ECAN-240 Modbus TCP to 2-Port CAN Bus Gateway
Modbus TCP to 2-port CAN bus gateway for linking two CAN networks to Ethernet, with isolated CAN interfaces and DIN-rail mounting.
- Modbus TCP server gateway between Ethernet and two CAN bus networks
- Two CAN interfaces on 9-pin D-sub connectors, compliant with ISO 11898-2
- Supports CAN 2.0A and CAN 2.0B with baud rates of 10 k ~ 1M bps set by rotary switches
- Built-in 120 ohm terminal resistor, enabled or disabled by DIP switch
- 3000 VDC DC-to-DC and 2500 Vrms photo-coupler isolation on the CAN side
- Pair connection between CAN networks over TCP or UDP
380,00 € per piece
| 1–9 pcs | 380,00 € | |
|---|---|---|
| 10–30 pcs | 369,00 € | −3 % |
| 31+ pcs | 361,00 € | −5 % |
Tuotetiedot "ECAN-240 Modbus TCP to 2-Port CAN Bus Gateway"
ECAN-240 CR is a Modbus TCP to 2-port CAN bus gateway. It connects two CAN bus networks to an Ethernet network, so CAN devices can be reached from Modbus TCP clients and the two CAN segments can exchange data through the module.
Each of the two CAN interfaces follows ISO 11898-2 and supports CAN 2.0A and CAN 2.0B frames, with baud rates from 10 k to 1M bps set by rotary switches. A built-in 120 ohm terminal resistor is enabled or disabled with a DIP switch. The CAN ports are isolated, rated at 3000 VDC for DC-to-DC and 2500 Vrms for the photo-coupler stage.
Beyond Modbus TCP server operation, the gateway offers pair connection between CAN networks over TCP or UDP, and a transparent mode in which TCP (port 10003) or UDP (port 57540) packets carry CAN frames for custom software. The metal housing is rated for -25 ~ +75 °C operation and mounts on a DIN rail.
Applications
- Integrating CAN devices into Modbus TCP industrial networks
- Linking two CAN bus segments across Ethernet via pair connection
- Custom TCP or UDP applications that access CAN frames directly
| Product type: | CAN Bus Gateway |
|---|---|
| Interface: | CAN, Ethernet |
| Protocol: | Modbus TCP |
| Ports: | 1 Ethernet, 2 CAN |
| Isolation: | 3000 VDC / 2500 Vrms |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
| Housing: | Metal |
Specifications
| LED Indicators | |
|---|---|
| Status | 1 x Power 6 x CAN status |
| Ethernet | |
| Ports | 1 x RJ-45, 10/100Base-T(X) |
| Protocol | Modbus TCP Server, TCP, UDP, HTTP |
| Socket Connections | 8 for TCP, 1 for UDP |
| CAN | |
| Ports | 2 |
| Specification | ISO 11898-2 CAN 2.0A and CAN 2.0B |
| Baud Rate | 10 k ~ 1M bps |
| Isolation | 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple |
| Terminal Resistor | Built-in 120 ohm terminal resistor, enabled/disabled via DIP-Switch |
| Filter | Yes |
| Power | |
| Input Range | +10 VDC ~ +30 VDC |
| Consumption | 2 W |
| Mechanical | |
| Casing | Metal |
| Dimensions (mm) | 106.8 x 146.8 x 25.9 (W x L x H) |
| Installation | DIN-Rail |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.
Downloads