, SNMPv3 and an IP address filter.The built-in dual-port Ethernet switch lets units be wired in a daisy chain, reducing cabling and switch count. If power is lost, the LAN bypass engages so Ethernet communication along the chain is maintained. The module can be configured through a standard web browser, with user authentication and encrypted HTTPS access.Both RS-422/485 ports are isolated, with 1000 VDC power isolation and 3000 VDC signal isolation. The unit accepts PoE (IEEE 802.3af, Class 2) or a +12 ~ 48 VDC terminal block supply and mounts on a DIN rail in a metal housing.ApplicationsFactory, building and home automationRemote diagnosis and managementSolar monitoring
The GW-2535iM CR converts Modbus TCP traffic into Modbus RTU or ASCII for serial field devices. It suits engineers who need to bring legacy RS-422/485 equipment onto an Ethernet network while adding security features such as Modbus/TCP Security, HTTPS and SNMPv3.The dual-port Ethernet switch allows devices to be wired in a daisy chain, reducing cabling and switch requirements. If power is lost, LAN bypass keeps Ethernet communication running through the chain. The built-in web server lets you configure the unit from a standard browser, and IP address filtering can allow or block specific hosts.Three isolated RS-422/485 ports provide 1000 VDC power isolation and 3000 VDC signal isolation, with speeds up to 115200 bps. The unit can be powered by PoE (IEEE 802.3af, Class 2) or by a +12 ~ 48 VDC terminal block, and it mounts on a DIN rail for control cabinet installation.ApplicationsFactory, Building and Home AutomationRemote Diagnosis and ManagementSolar Monitoring
The I-7188E2-MTCP is a palm-sized programmable gateway for bringing serial equipment onto an Ethernet network. It bridges an RS-232 port and an RS-485 port to a 10BASE-T connection, so engineers can expose legacy serial devices to Modbus TCP clients without redesigning the field hardware.Built around an 80188-40 CPU with 384 KB SRAM and 512 KB Flash, the unit runs the built-in MiniOS7 and Modbus firmware. Application code can be written in C using the supplied software development tool kits, including XServer and Modbus libraries.This ordering code is the blue cover version. It mounts on a DIN rail and operates from a +10 ~ 30 VDC supply across an operating temperature range of -25 ~ +75 °C.ApplicationsIntegrating RS-232/RS-485 devices into Ethernet networksModbus TCP to RTU gateway for SCADA and HMI communicationConnecting serial equipment to SCADA packages such as Indusoft, ISaGARF, DasyLab, Trace Mode, Citect and iFix
The I-7188E2D-MTCP CR is a palm-sized programmable device server that brings serial equipment onto Ethernet. It provides one RS-232 and one RS-485 port on the serial side and a 10BASE-T RJ-45 connection on the network side, so existing field devices can be reached over an Ethernet network without replacing them.Beyond simple serial-to-Ethernet bridging, the unit operates as a Modbus TCP to RTU gateway, allowing SCADA and HMI software that speaks Modbus TCP to read and write devices on the serial bus. ICP DAS supplies XServer and Modbus libraries, along with C-language development tools, so the behaviour of the unit can be customised for the application. The built-in MiniOS7 runs the programme.The CR ordering variant is supplied with a blue cover and carries an 80188 40 MHz CPU, 384 KB SRAM, 512 KB flash and 2 KB EEPROM. A five-digit 7-segment LED display, a programmable LED indicator and a watchdog timer support on-site status checking and unattended operation. It mounts on a DIN rail and accepts a +10 to 30 VDC supply.ApplicationsConnecting serial RS-232/RS-485 devices to Ethernet networksProviding Modbus TCP access to Modbus RTU devices for SCADA and HMI systemsIntegrating serial devices with SCADA packages such as Indusoft, DasyLab and iFix
The I-7188E2D-MTCP-G is a programmable gateway that brings serial devices onto Ethernet. It offers one 10BASE-T RJ-45 port alongside RS-232 and RS-485 serial ports, and can act as a Modbus TCP to RTU gateway so that Modbus TCP clients such as SCADA and HMI software can reach RTU-based equipment.Built around an 80188-40 CPU with 512 KB flash and 384 KB SRAM, the unit runs ICP DAS MiniOS7 and is programmed in C using the supplied software development tool kit. XServer and Modbus libraries are provided for building custom serial-to-Ethernet logic, with a 5-digit 7-segment LED display, a programmable LED indicator and a built-in watchdog timer for status and reliability.The -G suffix identifies the gray cover version. The unit is specified for a +10 to 30 VDC supply, -25 to +75 °C operation and DIN-rail mounting in a compact 72 x 112 x 33 mm housing.ApplicationsIntegrating serial devices into Ethernet networksModbus TCP to RTU gateway for SCADA and HMI systemsCommunication with SCADA software such as Indusoft, DasyLab, Trace Mode, Citect and iFix
The I-7188EX-MTCP is a palm-sized programmable device server that connects RS-232 and RS-485 serial devices to an Ethernet network. It also acts as a Modbus TCP to RTU gateway, so SCADA and HMI software that speaks Modbus TCP can reach serial field devices without custom drivers.Engineers can extend the unit with the included C language development toolkit, which provides XServer and Modbus libraries, running on the MiniOS7 operating system. The ordering code I-7188EX-MTCP CR is the blue-cover version of this gateway.Hardware features include an 80188-40 CPU, 512 KB flash and 512 KB SRAM, a real-time clock, a watchdog timer and a 64-bit hardware serial number. An I/O expansion bus accepts one X-board for added analogue or digital I/O or serial ports.ApplicationsIncorporating serial RS-232/RS-485 devices into Ethernet networksModbus TCP access to serial Modbus RTU devices for SCADA and HMI systemsSerial device integration with SCADA packages such as Indusoft, ISaGRAF, DASYLab, Trace Mode, Citect and iFix
The I-7188EXD-MTCP is a programmable serial-to-Ethernet device server with one RS-232 and one RS-485 port, bridging serial equipment onto a 10 Base-T network. It also works as a Modbus TCP to RTU gateway, so SCADA and HMI software using Modbus TCP can communicate with serial Modbus devices.ICP DAS supplies XServer and Modbus libraries in C for building custom applications. These tools let engineers bring serial devices onto Ethernet and Internet communication and use the standard Modbus protocol with SCADA packages. The manufacturer cites Indusoft, ISaGRAF, DasyLab, Trace Mode, Citect and iFix as examples.Hardware is built around an 80188 CPU at 40 MHz with 512 KB flash and 512 KB SRAM, plus a real-time clock, watchdog timer and a 5-digit 7-segment LED display. An I/O expansion bus supports one X-board, with a range of more than 50 boards offering A/D, D/A, D/I, D/O and serial functions. This blue-cover CR variant is supplied with the same specification as the standard model.ApplicationsConnecting RS-232/RS-485 devices to Ethernet networksModbus TCP to RTU gateway for SCADA and HMI systemsAdding A/D, D/A, D/I, D/O or serial I/O through a single expansion board
The tGW-712 CR bridges Modbus TCP hosts and serial Modbus RTU/ASCII devices, so a supervisory system on an Ethernet network can reach equipment that only has a serial interface. This variant provides one 5-wire RS-232 port on a male DB-9 connector, which keeps wiring simple for point-to-point connections.Beyond simple protocol conversion, the gateway can be configured as a pair-connection, serial-bridge or serial-tunnel device, routing data over TCP/IP between two serial Modbus devices. A read-cache stores previous requests and responses in the module's memory buffer, returning repeated answers immediately to reduce traffic on the serial side and speed up TCP responses.Power can be supplied over Ethernet using IEEE 802.3af Class 1 PoE from a compatible switch, or from a +12 ~ 48 VDC terminal block where no PoE is available. The unit is designed for low power consumption, rated at 0.07 A @ 24 VDC, and mounts on a DIN rail in a plastic housing.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The tGW-712i bridges Ethernet-based Modbus TCP/UDP masters and legacy serial Modbus RTU/ASCII devices, so serial equipment can be reached over an IP network without the cable length limits of RS-232 connections. It can also pair two serial Modbus devices across TCP/IP, which suits equipment that has no Ethernet capability of its own.A read-cache stores previous requests and responses in the module's memory. When several masters poll the same slave device with identical requests, the cached reply is returned immediately, which reduces traffic on the serial bus and shortens TCP response times.The unit can be powered over Ethernet from an IEEE 802.3af, Class 1 PoE switch, or from a +12 ~ 48 VDC supply on the terminal block. Configuration is handled through a built-in HTTP web server, and the order includes a DC-jack to 2-wire power cable, 0.3 M.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
tGW-715 CR bridges Modbus TCP/UDP hosts on an Ethernet network with serial Modbus RTU or ASCII devices on RS-422/485. It lets a supervisory system reach field devices without being limited by the cable lengths of legacy serial links, and it can act as master or slave on either side of the conversion.The gateway can also be used in pair-connection, serial-bridge or serial-tunnel arrangements, routing serial Modbus data over TCP/IP between two RTU or ASCII devices. A read-cache stores previous requests and responses, so repeated queries from several HMI or SCADA masters to the same slave are answered quickly, reducing traffic on the RS-485 bus.Power can be supplied over Ethernet via IEEE 802.3af Class 1 PoE, or from a +12 ~ 48 VDC terminal block input where no PoE switch is available. The listing includes a DC-jack to 2-wire power cable, 0.3 M. The unit is housed in a plastic case for DIN-rail mounting and is rated for -25 ~ +75 °C operation.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The tGW-715-T CR is a compact gateway that lets Modbus TCP and UDP masters communicate with serial Modbus RTU and ASCII devices over Ethernet. It is a practical way to bring legacy serial equipment into an Ethernet-based SCADA or HMI system without being limited by serial cable length.The gateway can also be set up for pair-connection, serial-bridge or serial-tunnel applications, routing Modbus data over TCP/IP between two serial devices. This suits mainframes, servers or other serial equipment that uses Modbus RTU or ASCII but has no Ethernet capability of its own.A read-cache stores previous requests and responses, so repeated requests from several masters to the same slave are answered immediately. This reduces traffic on the RS-485 bus and gives faster TCP responses. The -T variant takes its supply from a terminal block rated +12 ~ 48 VDC.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The tGW-715-UL bridges Ethernet-based Modbus TCP masters and serial Modbus RTU/ASCII devices on a single 1-port RS-422/485 interface. It allows legacy serial equipment to be reached over a TCP/IP network, removing the cable-length restrictions of a direct serial connection.Power can be supplied over Ethernet using IEEE 802.3af Class 1 PoE from a compatible switch, or from a +12 ~ 48 VDC terminal block where no PoE switch is available. A read-cache stores previous requests and responses, so repeated polls from several masters to the same slave can be answered quickly, reducing traffic on the RS-485 bus.This ordering code uses the standard, non-isolated RS-422/485 port with an operating range of -25 ~ +70 °C. Choose the tGW-715i-UL variant if the serial port requires 3000 VDC signal isolation, or the -UTA version for operation down to -40 °C.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The tGW-715-UL-UTA CR is a compact gateway that lets a Modbus TCP host communicate with serial Modbus RTU or ASCII devices over Ethernet. Because the serial side is carried over TCP/IP, cable length limits of conventional RS-422/485 wiring no longer restrict where field devices can be placed.This variant is rated for an operating temperature of -40 ~ +70 °C and uses conformal coating for resistance to moisture and salt spray, which suits outdoor-adjacent cabinets and high-humidity sites. It can be powered from a PoE switch (IEEE 802.3af, Class 1) or from a +12 ~ 48 VDC terminal block, and it mounts on DIN-rail.Read-caching stores recent requests and responses, so repeated queries from several SCADA or HMI masters to the same slave are answered faster and place less load on the RS-485 bus. The -CR ordering code includes a DC-jack to 2-wire power cable, 0.3 M (CA-002-UL).ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
tGW-715i CR is a compact gateway that lets a Modbus TCP host talk to serial Modbus RTU or ASCII devices over Ethernet, removing the cable-length limits of legacy serial networks. It suits engineers retrofitting existing RS-485 or RS-422 equipment into an IP-based SCADA or HMI system.The unit can also be set up for pair-connection, serial-bridge or serial-tunnel operation, routing data over TCP/IP between two serial Modbus devices. A read-cache stores recent requests and responses, so repeated queries from several masters to the same slave are answered faster and place less load on the serial bus.Power can come from PoE (IEEE 802.3af, Class 1) or from a +12 ~ 48 VDC terminal-block supply. The 3000 VDC signal isolation on the serial port and the DIN-rail housing make it practical for panel-mounted installations. The ordering code includes a DC-jack to 2-wire power cable, 0.3 M.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The tGW-715i-T CR is a compact Modbus gateway that lets a Modbus TCP or UDP host communicate with serial Modbus RTU or ASCII devices across an Ethernet network. Moving the serial segment onto Ethernet removes the cable length limits of legacy serial links, which suits retrofits and distributed SCADA or HMI architectures.The gateway can also be configured as a serial bridge or tunnel, routing data over TCP/IP between two serial Modbus RTU/ASCII devices. This is useful where the connected equipment has no Ethernet capability of its own. A read-cache stores previous requests and responses, so repeated queries from several masters to the same slave are answered immediately, which reduces traffic on the RS-485 bus.Configuration is handled through the built-in web server over HTTP, with static IP or DHCP addressing and UDP Search for device discovery. Automatic RS-485 direction control and a terminal block connector simplify wiring. The unit draws 0.07 A at 24 VDC and mounts on DIN-rail in a plastic housing.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring
The tGW-715i-UL CR bridges Modbus TCP hosts and serial Modbus RTU or ASCII devices over Ethernet, removing the cable length limits of legacy RS-485 links. It suits engineers who need to bring existing serial instruments or controllers onto a TCP/IP network without changing the field devices.The isolated variant adds 3000 VDC signal isolation on its single RS-422/485 port, which helps protect the serial bus from ground differences between sites. The gateway can also route data between two serial Modbus devices across TCP/IP, supporting pair-connection, serial-bridge and serial-tunnel arrangements. A read-cache stores previous requests and responses, so repeated queries from several masters to the same slave can be answered faster and with less load on the RS-485 bus.Power can come from an IEEE 802.3af Class 1 PoE switch over standard Ethernet cable, or from a +12 ~ 48 VDC terminal block input. The standard operating temperature range is -25 ~ +70 °C. A DC-jack to 2-wire power cable, 0.3 M (CA-002-UL), is included.ApplicationsFactory automationBuilding and home automationRemote diagnosis and managementSolar monitoring