Saltar al contenido principal Saltar a la búsqueda Saltar a la navegación principal

HRT-310-UTA Modbus RTU/ASCII to HART Gateway, -40 ℃ Application

Información sobre el producto "HRT-310-UTA Modbus RTU/ASCII to HART Gateway, -40 ℃ Application"

HRT-310-UTA CR is a HART master gateway that bridges serial HART field devices and Modbus networks. The Modbus master accesses HART devices through the gateway, so transmitters, actuators and similar instruments appear as Modbus slaves to an HMI, SCADA system or PLC. Configuration and HART device diagnosis are handled with the HG_Tool software utility.

The gateway supports point-to-point and multi-drop HART topologies with up to 15 HART devices, using short and long frames and burst mode. Two HART masters can be allowed, and long frame addresses are acquired automatically. Modbus RTU and Modbus ASCII are both supported in Modbus slave mode over RS-232, RS-422 or RS-485.

This CR variant is intended for -40 ℃ applications, with an operating range of -40 ~ +75 °C. It is designed for DIN-rail mounting in an upright orientation and runs from an unregulated +10 ~ +30 VDC supply.

Applications

  • Industrial automation
  • Factory automation
  • Process automation
  • Integrating HART flow meters and field transmitters into HMI or SCADA systems over Modbus
Product type: Gateway
Interface: RS-232 / RS-422 / RS-485
Protocol: Modbus RTU / Modbus ASCII
Isolation: UL1577
Power input: +10 ~ +30 VDC
Operating temperature: -40 ~ +75 °C
Mounting: DIN-rail

Specifications

COM Ports
PortsRS-232(3 wires) / RS-422 / RS-485
Baud Rate1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
ProtocolModbus RTU / Modbus ASCII
HART
Ports1
Device2-wired or 4-wired HART devices
TopologyPoint to Point or Multi-Drop
DataOnly Digital Data
Frame TypeShort and Long Frame
Burst ModeSupported
Max. HART Device15
Loop Resistor250 Ω (1W) by Dip-Switch
IsolationUL1577 Spec.
Protocol2-pin screwed terminal block
Loop PowerYes (module provides +30V output)
Power
Reverse Polarity ProtectionPower reverse polarity protection, Over-voltage brown-out protection
Input RangeUnregulated +10 ~ +30 VDC
Consumption3.5W (Max.)
Mechanical
Dimensions (mm)25 x 116 x 120 (W x L x H)
InstallationDIN-Rail (Upright)
Environment
Operating Temperature-40 ~ +75 °C
Storage Temperature-40 ~ +80 °C
Humidity10% ~ 90% RH, Non-condensing

Specifications as published by the manufacturer. Subject to change.