PM-2133D-RCT2000P 3-Phase Power Meter, 2000A Rogowski Coil, Modbus RTU
Three-phase Modbus RTU power meter with an 8-digit LED display and a 2000A Rogowski Coil CT (105 mm inside diameter) for high-current energy monitoring.
- Rogowski Coil CT with 105 mm inside diameter, measuring 5 A ~ 2000 A per phase
- Bi-directional energy measurement with true RMS voltage, current and power readings
- Energy analysis for 3P4W, 3P3W, 1P3W and 1P2W wiring configurations
- Active power accuracy better than 2% at PF=1 with input current above 200 A
- Modbus RTU over one RS-485 port, baud rates 9600 to 115200
- 8-digit LED display and total harmonic distortion (THD) measurement
1.227,00 € per piece
| 1–9 pcs | 1.227,00 € | |
|---|---|---|
| 10–30 pcs | 1.190,00 € | −3 % |
| 31+ pcs | 1.166,00 € | −5 % |
Informacije o proizvodu "PM-2133D-RCT2000P 3-Phase Power Meter, 2000A Rogowski Coil, Modbus RTU"
PM-2133D-RCT2000P CR is a three-phase power meter for measuring bi-directional energy on feeders carrying up to 2000 A. Its flexible Rogowski Coil current sensor, with a 105 mm inside diameter and a 4 m wire lead, suits large conductors and installations where space around the busbar or cable is limited.
The meter provides true RMS voltage, current, active, reactive and apparent power and energy, power factor, frequency and total harmonic distortion. It supports 3P4W, 3P3W, 1P3W and 1P2W energy analysis, with a voltage input range of 10 ~ 500 V. Readings are shown on an 8-digit LED display and made available over a single RS-485 port using Modbus RTU.
Current measurement covers 5 A ~ 2000 A. Per the source, active power accuracy is better than 2% at PF=1 when the input current exceeds 200 A. The unit has 3000 VDC isolation on the serial port, a +85 ~ +264 VAC power input, and a panel-mount plastic housing measuring 110 x 115 x 50 mm.
Applications
- Generator monitoring
- Switchgear distribution systems
- Energy management
| Product type: | Power meter |
|---|---|
| Interface: | RS-485 |
| Protocol: | Modbus RTU |
| Ports: | 1 |
| Isolation: | 3000 VDC |
| Power input: | +85 ~ +264 VAC |
| Operating temperature: | -20 ~ +70 °C |
| Mounting: | Panel |
Specifications
| AC Power Measurement | |
|---|---|
| Wiring | 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT |
| Loops | 3-phase: 1; 1-phase: 3 @ 1P2W-1CT, 1 @ 1P3W-2CT |
| Input Voltage | 10 ~ 500 V |
| Input Current | PM-2133D-RCT500P: CTØ55 mm (5 A ~ 500 A) PM-2133D-RCT1000P: CTØ80 mm (5 A ~ 1000 A) PM-2133D-RCT2000P: CTØ105 mm (5 A ~ 2000 A) PM-2133D-RCT4000P: CTØ185 mm (5 A ~ 4000 A) |
| Input Frequency | 50 Hz (Range 45 ~ 55 Hz)/60 Hz (Range 55 ~ 65 Hz) |
| W Accuracy | Better than 2% (PF=1) Condition: Input current > 50A; (For -500P, -1000P) Input current > 200A; (For -2000P, -4000P) |
| Power Parameter Measurement | True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency (45 ~ 65 Hz) |
| Data Update Rate | 1 Second |
| LED Display | Yes, 8-digit |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 9600, 19200 (default), 38400, 115200 |
| Data Format | N,8,1; N,8,2; E,8,1; E,8,2; O,8,1; O,8,2 |
| Protocol | Modbus RTU |
| Isolation | 3000 VDC |
| Power | |
| Input Range | +85 ~ +264 VAC (277 VAC available) |
| Consumption | 6 W |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 110 x 115 x 50 (W x L x H) |
| Installation | Panel Mounting |
| Environment | |
| Operating Temperature | -20 ~ +70 °C |
| Storage Temperature | -25 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.