Preskoči na glavni sadržaj Preskoči na pretraživanje Preskoči na glavnu navigaciju

CL-210-E PM2.5, Temperature and Humidity Data Logger Module

Informacije o proizvodu "CL-210-E PM2.5, Temperature and Humidity Data Logger Module"

CL-210-E CR is a data logger module that measures PM2.5, temperature, humidity and dew point, and records each reading with a date and time stamp. Up to 450,000 records can be stored and downloaded, which suits monitoring projects where a complete history of air quality and climate conditions is needed.

The module offers RS-485 and Ethernet connectivity, with PoE support on the Ethernet port. It speaks DCON, Modbus RTU, Modbus TCP and MQTT, so it can be connected to existing HMI, SCADA or IoT platforms in distributed control systems. A single relay output (Form A, SPST) can be used for alarm signalling or for controlling an indoor air quality device.

Configuration, real-time monitoring and log download are handled by the iAir Utility, with iOS and Android apps and web browser access available on the same local network. Log data can be exported to CSV for analysis in standard spreadsheet or industry software.

Applications

  • Transportation of food or pharmaceuticals
  • Food and beverage industry (HACCP)
  • Blood stations and pharmacies
  • Building and energy management
  • Warehouse management
  • Museums, archives and galleries
  • Indoor or underground parking lot air quality monitoring
Product type: Data logger module
Interface: Ethernet, RS-485
Protocol: DCON, Modbus RTU, Modbus TCP, MQTT
Relay outputs: 1 (Form A, SPST)
Ports: 2
PoE: Yes
Power input: +12 ~ +48 VDC
Operating temperature: 0 ~ 50 °C
Mounting: Ceiling/Wall

Specifications

System
AlarmPM2.5/RH/Temperature
Real Time ClockYes
Data LoggerYes, up to 450,000 records
Temperature Measurement
Range-10 ~ +50°C
Resolution0.1°C
Accuracy±0.6°C
Humidity Measurement
Range0 ~ 100% RH, Non-condensing
Resolution0.1% RH, Non-condensing
Accuracy±5% RH, Non-condensing
Dew Point
RangeCalculated using temperature and relative humidity
Resolution0.1°C
PM2.5 Measurement
Range0 ~ 400 μg/m3
Resolution1μg/m3
Response Time<= 1 min.
Relay Output
Channels1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Ethernet
Ports10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
COM Ports
Ports1 x RS-485
1 x Ethernet
ProtocolDCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Power
ConsumptionNon-PoE: 2.5 W (Max.)
PoE: 2.65 W (Max.)
Powered from Terminal Block+12 ~ +48 VDC
Mechanical
Dimensions (mm)Ø 150 x 53 (Ø x H)
InstallationCeiling Mounting/Wall Mounting
Ingress Protection RatingIP20
Environment
Operating Temperature0 ~ 50°C
Storage Temperature-30 ~ +75°C
Humidity10 ~ 90% RH, Non-condensing

Specifications as published by the manufacturer. Subject to change.

0 od 0 recenzija

Prosječna ocjena 0 od 5 zvjezdica

Ostavite recenziju!

Podijelite svoja iskustva s drugim kupcima.