Preskoči na glavni sadržaj Preskoči na pretraživanje Preskoči na glavnu navigaciju

PM-3112-160 Single-Phase Power Meter, Modbus RTU, 100 A CT

Informacije o proizvodu "PM-3112-160 Single-Phase Power Meter, Modbus RTU, 100 A CT"

The PM-3112-160 CR is a compact single-phase power meter that reports true RMS voltage, current, active, apparent and reactive power and energy, power factor and frequency in real time. It suits engineers who need accurate consumption data from a monitored load without breaking the circuit, thanks to its clip-on current transformer.

This variant includes two 100 A CTs with a 16 mm inside diameter and 1.8 m wire leads, covering an input current range of 0.1 A to 100 A. Two independent loops support single-phase 1P2W energy analysis, with an input voltage range of 10 ~ 300 V and active power accuracy better than 0.5% (PF=1).

Two Form A power relay outputs, rated 5 A @ 250 VAC or 5 A @ 30 VDC, can drive sirens or lights for alarm signalling. Communication is via a single RS-485 port running Modbus RTU, with 3000 VDC isolation. The DIN-rail mounted plastic housing is designed for switchgear and distribution panels.

Applications

  • Generator monitoring
  • Switchgear distribution systems
  • Energy management
Product type: Power meter
Interface: RS-485
Protocol: Modbus RTU
Relay outputs: 2
Ports: 1
Isolation: 3000 VDC
Power input: +12 ~ 48 VDC
Operating temperature: -20 ~ +70 °C
Mounting: DIN-rail
Housing: Plastic

Specifications

AC Power Measurement
Wiring1P2W-1CT
Loops1-phase: 2
Input Voltage10 ~ 300 V
Input CurrentPM-3112-100: CTØ10 mm (0.05 A ~ 60 A)
PM-3112-100P: CTØ10 mm (0.05 A ~ 60 A)
PM-3112-160: CTØ16 mm (0.1 A ~ 100 A)
PM-3112-160P: CTØ16 mm (0.1 A ~ 100 A)
PM-3112-240: CTØ24 mm (0.15 A ~ 200 A)
PM-3112-240P: CTØ24 mm (0.15 A ~ 200 A)
Input Frequency50/60 Hz
W AccuracyBetter than 0.5% (PF=1)
Power Parameter MeasurementTrue RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate1 Second
Relay Output
Channels2
TypePower Relay
Contact RatingForm A:
5 A @ 250 VAC
5 A @ 30 VDC
COM Ports
Ports1 x RS-485
Baud Rate9600, 19200 (default), 38400, 115200; DIP Switch Selectable
Data FormatN,8,1 (default); N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
ProtocolModbus RTU
Isolation3000 VDC
Power
Input Range+12 ~ 48 VDC
Consumption2W
Mechanical
CasingPlastic
Dimensions (mm)33 x 127 x 100 (W x L x H)
InstallationDIN-Rail Mounting
Environment
Operating Temperature-20 ~ +70 °C
Storage Temperature-25 ~ +80 °C
Humidity10 ~ 90% RH, Non-condensing

Specifications as published by the manufacturer. Subject to change.

0 od 0 recenzija

Prosječna ocjena 0 od 5 zvjezdica

Ostavite recenziju!

Podijelite svoja iskustva s drugim kupcima.