Liigu põhisisu juurde Liigu otsingu juurde Liigu peamise navigeerimise juurde

PM-3033-CPS CANopen 3-Phase Power Meter, 1A/5A CT Input

Toote teave "PM-3033-CPS CANopen 3-Phase Power Meter, 1A/5A CT Input"

PM-3033-CPS CR is a CANopen three-phase power meter for engineers who need real-time energy readings from low-voltage primary circuits or medium/high-voltage secondary circuits. It accepts secondary-side 1A/5A current transformers directly, so dedicated metering CTs are not required, which keeps installation costs down.

The meter reports true RMS voltage and current, active, reactive and apparent power and energy, power factor, frequency and total harmonic distortion. Energy analysis covers 3P4W, 3P3W, 1P3W and 1P2W wiring, and the data update rate is one second. The 10 ~ 500 VAC input range and 50/60 Hz frequency support is suited to a wide range of installations.

The CANopen interface is set up with DIP switches, with baud rates from 125 k (default) to 1 M. The DIN-rail mounted plastic housing, 3000 VDC isolation and +12 ~ 48 VDC power input make it straightforward to fit into generator monitoring and switchgear distribution panels.

Applications

  • Generator monitoring
  • Switchgear distribution systems
  • Energy management
Product type: Power meter
Interface: CANopen
Protocol: CANopen
Isolation: 3000 VDC
Power input: +12 ~ 48 VDC
Operating temperature: -20 ~ +70 °C
Mounting: DIN-rail
Housing: Plastic

Specifications

AC Power Measurement
Wiring3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops3-phase: 1
1-phase:
3 @ 1P2W-1CT
1 @ 1P3W-2CT
Input Voltage10 ~ 500 V
Input Current0.05 A ~ 5 A
Input Frequency50/60 Hz
W AccuracyBetter than 0.5% (PF=1; Input Current >0.5A)
Power Parameter MeasurementTrue RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate1 Second
CANopen
Baud Rate125 k (default), 250 k, 500 k, 1 M; DIP Switch Selectable
Isolation3000 VDC
ProtocolCANopen
Power
Input Range+12 ~ 48 VDC
Consumption2W
Mechanical
CasingPlastic
Dimensions (mm)33 x 127 x 100 (W x L x H)
InstallationDIN-Rail Mounting
Environment
Operating Temperature-20 ~ +70 °C
Storage Temperature-25 ~ +80 °C
Humidity10 ~ 90% RH, Non-condensing

Specifications as published by the manufacturer. Subject to change.