ET-7000
The ET-7002 combines analog input, digital input and relay output channels in a single DIN-rail Ethernet module. Its three differential analog inputs can each be set to voltage or current input, with ranges from ±150 mV up to ±10 V and 0 ~ 20 mA, ±20 mA or 4 ~ 20 mA, selected by jumper. Each input has 240 Vrms overvoltage protection and open wire detection for 4 ~ 20 mA signals.The six wet-contact digital inputs support sink and source wiring and can operate as 32-bit counters at up to 100 Hz. The three Form A power relays are rated 5 A at 250 VAC or 24 VDC (resistive load), with programmable power-on and safe values.Communication runs over a single 10/100 Base-TX RJ-45 port using Modbus TCP or Modbus UDP. A built-in web server and web HMI, ID, password and IP filter access control, and dual watchdogs support straightforward commissioning and supervised operation. The ET-7002 is rated for -25 ~ +75 °C operation.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7005 CR is an Ethernet remote I/O module for temperature monitoring with thermistors. Each of its eight differential inputs can be set up with its own thermistor type, and a range of Precon, Fenwell and YSI sensors is supported. Where none of these fit, a user-defined type can be added by entering Steinhart coefficients.Four isolated open-collector digital outputs (sink type) provide alarm signalling, each protected against short-circuit and overload. Communication runs over a single 10/100 Base-TX RJ-45 port using Modbus TCP or Modbus UDP, with ID, password and IP filter access control. A built-in web server and web HMI, together with a dual watchdog, support day-to-day supervision and configuration.Isolation is rated at 2500 VDC for I/O and 1500 VDC for Ethernet, and the thermistor inputs offer overvoltage protection up to 110 VDC/VAC. These characteristics suit building, factory and machine automation, as well as remote maintenance, remote diagnosis and testing equipment.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7015 is built for measuring temperature over long cable runs. Each of its 7 channels accepts Pt100, Pt1000, Ni120, Cu100 or Cu1000 sensors, and three-wire RTDs are compensated automatically whatever the wire length, so the lead resistance does not have to be tuned out by hand.Open-wire detection on every channel helps identify broken sensor leads quickly. Communication runs over Modbus TCP and Modbus UDP, with a built-in web server and web HMI for configuration and monitoring. Access is controlled by ID, password and IP filter, and dual watchdogs support fault recovery.Isolation is rated at 2500 VDC for I/O and 1500 VDC for Ethernet. The module is RoHS-compliant, offers 4 kV ESD protection, and runs from +10 ~ +30 VDC on a DIN-rail mount across an operating range of -25 ~ +75 °C. Typical uses include building automation, factory and machine automation, remote maintenance and diagnosis, and test equipment.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7016 is an Ethernet I/O module for remote strain gauge measurement. It provides two differential analogue input channels that accept full-bridge, half-bridge and quarter-bridge wiring, along with a 0 ~ 10 V excitation output to power the bridge. Each analogue input can be configured with its own range, covering millivolt, voltage and current spans, so a single module can handle mixed sensor types.On the digital side, the module offers two wet-contact inputs that can also count pulses, and two isolated open-collector outputs rated at 700 mA per channel. The digital outputs can be set as alarm outputs. Long-distance measurements are supported with compensation for the voltage loss along the cable run.Communication is handled through a single 10/100 Base-TX RJ-45 port using Modbus TCP or Modbus UDP. A built-in web server and web HMI allow configuration and monitoring, and access can be restricted by ID, password and IP filter. Dual watchdogs and I/O pair connection add to the module's operational reliability, and it mounts on a DIN rail.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7017 CR is an Ethernet I/O module that brings eight differential analogue inputs and four digital outputs onto a Modbus network. Each analogue channel can be set to voltage or current and given its own input range, which suits mixed sensor setups without changing hardware. This ordering code is listed with RoHS compliance.The digital outputs are isolated open-collector sink types rated at 700 mA per channel, with short-circuit and overload protection. Power-on and safe values are programmable, so outputs can be defined for start-up and fault conditions. Sampling can be switched between normal mode at 10 Hz and fast mode at 50 Hz across all channels.Host communication uses Modbus TCP or Modbus UDP over a single 10/100 Base-TX RJ-45 port. A built-in web server and web HMI are provided, Ethernet access is controlled by ID, password and IP filter, and dual watchdog functions are included.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7017-10 is an Ethernet-connected analog input module for engineers who need to bring a mix of voltage and current signals onto a network without a separate data acquisition unit. Each analog channel can be configured with its own input range, and the jumper settings determine whether a channel accepts voltage or current, so one module can serve several sensor types on the same panel.Sampling can be run in normal mode at 10 Hz across all channels or in fast mode at 50 Hz across all channels, allowing the speed to be matched to the application. The module provides a 16-bit resolution, with an accuracy of ±0.1% in normal mode and ±0.5% or better in fast mode. Overvoltage protection is rated at 240 Vrms for differential inputs and 150 Vrms for single-ended inputs.Communication is handled through one 10/100 Base-TX RJ-45 port supporting Modbus TCP and Modbus UDP, with ID, password and IP filter access control. A built-in web server and web HMI, along with dual watchdogs, support commissioning and supervision. The module is powered from a +10 ~ +30 VDC terminal block and mounts on a DIN-rail.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7024 combines four analogue outputs, five digital inputs and five digital outputs in one DIN-rail Ethernet module. A single unit can drive field actuators and read switch or sensor states over Modbus TCP or Modbus UDP, which keeps wiring and panel space to a minimum.Each analogue output can be set to voltage (+0 ~ +5 VDC, ±5 VDC, +0 ~ +10 VDC, ±10 VDC) or current (0 ~ 20 mA, 4 ~ 20 mA), with the choice made per channel by jumper. The digital inputs accept dry or wet contacts and include a 32-bit counter function, while the digital outputs are isolated open-collector sink type rated at 600 mA per channel.Built-in web server and web HMI, dual watchdog and I/O pair connection simplify commissioning and monitoring. The module provides 2500 VDC I/O isolation, ±4 kV ESD contact protection on each terminal, and is RoHS compliant.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7026 CR is a multi-function Ethernet I/O module that brings analog and digital signals onto a single network node. Its six differential analogue inputs and two analogue outputs cover a wide range of process signals, while two digital inputs (with counter capability) and two open-collector digital outputs handle discrete control tasks, all from one DIN-rail unit.Each analogue input can be configured for its own range, covering voltage and current options from ±500 mV up to ±10 V and 4 ~ 20 mA, with 240 Vrms overvoltage protection. Input and output types are selected by jumper position, so the same module suits a range of field devices. Each channel can be set up individually.The module suits engineers who need Modbus TCP or Modbus UDP access without a separate controller at the I/O point. A built-in web server and web HMI support setup and monitoring, while the dual watchdog, programmable power-on and safe values, and I/O pair connection help maintain predictable behaviour during faults.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7028 CR is an Ethernet I/O module that provides eight analogue output channels for controlling field devices from a network. It suits engineers who need networked analogue control in building, factory and machine automation.Each channel can be set to a voltage range (+0 ~ +5 VDC, ±5 VDC, +0 ~ +10 VDC or ±10 VDC) or a current range (0 ~ 20 mA or 4 ~ 20 mA). The output type is chosen per channel by jumper position, and channels can be configured individually. Output resolution is 12-bit with an accuracy of ±0.1% of FSR, and open wire detection is available for 4 ~ 20 mA use. Power-on and safe values are programmable.Communication uses one RJ-45 10/100 Base-TX port with Modbus TCP and Modbus UDP. A built-in web server and web HMI, ID, password and IP filter access control, and programmable module and communication watchdogs support secure and supervised operation. The module is powered from +10 ~ +30 VDC with reverse polarity protection and is designed for DIN-rail mounting over -25 ~ +75 °C.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7042 CR is an Ethernet I/O module that switches 16 sink-type digital outputs over a single 10/100 Base-TX RJ-45 port. Each output is an isolated open collector rated from +5 to +30 VDC, with up to 100 mA per channel at 25°C. Power-on and safe values for the outputs are programmable, so the module can drive known states when the network or host is unavailable.Communication uses Modbus TCP or Modbus UDP, and the built-in web server provides a Web HMI for setup and monitoring without additional software. Access control is handled through ID, password and IP filtering. A module watchdog and a communication watchdog, both programmable, help maintain safe operation, and the I/O pair connection feature is available.Isolation is rated at 1500 VDC on the Ethernet side and 2500 VDC on the I/O side. There is no channel-to-channel isolation. The module can drive the RM series relay modules directly to switch inductive loads. It is powered from +10 to +30 VDC through a terminal block with reverse polarity protection, draws 2.7 W maximum, and mounts on DIN rail.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
ET-7042-UT CR is a DIN-rail Ethernet I/O module that switches 16 isolated open-collector digital outputs in sink configuration. Each channel handles a load voltage of +5 ~ +30 VDC and up to 100 mA at 25°C, so it can drive loads directly or feed an RM series relay module when switching inductive loads.The module is aimed at engineers who need remote, networked output control without a local PLC. It supports Modbus TCP and Modbus UDP, and includes a built-in web server with web HMI for configuration and monitoring. Access is restricted by ID, password and IP filter, and a dual watchdog helps the output stage return to a defined state after faults.Power-on and safe values for the digital outputs are programmable, which allows each installation to define the state of its outputs at start-up and during communication loss. The listed operating range of -40 ~ +75°C suits cabinets in demanding environments, with 2500 VDC I/O isolation and 1500 VDC Ethernet isolation.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
ET-7044 CR is a DIN-rail Ethernet I/O module that pairs eight wet-contact digital inputs with eight sink-type digital outputs. Each input can be used as a 32-bit counter, which suits pulse counting and event tracking on machines, building services and test equipment. Each output channel can switch a 300 mA load at 25 °C, so it can drive a power relay module directly.The module communicates over Modbus TCP and Modbus UDP through a 10/100 Base-TX RJ-45 port. A built-in web server with Web HMI allows configuration and monitoring from a browser, and access is controlled by ID, password and IP filter. Dual programmable watchdogs cover the module and the communication link, and the digital outputs have programmable power-on and safe values for defined behaviour during start-up or fault conditions.Electrical isolation is rated at 1500 VDC for the Ethernet side and 2500 VDC for the I/O side. The digital inputs and outputs are not isolated from each other channel to channel. The module is powered from a +10 ~ +30 VDC terminal block with reverse polarity protection, and it operates from -25 ~ +75 °C.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
ET-7050 CR is an Ethernet I/O module from the ET-7000 series that combines 12 digital input channels with 6 digital output channels in a single DIN-rail unit. Each digital input can be used as a 32-bit counter, so the module suits pulse counting and status monitoring tasks alongside on/off control.The module supports Modbus TCP and Modbus UDP over a single 10/100 Base-TX RJ-45 port, allowing it to be integrated with HMI, SCADA, PLC and other industrial control software. A built-in web server and web HMI provide browser-based monitoring and control, and a dual watchdog with programmable module and communication timers supports fault handling.Its digital outputs are isolated open-collector sink types, and the module offers 2-way isolation rated at 1500 VDC for Ethernet and 2500 VDC for I/O. Certifications listed for the product include CE, UKCA, FCC, RoHS and WEEE.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7051 CR is an Ethernet remote I/O module that brings 16 wet contact digital inputs onto a Modbus network. Each channel can also be set up as a 32-bit counter, which makes the module suited to counting pulses from sensors, meters and switch contacts without a separate counting device.Isolation is provided between the Ethernet side, the I/O side and the power input, with 2500 VDC rated for I/O and 1500 VDC for Ethernet. Channels are not isolated from one another. The module is designed for installations where hazardous voltages may be present on the input side.The built-in web server and web HMI allow the module to be configured and monitored from a browser. Access is controlled through ID and password protection plus an IP filter, and the module offers a dual watchdog and I/O pair connection for supervised operation.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7052 CR is an Ethernet remote I/O module that combines eight wet-contact digital inputs, each usable as a 32-bit counter, with eight source-type digital outputs. Each output channel can drive a load of up to 650 mA, and the power-on and safe values of the outputs are programmable, so the module can be configured to hold a defined state if communication is lost.Its built-in web server and web HMI allow configuration and monitoring from a browser, while Modbus TCP and Modbus UDP provide straightforward integration with supervisory systems and controllers. Optical isolation rated at 2500 VDC on the I/O and 1500 VDC on the Ethernet side supports use where hazardous voltages are present, although channel-to-channel isolation is not provided.Suitable for building, factory and machine automation, remote maintenance and diagnosis, and test equipment, the ET-7052 CR mounts on a DIN rail and operates from a +10 ~ +30 VDC terminal block supply across a -25 ~ +75 °C operating range.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7053 is an Ethernet remote I/O module that brings 16 dry contact digital inputs onto a Modbus network. Every channel can be used as a 32-bit counter, which suits pulse counting and event monitoring where input states must be reported to a host over Ethernet.Electrical isolation is provided on the input side, with 1500 VDC on the Ethernet interface and 2500 VDC on the I/O. The inputs are not isolated from one another, so channels share a common reference. The module is suitable for installations where hazardous voltages may be present, and its EFT and ESD immunity ratings are stated for use in industrial environments.The built-in web server and Web HMI, dual watchdog, I/O pair connection and access control with ID, password and IP filtering make the ET-7053 straightforward to supervise and secure on a plant network. It mounts on a DIN rail and operates from a +10 ~ +30 VDC supply over a wide temperature range.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7060 CR combines six wet contact digital inputs with six form A power relays in a single Ethernet-connected DIN-rail module. Each input can also operate as a 32-bit counter, which suits pulse counting and status monitoring in automation and remote supervision tasks. Relay power-on and safe values are programmable, so outputs can be set to a defined state when the module starts or communication is lost.Communication is handled over a 10/100 Base-TX RJ-45 port using Modbus TCP or Modbus UDP. A built-in web server and web HMI allow configuration and monitoring through a browser, while dual watchdogs (module and communication, both programmable) help maintain system reliability. Access can be restricted with ID, password and IP filter controls.Isolation is rated at 3000 VDC for the I/O and 1500 VDC for Ethernet, with no channel-to-channel isolation. When switching inductive loads, fit a flyback diode for DC loads or a metal oxide varistor for AC loads to protect the relay contacts and extend relay life.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
The ET-7065 pairs six wet contact digital inputs with six form A PhotoMOS relay outputs in one DIN-rail Ethernet module. Each input can also be configured as a 32-bit counter, so the unit can count events on the same device that switches your loads.Relay power-on and safe values are both programmable, letting you define the output state at start-up and in a safe condition. Optical isolation rated at 3000 Vrms transient overvoltage protection is provided, although channels are not isolated from each other. The module is stated to be suitable for applications where hazardous voltages are present.Relay contact rating of 60 V / 1.0 A at -25 ~ +40 °C, derated to 0.8 A at +40 ~ +60 °C and 0.7 A at +60 ~ +75 °CApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
ET-7066 CR is an Ethernet remote I/O module that switches loads through eight form A PhotoMOS relay outputs. Each output has a programmable power-on value and safe value, so the outputs can be set to a defined state at power-up and in the safe state.The module suits engineers who need to switch hazardous-voltage circuits from a networked controller. Its optical isolation is rated at 3000 VDC for the I/O and 1500 VDC for Ethernet. The relay channels are not isolated from each other. Modbus TCP and Modbus UDP are both supported, and the built-in web server and web HMI allow configuration and status checks.Watchdog functions cover both the module and the communication link, and the watchdog is programmable. The module is powered from a +10 ~ +30 VDC terminal block with reverse polarity protection, and it mounts on DIN-rail. The operating range is -25 ~ +75 °C.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
ET-7067 CR is a DIN-rail Ethernet I/O module that gives engineers eight form A (SPST N.O.) power relay outputs, each rated 5 A at 250 VAC or 24 VDC for resistive loads. It is aimed at switching jobs in building, factory and machine automation where the controller talks to the module over Modbus TCP or Modbus UDP.Each relay has its own programmable power-on value and safe value, so the outputs can be set to a defined state at start-up and during communication faults. The I/O side is optically isolated to 3000 VDC for transient overvoltage protection, and the module can be used where hazardous voltages are present. Note that there is no channel-to-channel isolation between the relays.The module is powered from a +10 ~ +30 VDC terminal block with reverse polarity protection, and it has a built-in web server with web HMI, ID, password and IP filter access control, and dual watchdogs for the module and communication. It is intended for operation from -25 ~ +75 °C.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The ET-7083 CR is a three-axis encoder and counter module for Ethernet networks. Each axis can be set individually to Quadrant, CW/CCW or Pulse/Direction counting, so one unit can serve several motion or position feedback inputs without additional counter hardware. Quadrant counting tops out at 1 MHz, while CW/CCW and Pulse/Direction modes reach 4 MHz.Counter values can be kept through a power loss thanks to FRAM-based retention, which can be enabled or disabled as required. The module supports Modbus TCP and Modbus UDP, and includes a built-in web server with web HMI for configuration and monitoring, along with ID, password and IP filter access control.Power is supplied from a terminal block at +10 ~ +30 VDC with reverse polarity protection. The module measures 72 x 123 x 35 mm, mounts on a DIN rail, and operates from -25 ~ +75 °C. It carries CE, UKCA, FCC, RoHS and WEEE marks.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
Ethernet I/O Module with 2-port Ethernet Switch, 4/8-ch Counter/Frequency/Encoder Input, 4-ch DO.
The PET-7002 CR combines three analog inputs, six digital inputs with counter capability and three Form A power relay outputs in a single Ethernet module that can be powered over PoE or from a +12 ~ +48 VDC terminal block. Each analog input is set by jumper to voltage or current, with ranges from ±150 mV to ±10 V, 0 ~ 20 mA, ±20 mA and 4 ~ 20 mA, and is protected against 240 Vrms overvoltage.Engineers will find the module convenient for remote I/O because it provides Modbus TCP and Modbus UDP, a built-in web server with web HMI, and communication security with access control by ID, password and IP filter. A dual watchdog and I/O pair connection support resilient operation, and the relay outputs have programmable power-on and safe values.The module offers 2500 VDC intra-module isolation and 4 kV ESD protection, and it is rated for an operating range of -25 ~ +75 °C. It is intended for DIN-rail installation and is listed as RoHS compliant.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The PET-7005 CR is a PoE Ethernet I/O module for temperature measurement with thermistors. Each of its eight differential inputs can be configured individually, so different thermistor types can be used on different channels. Supported types include Precon ST-A3, Fenwell U and several YSI series, and user-defined thermistors can be added by entering Steinhart coefficients.Four isolated open-collector outputs with short-circuit and overload protection allow the module to drive alarm outputs. Its 2500 VDC intra-module isolation and 110 VDC/VAC overvoltage protection on the thermistor inputs are intended to support reliable operation in electrically demanding installations.Communication is over Modbus TCP and Modbus UDP through a single 10/100 Base-TX RJ-45 port, with ID, password and IP filter access control. The module can be powered from PoE (IEEE 802.3af, Class 1) or from a +12 ~ +48 VDC terminal block, and it mounts on a DIN rail.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment