CL-210-WF PM2.5 Data Logger Module, RS-485/Ethernet/Wi-Fi
Data logger module for PM2.5, temperature, humidity and dew point, with RS-485, Ethernet and Wi-Fi interfaces, up to 450,000 timestamped records, and PoE or DC power.
- Measures PM2.5, temperature, humidity and dew point
- Stores up to 450,000 records with date and time stamps
- RS-485, Ethernet and Wi-Fi communication interfaces
- DCON, Modbus RTU/TCP and MQTT (Ethernet) protocol support
- Relay output for alarm or IAQ device control
- Redundant power inputs: PoE (IEEE 802.3af, Class 1) or +12 ~ +48 VDC
366,00 € per piece
| 1–9 pcs | 366,00 € | |
|---|---|---|
| 10–30 pcs | 355,00 € | −3 % |
| 31+ pcs | 348,00 € | −5 % |
Informace o výrobku "CL-210-WF PM2.5 Data Logger Module, RS-485/Ethernet/Wi-Fi"
The CL-210-WF CR is a data logger module for indoor air quality monitoring. It records PM2.5, temperature, humidity and dew point, stamping each record with date and time for up to 450,000 records, which suits long-term logging in monitored environments.
Communication is available over RS-485, Ethernet and Wi-Fi (IEEE 802.11 b/g/n). Protocol support covers DCON and Modbus RTU on RS-485, Modbus TCP on Ethernet and Wi-Fi, and MQTT on the Ethernet interface, so the module can be integrated into existing HMI or SCADA systems. A relay output can be used for alarm or IAQ device control.
Power can come from PoE (IEEE 802.3af, Class 1) or from a DC terminal block at +12 ~ +48 VDC. The module mounts on a ceiling or wall, and the included software utility, along with the iOS and Android apps, handles configuration and real-time monitoring.
Applications
- Transportation of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Blood stations and pharmacies
- Building and energy management
- Warehouse management
- Museums, archives and galleries
- Indoor or underground car park monitoring
| Product type: | Data logger module |
|---|---|
| Interface: | Ethernet, RS-485, Wi-Fi |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | 1 |
| Ports: | 1 x RS-485, 1 x Ethernet |
| PoE: | IEEE 802.3af, Class 1 |
| Power input: | PoE or +12 ~ +48 VDC |
| Operating temperature: | 0 ~ 50 °C |
| Mounting: | Ceiling / Wall |
Specifications
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module (2.3 seconds), Communication (Programmable) |
| System | |
| Security | IP filter (whitelist) and Password (web) |
| Alarm | PM2.5 |
| Real Time Clock | Yes |
| Data Logger | Yes, up to 450,000 records |
| Temperature Measurement | |
| Range | -10 ~ +50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.6°C |
| Humidity Measurement | |
| Range | 0 ~ 100% RH, Non-condensing |
| Resolution | 0.1% RH, Non-condensing |
| Accuracy | ±5% RH, Non-condensing |
| Dew Point | |
| Range | Calculated using temperature and relative humidity |
| Resolution | 0.1°C |
| PM2.5 Measurement | |
| Range | 0 ~ 400 μg/m3 |
| Resolution | 1μg/m3 |
| Response Time | <= 1 min. |
| Wi-Fi | |
| Transmission Distance (LoS) | 50 meters (LOS) |
| Standard Supported | IEEE 802.11 b/g/n |
| RX Sensitivity | -95.7 dBm @ 1 DSSS, -74.0 dBm @ 54 OFDM |
| Output Power | 18 dBm @ 1 DSSS, 14.5 dBm @ 54 OFDM |
| Mode | Infrastructure & Limited AP |
| Encryption | WEP, WPA and WPA2 |
| Antenna | 1 dBi (PCB Antenna) |
| Relay Output | |
| Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet |
| Baud Rate | 1200 ~ 115200 bps |
| Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP (Ethernet, Wi-Fi) MQTT (Ethernet) |
| Power | |
| Consumption | Non-PoE: 2.7 W (Max.) PoE: 2.8 W (Max.) |
| Powered from Terminal Block | +12 ~ +48 VDC |
| Mechanical | |
| Dimensions (mm) | Ø 150 x 53 (Ø x H) |
| Installation | Ceiling Mounting/Wall Mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ 50°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifications as published by the manufacturer. Subject to change.