ACS-20W-MRTU No-touch Infrared Sensor Switch, RS-485 Modbus RTU
No-touch infrared sensor switch with an RS-485 Modbus RTU slave interface and a Form C relay output, for hands-free door opening in access control systems.
- Palm induction with an induction distance of 1 ~ 12 cm
- Modbus RTU slave interface over RS-485, baud rates 9600 to 115200 bps
- Adjustable relay hold time of 0.5 ~ 20 sec
- Form C relay with N.C. and N.O. output, rated 2A@30VDC, 0.5A@120VAC, 0.25A@240VAC
- Sensing/Standby, Lock and Toggle Switch operating modes, with 8 lockup periods each day
- Logs up to 1,600 switch action time records
82,00 € per piece
| 1–9 pcs | 82,00 € | |
|---|---|---|
| 10–30 pcs | 79,00 € | −4 % |
| 31+ pcs | 78,00 € | −5 % |
Πληροφορίες για το προϊόν "ACS-20W-MRTU No-touch Infrared Sensor Switch, RS-485 Modbus RTU"
ACS-20W-MRTU CR is a wall-mounted no-touch infrared sensor switch with a white cover. It lets people open a door by palm induction, so occupants do not need to touch a handle or button when entering or leaving a room or building. The induction distance and relay hold time are adjustable, and a double-colour indicator shows the switch status.
The switch has a Modbus RTU slave interface on RS-485, allowing an access control system to enable or disable it remotely and to read back its time-stamped induction records. Each entry or exit can be logged, with storage for 1,600 records. The single Form C relay provides both N.C. and N.O. contacts, and the switch can operate in Sensing/Standby, Lock or Toggle Switch mode, so it can also control other electronic equipment.
Typical sites include medical institutions, retail stores, food processing, industrial plants and offices, where reducing contact with door hardware helps limit the spread of germs.
Applications
- Touch-free door opening in access control systems
- Hygienic entry in medical institutions, retail stores and the food industry
- Switching other electronic devices in toggle mode
- Door access in industrial plants and offices
| Product type: | No-touch Infrared Sensor Switch |
|---|---|
| Interface: | RS-485 |
| Protocol: | Modbus RTU |
| Relay outputs: | 1 |
| Ports: | 1 |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | Wall mounting |
Specifications
| LED Indicators | |
|---|---|
| Status | Red (Standby); Blue (Sensing) |
| Infrared | |
| IR Output Channels | 1 |
| IR Remote Input | 1 |
| Relay Output | |
| Channels | 1 |
| Type | Form C |
| Contact Rating | 2A@30VDC, 0.5A@120VAC, 0.25A@240VAC |
| COM Ports | |
| Ports | RS-485 (DATA+, DATA-) |
| Baud Rate | 9600, 19200, 38400, 57600, 115200 bps |
| Protocol | Modbus RTU Slave |
| Power | |
| Input Range | +10~+30 VDC |
| Mechanical | |
| Dimensions (mm) | 75 x 119 x 24 (WxLxH) |
| Installation | Wall Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |