M-2217CI-4 RS-485 Analog Input Module, 4-ch Differential, Channel Isolation
4-channel differential voltage and current input module with 3000 VDC channel-to-channel isolation, Modbus RTU and DCON over RS-485. Ordering code M-2217CI-4 CR.
- 4 differential analog input channels with software-selectable voltage or current input
- Individual channel configuration across ±1 V to ±10 V and 0–20 mA, 4–20 mA, ±20 mA ranges
- Open-wire detection on 4–20 mA channels
- Adjustable sampling rate: 200 Hz fast mode or 10 Hz normal mode
- Time-stamped voltage and current records, 480,000 per channel
- 3000 VDC channel-to-channel isolation with 120 VDC overvoltage protection
436,00 € per piece
| 1–9 pcs | 436,00 € | |
|---|---|---|
| 10–30 pcs | 423,00 € | −3 % |
| 31+ pcs | 414,00 € | −5 % |
Информация за продукта "M-2217CI-4 RS-485 Analog Input Module, 4-ch Differential, Channel Isolation"
M-2217CI-4 is a 4-channel differential analog input module for RS-485 networks, suited to engineers who need electrically isolated measurement channels. Each channel can be set in software for voltage or current input and configured individually for its range, from ±1 V up to ±10 V, or 0–20 mA, 4–20 mA and ±20 mA. Open-wire detection is provided on the 4–20 mA channels.
The module offers a selectable sampling rate of 200 Hz in fast mode or 10 Hz in normal mode, with time-stamped recording of both voltage and current values. With 16-bit resolution and an accuracy of 0.1% of FSR, it is a practical choice for multi-point process signal acquisition where data traceability matters.
For harsh installations, the module includes 120 VDC overvoltage protection, 50 mA overcurrent protection at 110 VDC (max.), EMS protection against EFT, ESD and surge, and 3000 VDC channel-to-channel isolation. Mounting is on DIN rail, with wall mounting available using the optional ASO-0015 kit.
Applications
- Multi-channel analog sensor and transmitter monitoring in industrial plants
- Process signal acquisition where channels must be isolated from each other
- Data logging of voltage and current signals with time stamps
- Remote I/O for RS-485 networks in electrically noisy environments
| Product type: | Analog Input Module |
|---|---|
| Interface: | RS-485 |
| Protocol: | DCON, Modbus RTU |
| Analog inputs: | 4 |
| Ports: | 1 |
| Isolation: | 3000 VDC channel-to-channel |
| Power input: | +10 ~ +48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| CPU Module | |
|---|---|
| CPU | 32-bit ARM |
| Watchdog Timer | Module, Communication (Programmable) |
| Isolation | |
| Intra-module Isolation | 3750 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal ±8 kV Air for Random Point |
| Surge (IEC 61000-4-5) | ±2 kV for Power Line |
| LED Indicators | |
| Status | 1 x Power and Communication |
| Analog Input | |
| Channels | M-2217CI-4: 4 Differential M-2217CI: 8 Differential |
| Type | Voltage, Current (Software Configurable) |
| Range | Voltage: ±1 V, ±2.5 V, ±5 V, ±10 V Current: 0 ~20 mA, 4 ~ 20 mA, ±20 mA |
| Resolution | 16-bit |
| Accuracy | 0.1% of FSR |
| Sampling Rate | Normal Mode: 10 Hz (Total) Fast Mode: 200 Hz (Total) |
| Input Impedance | Voltage: 20 MΩ Current: 135 Ω |
| Overvoltage Protection | 120 VDC |
| Overcurrent Protection | 50 mA at 110 VDC (max.) |
| Individual Channel Configuration | Yes |
| Channel-to-Channel Isolation | 3000 VDC |
| Open Wire Detection | For 4 ~ 20 mA only |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Data Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) |
| Protocol | Modbus RTU, DCON |
| Bias Resistor | 10 kΩ |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +48 VDC |
| Consumption | M-2217CI-4: 2.8 W max. M-2217CI: 4.8 W max. |
| Mechanical | |
| Dimensions (mm) | 33 x 184 x 129 (W x L x H) |
| Installation | DIN-Rail mounting<br/>Wall mounting (Optional ASO-0015) |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.