I-7013 1-ch RTD Input Module, DCON Protocol, Pt100/Pt1000/Ni120
1-channel RTD input module for Pt100, Pt1000 and Ni120 sensors, with 2/3/4-wire connections, open wire detection and RS-485 DCON communication.
- Single RTD input for Pt100, Pt1000 and Ni120 sensors
- 2/3/4-wire RTD connections with open wire detection
- Lead resistance elimination for 3- and 4-wire connections
- 16-bit resolution, ±0.05% of FSR accuracy, 10 Hz sampling rate
- 3000 VDC intra-module isolation
- RS-485 port with DCON protocol, 1200 ~ 115200 bps
199,00 € per piece
| 1–9 pcs | 199,00 € | |
|---|---|---|
| 10–30 pcs | 193,00 € | −3 % |
| 31+ pcs | 189,00 € | −5 % |
Informacje dot. produktu "I-7013 1-ch RTD Input Module, DCON Protocol, Pt100/Pt1000/Ni120"
The I-7013 CR is a single-channel RTD input module for measuring temperature directly from Pt100, Pt1000 and Ni120 sensors. It supports 2-, 3- and 4-wire sensor connections, and lead resistance elimination is available for 3- and 4-wire wiring, which helps keep measurement errors from cable resistance under control.
Each channel offers 16-bit resolution, ±0.05% of FSR accuracy and a 10 Hz sampling rate. Open wire detection flags broken sensor connections, and the module provides 3000 VDC intra-module isolation between its circuits.
Communication is via one RS-485 port using the DCON protocol, with baud rates from 1200 to 115200 bps and selectable data formats. The module is designed for DIN-rail mounting and operates from +10 to +30 VDC over an operating range of -25 to +75 °C.
Applications
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
| Product type: | RTD Input Module |
|---|---|
| Interface: | RS-485 |
| Protocol: | DCON |
| Analog inputs: | 1 |
| Ports: | 1 |
| Isolation: | 3000 VDC |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Module, Communication (Programmable) |
| Isolation | |
| Intra-module Isolation | 3000 VDC |
| EMS Protection | |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| ESD (IEC 61000-4-2) | ±2 kV Contact for Each Terminal |
| Surge (IEC 61000-4-5) | ±0.5 kV for Power Line |
| LED Indicators | |
| Status | 1 x Power and Communication |
| Analog Input | |
| Channels | 1 |
| Type | RTD |
| Sensor Type | Pt100, Pt1000, Ni120 |
| Resistance Measurement | 3.2 kΩ max. |
| Resolution | 16-bit |
| Accuracy | ±0.05% of FSR |
| Sampling Rate | 10 Hz |
| Overvoltage Protection | ±5 VDC |
| Open Wire Detection | Yes |
| 3-wire RTD Lead Resistance Elimination | Yes |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Data Format | (N, 8, 1), (N, 8, 2), (E, 8, 1), or (O, 8, 1) |
| Protocol | DCON |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +30 VDC |
| Consumption | 0.7 W |
| Mechanical | |
| Dimensions (mm) | 72 x 123 x 35 (W x L x H) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +85 °C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.
Downloads
Zaloguj się