HART
The HRT-227CS CR converts a HART loop into a single mode fiber link, so HART field devices can be monitored over distances that copper cabling cannot practically cover. Its 1310 nm SC duplex optical port reaches up to 30 km, and the unit suits engineers who need to bring remote transmitters onto a central HART host without losing the digital data.The converter handles both HART short and long frames and supports burst mode. It can run in point-to-point or multi-drop configuration with up to 15 HART slave devices, and it allows two HART masters on the network. A selectable 250 Ω loop resistor is set by DIP switch, so the unit can be fitted without an external resistor where one is required.Configuration is carried out with the free HC_Tool utility over an RS-232 configuration port, and firmware can be updated through the same COM port. Fiber break detection and a built-in watchdog help with fault diagnosis, while 4 kV ESD protection and UL1577 isolation on the HART port support reliable installation. The unit mounts on a DIN rail and is rated for an operating temperature of -25 ~ +75 °C.ApplicationsCurrent measuringPetrochemical industryEnvironment monitoringTunnel monitoringMonitor systemsBuilding monitoring
HRT-310 CR is a HART master to Modbus slave gateway. It lets a Modbus master access HART field devices, such as transmitters and actuators, so their data can be brought into an existing Modbus network without custom HART handling. The HG_Tool software is provided for module configuration and HART device diagnosis.The gateway supports HART short and long frames, burst mode and point-to-point or multi-drop topologies, with up to 15 HART devices. Two HART masters can be allowed, and HART devices can be replaced on-line. The Modbus side offers RTU and ASCII formats in slave mode over RS-232 (3-wire), RS-422 or RS-485.Typical use is integrating HART flow meters into an HMI or SCADA system. Each HART device appears to the host as a Modbus slave, so the host can use its built-in Modbus RTU communication to read the devices directly.ApplicationsIndustrial automationFactory automationProcess automationIntegrating HART flow meters and other HART devices into HMI or SCADA systems via ModbusConnecting HART devices to Modbus networks in multi-channel RS-485 installations
HRT-310-UTA CR is a HART master gateway that bridges serial HART field devices and Modbus networks. The Modbus master accesses HART devices through the gateway, so transmitters, actuators and similar instruments appear as Modbus slaves to an HMI, SCADA system or PLC. Configuration and HART device diagnosis are handled with the HG_Tool software utility.The gateway supports point-to-point and multi-drop HART topologies with up to 15 HART devices, using short and long frames and burst mode. Two HART masters can be allowed, and long frame addresses are acquired automatically. Modbus RTU and Modbus ASCII are both supported in Modbus slave mode over RS-232, RS-422 or RS-485.This CR variant is intended for -40 ℃ applications, with an operating range of -40 ~ +75 °C. It is designed for DIN-rail mounting in an upright orientation and runs from an unregulated +10 ~ +30 VDC supply.ApplicationsIndustrial automationFactory automationProcess automationIntegrating HART flow meters and field transmitters into HMI or SCADA systems over Modbus
HRT-370 is a HART signal filter for installations where an analogue current reading and HART communication share the same loop. The HART signal is split into two outputs: one passes the original HART signal through, while the other delivers a filtered, pure analogue current, so both data paths can be processed without interference from the HART carrier.The module works with 2-wired or 4-wired HART devices in point-to-point connections and supports both HART Burst mode and point-to-point HART mode. It allows two HART masters to be connected, and its loop power function supplies +30 V from the module. The analogue output is isolated to 2500 VDC and specified with a 250Ω load resistor and 40 ms response time at 250 Ω.Suits engineers who need both HART data and a stable analogue current from one instrument.Mounts on DIN-rail, with an unregulated +10 ~ +30 VDC supply input and reverse polarity protection.Rated for operation from -25 ~ +75 °C, with storage from -30 ~ +80 °C.ApplicationsMeasuring analogue current from HART transmitters while keeping HART communication active on the same loopPoint-to-point HART instrument loops where analogue data collection must remain precise
The HRT-710 CR bridges HART field devices onto a Modbus network. It acts as the HART master and exposes each connected device as a Modbus slave, so an HMI or SCADA system can read HART data using its standard Modbus RTU or ASCII communication.Up to 15 HART devices can be connected in point-to-point or multi-drop topology, and the unit supports two HART masters. Configuration and HART device diagnosis are handled through the HG_Tool software utility, and firmware can be updated via the COM port. Loop power is not supplied by this model.Suited to flow meters, transmitters and actuators in factory and process automationCertified CE, UKCA, FCC, RoHS and WEEEApplicationsIndustrial automationFactory automationProcess automationIntegrating HART flow meters and transmitters into HMI or SCADA systems over Modbus
The HRT-710-UTA CR is a HART master to Modbus slave gateway. It lets a Modbus master access HART devices such as transmitters and actuators, so their data can be integrated into an HMI or SCADA system without a separate HART interface on the host.The gateway supports point-to-point and multi-drop HART topologies with up to 15 HART devices, using short and long frames and HART burst mode. On the serial side it supports Modbus RTU and Modbus ASCII over RS-232, RS-422 or RS-485. Each module presents its HART devices as Modbus slaves, and configuration and HART device diagnosis are handled with the HG_Tool software utility.The CR ordering code is the variant built for the -40 ℃ application, with an operating range of -40 ~ +75 °C. It mounts on DIN-rail or on a wall in horizontal orientation.Suited to integrating HART flow meters and other HART field devices into Modbus networksApplicationsIndustrial automationFactory automationProcess automation
The HRT-711 CR works as the HART master device in a Modbus network. A Modbus master can access 2-wire or 4-wire HART devices such as transmitters and actuators through its 10/100Base-TX Ethernet port, so field instruments can be brought into a Modbus system without building a separate HART interface.On the HART side, the gateway provides one port with two HART masters, operating in point-to-point or multi-drop mode with up to 15 HART devices. It handles short and long frames and HART burst mode, and the 250 Ω loop resistor is selected by jumper. Only digital HART data is carried.Configuration is carried out with the utility software supplied by the manufacturer. The unit runs from an unregulated +10 ~ +30 VDC supply, operates from -25 ~ +75 °C, and mounts on DIN rail or wall. It is marked CE, UKCA, FCC, RoHS and WEEE.ApplicationsIndustrial automationFactory automationProcess automation
The HRT-711-UTA is a gateway for HART master communication. It lets a Modbus master read from and access HART field devices such as transmitters and actuators, so existing HART instrumentation can be integrated into a Modbus network without redesigning the field wiring.The gateway offers one HART port that supports 2-wired or 4-wired devices in point-to-point or multi-drop topology, with up to 15 HART devices. Two HART masters can be used, and both short and long frame formats are supported along with burst mode. Configuration is carried out with the supplied utility software, and firmware can be updated through the RS-232 COM port.This ordering code is the variant specified for -40 °C applications, with an operating range of -40 to +75 °C. It is suited to industrial, factory and process automation installations where HART devices must be connected to Modbus TCP/UDP systems.ApplicationsIndustrial automationFactory automationProcess automation
I-7547 CR bridges Ethernet and four HART channels, letting engineers reach HART field devices from a PC or control application over the network. Used with the VxComm utility, the HART network appears as virtual COM ports, so existing serial software can collect and process HART data without rework. The grey-cover CR variant is the RoHS-compliant ordering option of the I-7547.The converter supports HART short and long frames, burst mode, and point-to-point or multi-drop topologies with up to 15 HART slave devices. Two HART masters can be allowed at the same time, and each HART port has a selectable 250 Ω terminal resistor. The free HC_Tool utility handles module configuration and HART communication tests, while firmware can be updated over Ethernet.The unit can also act as a HART slave when paired with the HDS (HART Device Simulator) software, which simulates several HART field devices so master programs can be developed and verified without physical instruments. Typical uses include current measurement, environmental and building monitoring, tunnel monitoring, and petrochemical plant applications, including FDT-based configuration systems.ApplicationsCurrent measuringPetrochemical industryEnvironment monitoringTunnel monitoringBuilding monitoringMonitor systemsFDT (Field Device Tool) based HART configuration and control
The I-7567 CR links a Windows PC to HART field devices over USB. It can act as a HART master, so the PC reaches slave devices through a virtual COM port, or as a HART slave when paired with the HDS simulation software. Engineers can therefore build and test HART data collection without first installing field instruments.The converter supports HART short and long frames as well as Burst mode. It handles point-to-point or multi-drop wiring with up to 15 HART slave devices and allows two HART masters. A bundled utility handles module configuration and HART communication tests, and firmware can be updated over USB.Power comes entirely from the USB port, so no separate supply is needed. The unit provides 3000 VDC isolation and 4 kV ESD protection, and the 250 Ω terminal resistor can be switched in as required. Support for the FDT standard enables online HART configuration systems.ApplicationsCurrent measurementPetrochemical industryEnvironment monitoringTunnel monitoringBuilding monitoringMonitoring systemsFDT-based HART configuration and control systems
The I-7570 CR bridges a serial host and HART field devices. Connect a PC or controller over RS-232, RS-422 or RS-485 and access HART transmitters, actuators and current output devices without writing HART framing yourself. Used with the HC_Tool utility, it operates as a HART master; with the HDS utility, it can emulate HART slave devices.Point-to-point or multi-drop HART operation is supported, with up to 15 HART slave devices. Two HART masters are allowed, and both HART short and long frames and Burst mode are supported. The bundled utility tool helps you configure the module and test HART communication quickly.The gray-cover version is powered from an unregulated +10 ~ +30 VDC supply and includes 4 kV ESD protection and a built-in watchdog. It mounts on DIN-rail or wall and is suited to monitoring and instrumentation installations, including FDT-based configuration systems.ApplicationsCurrent measuringPetrochemical industryEnvironment monitoringTunnel monitoringBuilding monitoringMonitor systemsFDT (Field Device Tool) based HART configuration and control
8-channel HART Current Input Module (Gray Cover).
The I-9720 CR bridges HART field devices and Modbus masters. It presents two HART channels to a Modbus RTU or ASCII master, so engineers can read HART device data without writing a dedicated HART driver. It is intended for use with Windows, WinCE and Linux 9K series PACs.Wiring is simplified by the built-in HART loop power of +27 VDC and a 250 Ω, 2 W loop resistor, selectable via DIP switch. Both point-to-point and multi-drop HART topologies are supported, with up to 15 HART devices, and both short and long frame types are handled.Configuration is carried out over USB Type C using the free HG_Tool, which is also used to monitor HART device data. LED indicators (PWR, RUN, E0, E1) and an RST button support commissioning and recovery.ApplicationsRetrieving HART device data in Modbus master systems built on 9K series PACsIntegrating HART field instruments into Modbus RTU or ASCII networks