iXN-0VC iWSN CO2e/TVOC Sensing Module, 27 cm Cable
CO2e and TVOC sensing module that extends the iWSN environmental sensing module, drawing its power from the host with no external supply. Wall-mount or magnet installation with a 27 cm cable.
- Measures CO2e from 400 ppm to 60000 ppm and TVOC from 0 ppb to 60000 ppb
- Resolution varies by range, from 1 ppm and 1 ppb at the low end to 31 ppm and 32 ppb at the top of the scale
- Powered by the iWSN environmental sensing module via the audio line, with no external power supply needed
- Consumption of 0.16 W
- Wall-mount or magnet adsorption installation
- 27 cm cable length
133,00 € per piece
| 1–9 pcs | 133,00 € | |
|---|---|---|
| 10–30 pcs | 129,00 € | −3 % |
| 31+ pcs | 126,00 € | −5 % |
Informacije o izdelku "iXN-0VC iWSN CO2e/TVOC Sensing Module, 27 cm Cable"
iXN-0VC CR is a CO2e and TVOC sensing module designed to connect to the iWSN environmental sensing module, adding CO2e and TVOC measurement to an existing iWSN installation.
The module is energised by the iWSN environmental sensing module through the audio line, so no separate power supply is required. It measures CO2e from 400 ppm to 60000 ppm and TVOC from 0 ppb to 60000 ppb, with resolution that steps up across each range. Its compact 25 x 30 x 20.2 mm housing and 27 cm cable suit installation where the sensor needs to sit away from the host unit.
For setup and maintenance, the module can be fitted by wall mounting or by magnet adsorption. It is rated for operation from 0 °C to +45 °C and 10 to 95% RH, non-condensing, and is supplied as an RoHS version with CE and WEEE certification noted.
Applications
- Factory environmental monitoring system
| Product type: | iWSN environmental sensing module |
|---|---|
| Power input: | Via iWSN module (audio line) |
| Operating temperature: | 0 ~ +45 °C |
| Mounting: | Wall-mount, magnet |
Specifications
| CO2e Measurement | |
|---|---|
| Rnge | 400 ppm to 60000 ppm |
| Resolution | 1 ppm (400 ppm~ 1479 ppm) 3 ppm (1479 ppm~ 5144 ppm) 9 ppm (5144 ppm~ 17597 ppm) 31 ppm (17597 ppm~ 60000 ppm) |
| TVOC Measurement | |
| Range | 0 ppb to 60000 ppb |
| Resolution | 1 ppb (0 ppb~ 2008 ppb) 6 ppb (2008 ppb~ 11110 ppb) 32 ppb (11110 ppb~ 60000 ppb) |
| Power | |
| Consumption | 0.16W |
| Input Type | iWSN environmental sensing module provides power through the audio line. |
| Mechanical | |
| Dimensions (mm) | 25 x 30 x 20.2 (W x L x H) |
| Installation | Wall-mount or magnet adsorption |
| Cable Length | 27 cm |
| Environment | |
| Operating Temperature | 0 °C ~ +45 °C |
| Storage Temperature | -30 ~ +80°C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.