HRT-710-UTA Modbus RTU/ASCII to HART Gateway, -40 to +75 °C
Modbus RTU/ASCII to HART gateway that lets a Modbus master read up to 15 HART devices, such as transmitters and actuators. Rated for -40 to +75 °C operation.
- Modbus RTU and ASCII to HART master gateway with one HART port
- Point-to-point or multi-drop HART operation for up to 15 HART devices
- Supports HART short and long frames and HART burst mode
- Modbus slave mode with RS-232, RS-422 or RS-485 serial interface
- Operating temperature -40 ~ +75 °C for the CR variant
- Built-in watchdog and LED indicators
383,00 EUR per piece
| 1–9 pcs | 383,00 EUR | |
|---|---|---|
| 10–30 pcs | 372,00 EUR | −3 % |
| 31+ pcs | 364,00 EUR | −5 % |
Termékinformációk "HRT-710-UTA Modbus RTU/ASCII to HART Gateway, -40 to +75 °C"
The HRT-710-UTA CR is a HART master to Modbus slave gateway. It lets a Modbus master access HART devices such as transmitters and actuators, so their data can be integrated into an HMI or SCADA system without a separate HART interface on the host.
The gateway supports point-to-point and multi-drop HART topologies with up to 15 HART devices, using short and long frames and HART burst mode. On the serial side it supports Modbus RTU and Modbus ASCII over RS-232, RS-422 or RS-485. Each module presents its HART devices as Modbus slaves, and configuration and HART device diagnosis are handled with the HG_Tool software utility.
The CR ordering code is the variant built for the -40 ℃ application, with an operating range of -40 ~ +75 °C. It mounts on DIN-rail or on a wall in horizontal orientation.
- Suited to integrating HART flow meters and other HART field devices into Modbus networks
Applications
- Industrial automation
- Factory automation
- Process automation
| Product type: | HART gateway |
|---|---|
| Interface: | RS-232 / RS-422 / RS-485 |
| Protocol: | HART, Modbus RTU / Modbus ASCII |
| Ports: | 1 HART |
| Isolation: | UL1577 |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -40 ~ +75 °C |
| Mounting: | DIN-rail / wall |
Specifications
| COM Ports | |
|---|---|
| Ports | RS-232(3 wires) / RS-422 / RS-485 |
| Baud Rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Protocol | Modbus RTU / Modbus ASCII |
| HART | |
| Ports | 1 |
| Device | 2-wired or 4-wired HART devices |
| Topology | Point to Point or Multi-Drop |
| Data | Only Digital Data |
| Frame Type | Short and Long Frame |
| Burst Mode | Supported |
| Max. HART Device | 15 |
| Loop Resistor | 250 Ω (1/4W) by Jumper |
| Isolation | UL1577 Spec. |
| Protocol | 2-pin screwed terminal block |
| Loop Power | No |
| Power | |
| Reverse Polarity Protection | Power reverse polarity protection, Over-voltage brown-out protection |
| Input Range | Unregulated +10 ~ +30 VDC |
| Consumption | 1 W |
| Mechanical | |
| Dimensions (mm) | 72 x 35 x 121 (W x L x H) Detail |
| Installation | DIN-Rail or Wall Mounting (Horizontal) |
| Environment | |
| Operating Temperature | -40 ~ +75 °C |
| Storage Temperature | -40 ~ +80 °C |
| Humidity | 10% ~ 90% RH, Non-condensing |