tM-AD2 2-Channel Isolated Analog Input Module, Voltage/Current Input
The tM-AD2 CR is a 2-channel isolated analog input module for RS-485 networks, accepting voltage and current signals with a programmable range and 120 VDC overvoltage protection.
- Two single-ended analog inputs with voltage and current ranges, including 0 ~ 20 mA and 4 ~ 20 mA
- Programmable input range per channel, with individual channel configuration
- Adjustable sampling: Normal Mode 14-bit at 10 Hz (±0.1%), Fast Mode 12-bit at 200 Hz (±0.5%)
- 2500 VDC intra-module isolation and 120 VDC overvoltage protection
- 4 kV ESD protection on each terminal (contact) and 4 kV EFT protection on power
- RS-485 port with DCON, Modbus RTU and Modbus ASCII, 1200 ~ 115200 bps
123,00 € per piece
| 1–9 pcs | 123,00 € | |
|---|---|---|
| 10–30 pcs | 119,00 € | −3 % |
| 31+ pcs | 117,00 € | −5 % |
Informações de produto "tM-AD2 2-Channel Isolated Analog Input Module, Voltage/Current Input"
tM-AD2 CR is a DIN-rail analog input module for RS-485 remote I/O networks. It has two single-ended inputs that accept voltage and current signals, and each input can be set to one of seven ranges, from 0 ~ 500 mV up to 4 ~ 20 mA. Individual channel configuration and open wire detection help with commissioning and fault finding.
Engineers choose the tM-AD2 CR when signals need to be read reliably in electrically noisy or exposed environments. It offers 2500 VDC intra-module isolation, 120 VDC overvoltage protection, 4 kV ESD protection and reverse polarity protection on the power input. The module runs from 10 ~ 30 VDC and draws 0.7 W max.
The sampling rate is adjustable. Normal mode gives 14-bit resolution and ±0.1% accuracy at 10 Hz, while fast mode gives 12-bit resolution and ±0.5% accuracy at 200 Hz. The module communicates over one RS-485 port using DCON, Modbus RTU or Modbus ASCII, and a dual watchdog covers the module and communication.
Applications
- Industrial automation
- Industrial machinery
- Building automation
- Food and beverage systems
- Semiconductor fabrication
- Control systems
| Product type: | Analog Input Module |
|---|---|
| Interface: | RS-485 |
| Protocol: | DCON, Modbus ASCII, Modbus RTU |
| Analog inputs: | 2 |
| Ports: | 1 |
| Isolation: | 2500 VDC |
| Power input: | 10 ~ 30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Module, Communication (Programmable) |
| Isolation | |
| Intra-module Isolation | 2500 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power |
| ESD (IEC 61000-4-2) | ±4 kV Contact for Each Terminal ±8 kV Air for Random Point |
| LED Indicators | |
| Status | 1 x Power and Communication |
| Analog Input | |
| Channels | 2 Single-ended |
| Type | Voltage, Current |
| Range | 0 ~ 500 mV, 0 ~ 1 V, 0 ~ 2.5 V, 0 ~ 5 V, 0 ~ 10 V, 0 ~ 20 mA, 4 ~ 20 mA |
| Resolution | Normal Mode: 14-bit Fast Mode: 12-bit |
| Accuracy | Normal Mode: ±0.1% Fast Mode: ±0.5% |
| Sampling Rate | Normal Mode: 10 Hz Fast Mode: 200 Hz |
| Input Impedance | Voltage: 10 MΩ Current: 125 Ω |
| Overvoltage Protection | 120 VDC |
| Overcurrent Protection | 50 mA at 110 VDC |
| Individual Channel Configuration | Yes |
| Open Wire Detection | Yes |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Data Format | (N, 8, 1), (N, 8, 2), (O, 8, 1), (E, 8, 1) |
| Protocol | DCON, Modbus RTU, Modbus ASCII |
| Power | |
| Reverse Polarity Protection | Yes |
| Consumption | 0.7 W max. |
| Powered from Terminal Block | 10 ~ 30 VDC |
| Mechanical | |
| Dimensions (mm) | 52 x 98 x 27 (W x L x H) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +75 °C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.