DN-848VI-80V 8-Channel ±80 Vpp Voltage Attenuator, Channel Isolation
8-channel AC/DC voltage attenuator that scales ±80 Vpp inputs down to ±10 Vpp for standard analogue input modules, with 3000 VDC channel-to-channel isolation.
- Attenuates ±80 Vpp AC/DC inputs to a linear ±10 Vpp output
- 8 independent channels
- 3000 VDC channel-to-channel isolation and 3000 VDC intra-module isolation
- Input impedance above 1 MΩ
- 30 kHz bandwidth
- Accuracy of 1% of FSR
528,00 € per piece
| 1–9 pcs | 528,00 € | |
|---|---|---|
| 10–30 pcs | 512,00 € | −3 % |
| 31+ pcs | 502,00 € | −5 % |
Info sui prodotti "DN-848VI-80V 8-Channel ±80 Vpp Voltage Attenuator, Channel Isolation"
The DN-848VI-80V CR is an 8-channel voltage attenuator that lets standard low-voltage analogue input modules measure higher-voltage AC or DC signals. Each channel accepts up to ±80 Vpp and delivers a linearly attenuated output of ±10 Vpp, so the signal stays within the input range of the connected module.
Channel-to-channel isolation of 3000 VDC keeps noise from one input from interfering with the others and helps protect outputs from input-side disturbances. Input impedance above 1 MΩ limits loading on the measured source. The module suits DIN-rail installation in a plastic housing and runs from a +10 to +30 VDC supply.
It is designed to be used with analogue input modules such as the I-7017 and I-87017 to measure high voltage. The unit is rated for operation from -25 to +75 °C and carries CE, UKCA, RoHS and WEEE marks.
Applications
- High-voltage measurement with low-voltage analogue input modules
- Measuring AC or DC voltages with I-7017 or I-87017 analogue input modules
- Industrial data acquisition where input isolation is required
| Product type: | Voltage Attenuator |
|---|---|
| Analog inputs: | 8 |
| Analog outputs: | 8 |
| Isolation: | 3000 VDC channel-to-channel |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
| Housing: | Plastic |
Specifications
| EMS Protection | |
|---|---|
| ESD (IEC 61000-4-2) | ±4 kV contact for power line, input and output channels, ±8 kV air for random point |
| Surge (IEC 61000-4-5) | ±3 kV for power liner |
| Analog Input | |
| Channels | 3 : DN-843V-600V, DN-843VI-600V 8 : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Type | AC/DC Voltage |
| Range | ±10 ~ ±800 Vpp |
| Accuracy | 1% of FSR |
| Bandwidth | 30 KHz : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V 100 KHz : DN-843V-600V, DN-843VI-600V |
| Input Impedance | >1 MΩ |
| Channel-to-Channel Isolation | 3000 VDC (except DN-843V-600V) |
| Intra-module Isolation | 3000 VDC (except DN-843V-600V) |
| Analog Output | |
| Channels | 3 : DN-843V-600V, DN-843VI-600V 8 : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Type | AC/DC Voltage |
| Range | ±10 Vpp |
| Power | |
| Input Range | +10 ~ +30 VDC |
| Consumption | 0.56 W : DN-843V-600V 3.84 W : DN-843VI-600V 9.2 W : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 174 x 122 x 25 (W x L x D) : DN-843V-600V, DN-843VI-600V 174 x 122 x 33 (W x L x D) : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +75 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.