WISE-5800-MTCP Web-Configured I/O Module for Modbus TCP Devices
Browser-configured WISE controller that runs IF-THEN-ELSE logic without programming, expands I/O via XW-Board and connects up to 7 Modbus TCP slave devices.
- IF-THEN-ELSE logic with up to 36 rules, built in the browser without programming
- XW-Board I/O expansion for digital and analogue input and output functions
- Connects up to 7 Modbus TCP slave devices, with Active I/O (Modbus TCP Master) mode
- Modbus TCP and Modbus RTU support for seamless SCADA integration
- Data logger on microSD card, triggered by events or by time period, with email or FTP file transfer
- 12 timers, 12 schedules, 12 recipes and 48 internal registers
This item is quoted per order. Send us your quantity and we reply with price and delivery time.
Request a quote
Ei enää saatavilla
Tuotetiedot "WISE-5800-MTCP Web-Configured I/O Module for Modbus TCP Devices"
WISE-5800-MTCP is a remote logic control and monitoring unit from the WISE series that is configured entirely through a web browser, so no extra software tool or programming is needed. Control logic is built as IF-THEN-ELSE rules, with up to 36 rules supported, which keeps commissioning quick for system integrators.
The module extends its I/O through the XW-Board expansion bus, covering digital and analogue input and output functions, and can also poll up to 7 Modbus TCP slave devices. It supports Modbus TCP and Modbus RTU for integration with SCADA software, alongside timers, schedules, recipes and internal registers.
An onboard data logger records I/O values to a microSD card on an event trigger or at regular intervals, and the data files can be sent by non-SSL email or FTP. The unit is powered from 12 ~ 48 VDC with reverse polarity protection and redundant power inputs, and mounts on a DIN rail.
Applications
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote diagnosis and Testing Equipment
| Product type: | IIoT I/O Module |
|---|---|
| Interface: | Ethernet, RS-232, RS-485 |
| Protocol: | Modbus RTU, Modbus TCP |
| Ports: | 1 Ethernet, 2 serial |
| Isolation: | Non-isolated serial ports |
| Power input: | 12 ~ 48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
Specifications
| Software | |
|---|---|
| Protocol | • Modbus TCP & Modbus RTU • FTP Client • CGI Command (Sending) • Active I/O (Modbus TCP Master) |
| Function | • Web Interface for Configuration • IF-THEN-ELSE Logic operation (36 rule supported) • I/O channel monitoring and control • Timer operation (12 set supported) • Schedule operation (12 set supported) • Data Logger operation (1 set supported) • Internal Register operation (48 set supported) • Recipe operation (12 set supported) • non-SSL Email sending function • SNTP Time Synchronization |
| CPU Module | |
| CPU | 16-bit CPU (80 MHz) |
| Storage Expansion | Support 1G/2G/4G/8G/16G/32G microSD card |
| LED Indicators | |
| Status | 1 x System Status 1 x MicroSD Card Status 1 x Ethernet Link Status |
| I/O Expansion | |
| I/O Type | XW-board |
| Remote Module Support | Modbus TCP Slave Module |
| Ethernet | |
| Ports | RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
| COM Ports | |
| Ports | COM 1: RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max. COM 2: RS-485 (Data+, Data-) with internal self-tuner ASIC; non-isolated, Speed: 115200 bps max. (Reserved) |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | 12 ~ 48 VDC |
| Redundant Power Inputs | Yes |
| Consumption | 2.0 W |
| Mechanical | |
| Dimensions (mm) | 91 × 123 × 52 (W x H x D) |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.