tET-PD2R1 Tiny Ethernet I/O Module, 2-ch DI (Dry) and 1-ch Power Relay
Compact Ethernet I/O module with two dry-contact digital inputs and one 5.0 A power relay output, controlled over Modbus TCP/UDP or MQTT.
- Two dry-contact digital inputs with latched mode, 32-bit counters and frequency measurement
- One Form A (SPST N.O.) power relay output rated 5.0 A per channel at 25 °C
- Modbus TCP, Modbus UDP and MQTT protocol support over a 10/100 Base-Tx RJ-45 port
- Built-in web server for configuration, with password and IP filter access control
- Dual watchdog (CPU and host) with programmable DO power-on and safe values
- I/O pair connection (push and pull) for DI to remote DO control over Ethernet
102,00 € per piece
| 1–9 pcs | 102,00 € | |
|---|---|---|
| 10–30 pcs | 99,00 € | −3 % |
| 31+ pcs | 97,00 € | −5 % |
Informações de produto "tET-PD2R1 Tiny Ethernet I/O Module, 2-ch DI (Dry) and 1-ch Power Relay"
The tET-PD2R1 CR is a compact IP-based Ethernet I/O module that pairs two dry-contact digital inputs with a single Form A power relay output. It suits engineers who need to monitor switch contacts and switch a load from a network host, within a very small footprint that mounts on a DIN rail.
Configuration is handled through a built-in web server, and the module supports Modbus TCP, Modbus UDP and MQTT. Digital inputs can be set to latched mode, and each input offers a 32-bit counter and frequency measurement, with a maximum counting frequency of 3.5 kHz without filter. The module can also be configured for I/O pair connection, polling local DI channels and writing to a remote DO device over Ethernet.
Reliability features include a CPU watchdog and a host watchdog, with a programmable safe value for the relay output if the host controller fails. Output power-on and safe values are configurable, and firmware can be updated over Ethernet. Power is taken from a terminal block at +12 to +48 VDC, with reverse polarity protection.
Applications
- Factory automation
- Building automation
- Home automation
- Remote maintenance
| Product type: | Ethernet I/O Module |
|---|---|
| Interface: | Ethernet RJ-45 10/100 Base-Tx |
| Protocol: | Modbus TCP, Modbus UDP, MQTT |
| Digital inputs: | 2 |
| Relay outputs: | 1 |
| Ports: | 1 |
| Isolation: | 3750 Vrms (DI), 3000 Vrms (relay) |
| Power input: | +12 to +48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| Software | |
|---|---|
| Built-in Web Server | Yes |
| CPU Module | |
| CPU | 32-bit MCU |
| Watchdog Timer | Module, Communication (Programmable) |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| ESD (IEC 61000-4-2) | ±4 kV Contact for Each Terminal ±8 kV Air for Random Point |
| LED Indicators | |
| Status | Run, Ethernet |
| Digital Input/Counter | |
| Channels | 2 |
| Type | Dry Contact |
| Sink/Source (NPN/PNP) | Source |
| ON Voltage Level | Close to GND |
| OFF Voltage Level | Open |
| Max. Counts | 4,294,967,295 (32-bit) |
| Frequency | 3.5 kHz (without filter) |
| Min. Pulse Width | 0.15 ms |
| Effective Distance | 500m (max.) |
| Isolation | 3750 Vrms |
| Relay Output | |
| Channels | 1 |
| Type | Power Relay, Form A (SPST N.O.) |
| Contact Rating | 5.0 A/channel at 25°C |
| Operate Time | 6 ms |
| Release Time | 3 ms |
| Electrical Endurance | 5 A 250 VAC 30,000 ops (10 ops/minute) at 75 °C 5 A 30 VDC 70,000 ops (10 ops/minute) at 75 °C 5 A 250 VAC/30 VDC 6,000 ops 3 A 250 VAC/30 VDC 100,000 ops |
| Mechanical Endurance | 20,000,000 ops. At no load (300 ops./minute) |
| Isolation | 3000 Vrms |
| Ethernet | |
| Ports | 1 x RJ-45, 10/100 Base-Tx |
| Access Control | Password and IP Filter |
| Protocol | Modbus TCP, Modbus UDP, and MQTT |
| Power | |
| Reverse Polarity Protection | Yes |
| Consumption | 1.0 W |
| Powered from Terminal Block | +12 to +48 VDC |
| Mechanical | |
| Dimensions (mm) | 52 x 95 x 27 (W x L x H) |
| Installation | DIN-Rail mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 to 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.