CL-201-WF CO/Temp/Humidity/Dew Point Data Logger with Wi-Fi and PoE
Wi-Fi, Ethernet and RS-485 data logger module for CO, temperature, humidity and dew point, storing up to 450,000 time-stamped records with PoE or DC power.
- Measures CO (0 to 1000 ppm, electrochemical), temperature, humidity and dew point
- Stores up to 450,000 time-stamped records with a real-time clock
- RS-485, Ethernet and Wi-Fi (IEEE 802.11 b/g/n) interfaces
- Modbus RTU and DCON on RS-485, Modbus TCP on Ethernet and Wi-Fi, MQTT on Ethernet
- Relay output: 1 x Form A, SPST, 30 VDC or 250 VAC @ 16 A
- Redundant PoE (IEEE 802.3af, Class 1) and +12 ~ +48 VDC power inputs
329,00 € per piece
| 1–9 pcs | 329,00 € | |
|---|---|---|
| 10–30 pcs | 319,00 € | −3 % |
| 31+ pcs | 312,00 € | −5 % |
Prekės informacija "CL-201-WF CO/Temp/Humidity/Dew Point Data Logger with Wi-Fi and PoE"
The CL-201-WF CR is a data logger module for monitoring carbon monoxide alongside temperature, humidity and dew point. It records each measurement with date and time stamps, so engineers can review trends or export logs for analysis. A relay output can be used for alarm signalling or to control external IAQ equipment.
Communication is available over RS-485, Ethernet and Wi-Fi, which makes the module straightforward to add to an existing HMI, SCADA or distributed control system. Supported protocols are DCON and Modbus RTU on RS-485, Modbus TCP on Ethernet and Wi-Fi, and MQTT on Ethernet. The module supports infrastructure and limited AP modes for wireless networks.
- Records CO, temperature, humidity and dew point with date and time stamps
- Holds up to 450,000 records for download
- Redundant power inputs: PoE (IEEE 802.3af, Class 1) and +12 ~ +48 VDC
- Ceiling or wall mounting
Applications
- Transportation of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Blood stations and pharmacies
- Building and energy management
- Warehouse management
- Museums, archives and galleries
- Indoor or underground parking lot air quality monitoring
| Product type: | Data Logger |
|---|---|
| Interface: | Ethernet, RS-485, Wi-Fi |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | 1 |
| Ports: | 2 |
| PoE: | Yes (IEEE 802.3af, Class 1) |
| Power input: | PoE or +12 ~ +48 VDC |
| Operating temperature: | 0 ~ 50 °C |
| Mounting: | Ceiling/Wall |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module (2.3 seconds), Communication (Programmable) |
| System | |
| Security | IP filter (whitelist) and Password (web) |
| Alarm | CO/RH/Temperature |
| Real Time Clock | Yes |
| Data Logger | Yes, up to 450,000 records |
| Temperature Measurement | |
| Range | -10 ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Humidity Measurement | |
| Range | 0 ~ 100% RH, Non-condensing |
| Resolution | 0.1% RH, Non-condensing |
| Accuracy | ±5% RH, Non-condensing |
| CO Measurement | |
| Range | 0 to 1000 ppm (Electrochemical) |
| Resolution | 1 ppm |
| Accuracy | ±5% of measured value |
| Response Time | 30 seconds |
| Warm-up Time | 5 minutes |
| Wi-Fi | |
| Transmission Distance (LoS) | 50 meters (LOS) |
| Standard Supported | IEEE 802.11 b/g/n |
| RX Sensitivity | -95.7 dBm @ 1 DSSS, -74.0 dBm @ 54 OFDM |
| Output Power | 18 dBm @ 1 DSSS, 14.5 dBm @ 54 OFDM |
| Mode | Infrastructure & Limited AP |
| Encryption | WEP, WPA and WPA2 |
| Antenna | 1 dBi (PCB Antenna) |
| Relay Output | |
| Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet |
| Baud Rate | 1200 ~ 115200 bps |
| Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP (Ethernet, Wi-Fi) MQTT (Ethernet) |
| Power | |
| Consumption | Non-PoE: 1.6 W (Max.) PoE: 1.7 W (Max.) |
| Powered from Terminal Block | +12 ~ +48 VDC |
| Mechanical | |
| Dimensions (mm) | Ø 150 x 53 (Ø x H) |
| Installation | Ceiling Mounting/Wall Mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ 50°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.
Downloads