DNP-211-S DNP3 Slave to Modbus TCP Client Gateway
DNP3 outstation gateway that presents up to 32 Modbus TCP slaves as a single DNP3 slave for SCADA master stations and RTUs.
- Integrates up to 32 Modbus TCP slaves into one DNP3 slave
- DNP3 connectivity over RS-485, TCP/IP or UDP
- Modbus TCP function codes 1, 2, 3, 4, 5, 6, 15 and 16
- DNP3 data groups 1, 10, 11, 30, 40 and 41
- Analog data in word, int32, float and double formats
- Configurable data point mapping via DNP-211-S utility software
This item is quoted per order. Send us your quantity and we reply with price and delivery time.
Request a quote
Plus disponible
Informations sur le produit "DNP-211-S DNP3 Slave to Modbus TCP Client Gateway"
DNP-211-S bridges Modbus TCP field devices and DNP3 master stations. It polls several Modbus TCP servers and exposes their data as one DNP3 outstation, so a master station can read and control the underlying devices without needing a native Modbus driver.
The gateway accepts DNP3 over RS-485, TCP/IP or UDP and supports Binary, Binary Output, Analog and Analog Output data. Analog values can be handled as word, int32, float or double. Mapping between Modbus TCP addresses and DNP3 points is set up in the DNP-211-S utility software, and the DNP3 side reports the Modbus TCP connection status.
Suited to utility and SCADA installations, the unit uses a metal housing, a 12 to 48 VDC supply and DIN-rail or optional wall mounting. It is rated for operation from -25 to +75 °C.
Applications
- SCADA master station integration with Modbus TCP devices
- Electric and water utility communications
- Connecting RTUs and IEDs to a DNP3 master station
| Product type: | Protocol gateway |
|---|---|
| Interface: | Ethernet, RS-232, RS-485, USB |
| Protocol: | DNP3, Modbus TCP |
| Ports: | 2 x RJ-45, 4 serial, 2 USB |
| Isolation: | RS-485 port 2500 VDC |
| Power input: | +12 ~ +48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail, wall (optional) |
| Housing: | Metal |
Specifications
| Software | |
|---|---|
| OS | Linux Kernel 3.2.14 |
| Protocol | DNP3 slave: • Data Group:1, 10, 11, 30, 40, 41 • Connection: RS-485 / TCP / UDP • Data Points: DI: 8192 DO: 8192 AI: 2048 AO: 2048 Modbus TCP client: • Function:1, 2, 3, 4 , 15, 16 • Connection: Max. 32 Modbus TCP servers |
| Service | SFTP server |
| Main Unit | |
| CPU | Cortex-A8, 1 GHz |
| System Memory | 512 MB DDR3 SDRAM |
| Real Time Clock | Yes (Provide seconds, minutes, hours, day of week, month, year) |
| Watchdog Timer | Yes, Dual Watchdog Timer |
| Display | |
| Signal | VGA (Analog RGB) |
| LED Indicators | |
| Status | 1 x PWR(Power) 1 x RUN(Running) 1 x L1 1 x L2 1 x L3 |
| Ethernet | |
| Ports | 2 x RJ-45, 10/100/1000 Base-TX |
| COM Ports | |
| Ports | 1 x RS-232 (Console, Non-isolated) 1 x RS-232, Non-isolated 1 x RS-485, Non-isolated 1 x RS-485 (2500 VDC, Isolated) |
| USB | |
| Ports | 2 |
| Specification | USB 2.0 (Host) |
| Power | |
| Input Range | +12 VDC ~ +48 VDC |
| Consumption | 4.8 W |
| Mechanical | |
| Casing | Metal |
| Dimensions (mm) | 35 x 167 x 119 (W x L x H) |
| Installation | DIN-Rail or Wall Mounting (optional) |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.