EC2-TC16 EtherCAT Slave I/O Module, 16-ch Thermocouple Input
EtherCAT slave module with 16 thermocouple inputs, 16-bit resolution, 100 Hz per-channel sampling and open wire detection, for daisy-chained EtherCAT networks.
- 16 thermocouple input channels with 16-bit resolution
- Supports Type J, K, T, E, R, S, B, N, C, L, M and LDIN43710 thermocouples
- 100 Hz sampling per channel with individual channel configuration and open wire detection
- Automatic cold-junction compensation on all channels
- Two RJ-45 EtherCAT ports for daisy-chain wiring, up to 100 m between stations
- Distributed clocks and 100 us cycle time
784,00 € per piece
| 1–9 pcs | 784,00 € | |
|---|---|---|
| 10–30 pcs | 760,00 € | −3 % |
| 31+ pcs | 745,00 € | −5 % |
Tuotetiedot "EC2-TC16 EtherCAT Slave I/O Module, 16-ch Thermocouple Input"
The EC2-TC16 is an EtherCAT slave I/O module that brings 16 thermocouple input channels to an EtherCAT network. Each channel samples at 100 Hz and reports open wire conditions, so sensor faults can be identified at channel level.
Each channel can be configured individually and accepts a wide choice of thermocouple types, including J, K, T, E, R, S, B, N, C, L, M and LDIN43710. Automatic cold-junction compensation is applied to all channels, which removes the need for external reference handling in most temperature measurement set-ups.
Two RJ-45 EtherCAT ports allow stations to be daisy-chained, with up to 100 m between stations over 100BASE-TX. Distributed clocks and a 100 us cycle time suit synchronised control, and the metal, IP40 housing mounts on a DIN rail or on a wall.
Applications
- Temperature measurement with thermocouple sensors in EtherCAT-based automation systems
- Distributed temperature monitoring with daisy-chained slave stations
| Product type: | Slave I/O Module |
|---|---|
| Interface: | EtherCAT |
| Protocol: | EtherCAT |
| Analog inputs: | 16 |
| Ports: | 2 x RJ-45 |
| Power input: | +24 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail / wall |
| Housing: | Metal |
Specifications
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | Signal: 1 KV Class B; Power: 1 KV Class B |
| ESD (IEC 61000-4-2) | ±4 kV Contact for Each Terminal |
| Surge (IEC 61000-4-5) | ± 1 kV Class A |
| Analog Input | |
| Channels | 16 |
| Type | Thermocouple (J, K, T, E, R, S, B, N, C, L, M, LDIN43710) |
| Resolution | 16-bit |
| Accuracy | ±0.1 % of FSR ( 25℃ ) |
| Sampling Rate | 100 Hz ( per channel ) |
| Overvoltage Protection | 30 VDC |
| Individual Channel Configuration | Yes |
| Open Wire Detection | Yes |
| EtherCAT | |
| Ports | EtherCAT, 2 X RJ45 |
| Node ID | Up to 256 |
| Distance Between Stations | Max. 100 m (100 Base-Tx) |
| Data Transfer Medium | Ethernet/EtherCAT cable (min. CAT5), shielded |
| Cycle Time | 100 us |
| Distributed Clocks | Yes |
| Power | |
| Input Range | +24 VDC |
| Consumption | 1.60 W |
| Mechanical | |
| Casing | Metal with IP40 |
| Dimensions (mm) | 83 x 122 x 65 (W x L x D) |
| Installation | DIN-Rail or Wall Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75°C |
| Storage Temperature | -30 ~ +80°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.