LC-101H Lighting Control Module, 1-CH, 0-5 A AC Load Current Measurement
Single-channel lighting control module with a Form C relay, one wet-contact digital input and 0-5 A AC load current measurement, switched over RS-485 or by physical switches.
- Remote on/off control of the lighting circuit over RS-485, plus local control via a physical switch
- Form C relay output that supports dual-loop designs with physical switches
- AC load current measurement from 0 to 5 A, read back over RS-485 with 3% of FSR accuracy
- Current readback can be used to detect faulty lights and confirm the on/off state of the dual-loop
- Relay designed to withstand inductive inrush currents, with 100,000 electrical operations rated
- Modbus RTU/DCON protocol with 1200 to 115200 bps software-configurable baud rate
66,00 € per piece
| 1–9 pcs | 66,00 € | |
|---|---|---|
| 10–30 pcs | 64,00 € | −3 % |
| 31+ pcs | 63,00 € | −5 % |
Informations sur le produit "LC-101H Lighting Control Module, 1-CH, 0-5 A AC Load Current Measurement"
The LC-101H CR is a single-loop lighting control module for smart home and building lighting circuits. Each circuit can be switched on or off remotely over RS-485, locally through a physical switch, or with both methods used separately or combined.
The module measures the AC load current on the lighting circuit in the 0 to 5 A range, so the controller can read back the current value over RS-485. This helps identify faulty lights and shows whether the circuit is on or off. The high-power relay is designed to withstand the inrush currents that inductive lighting loads produce when switched, which helps protect the relay and reduce maintenance.
No software is needed for basic channel control. When software control is required, the module communicates using Modbus RTU, with the RS-485 address set by hardware.
Applications
- Smart home lighting control
- Building automation lighting circuits
- Remote switching and status monitoring of lighting loads
| Product type: | Lighting control module |
|---|---|
| Interface: | RS-485 |
| Protocol: | Modbus RTU/DCON |
| Digital inputs: | 1 |
| Relay outputs: | 1 |
| Analog inputs: | 1 (AC current) |
| Ports: | 1 |
| Isolation: | 3000 VDC |
| Power input: | 10 ~ 30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| Software | |
|---|---|
| Function | Local and Remote Direct Control Relay ON/OFF and Remote Status Monitoring |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal |
| Surge (IEC 61000-4-5) | ±2 kV for Power |
| LED Indicators | |
| Status | 1 LED as Power Indicator |
| Digital Input | |
| Channels | 1 |
| Type | Wet Contact, 90 ~ 240 VAC |
| ON Voltage Level | 65 VAC |
| OFF Voltage Level | 56 VAC |
| Isolation | 3000 VDC |
| Input Impedance | 68 KΩ, 2W |
| Relay Output | |
| Channels | 1 |
| Type | Power Relay, Form C (SPDT N.O+N.C..) |
| Contact Rating | 30 A @ 250 VAC |
| AC Load Current Measurement | Yes, 0 ~ 5 A range with 3% of FSR Accuracy. |
| Operate Time | 15 ms Max |
| Release Time | 22 ms Max. |
| Electrical Endurance | 100,000 ops. |
| Mechanical Endurance | 10,000,000 ops |
| Power on Value | Yes |
| Safe Value | Yes |
| Application Specification | (1).Incandescent Lamp: 40W/ 220VAC * 5 Sets (2).LED(Electronic ballast): 40W/ 220VAC *8 Sets |
| Ethernet | |
| Node Address | 32 to 63 for hardware configuration |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | Hardware Configuration: Fixed 9600 bps Software Configuration: 1200 to 115200 bps |
| Data Format | N,8,1/O,8,1/E,8,1/N,8,2 |
| Protocol | Modbus RTU/DCON |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | 10 ~ 30 VDC |
| Consumption | 1.9 W Max. |
| Mechanical | |
| Dimensions (mm) | 72 mm x 95 mm x 57 mm |
| Installation | DIN-Rail |
| Environment | |
| Operating Temperature | -25 ~ +75°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.