PPDS-720-MTCP Serial-to-Ethernet Device Server, PoE, Modbus TCP Gateway
Programmable serial-to-Ethernet device server with one RS-232 and one RS-485 port, PoE powering and a Modbus TCP to RTU/ASCII gateway function for linking serial devices to Ethernet networks.
- Links RS-232 and RS-485 serial devices to a 10/100 Base-TX Ethernet network
- Modbus TCP to RTU/ASCII gateway for Modbus TCP SCADA and HMI communication
- VxComm utility maps built-in COM ports to virtual COM ports on Windows PCs
- Programmable Xserver structure with built-in MiniOS7 for custom Ethernet applications
- PoE powered under IEEE 802.3af, Class 1, or from +12 ~ 48 VDC terminal block
- Watchdog timer and +/-4 kV ESD protection on the serial port for harsh environments
208,00 € per piece
| 1–9 pcs | 208,00 € | |
|---|---|---|
| 10–30 pcs | 202,00 € | −3 % |
| 31+ pcs | 197,00 € | −5 % |
Информация за продукта "PPDS-720-MTCP Serial-to-Ethernet Device Server, PoE, Modbus TCP Gateway"
PPDS-720-MTCP is a programmable device server that brings serial devices onto an Ethernet network. It provides one RS-232 port and one RS-485 port, and the removable on-board terminal block simplifies wiring in industrial installations. Ordering code PPDS-720-MTCP CR includes a CA-0910 cable.
The unit can present its built-in COM ports as standard COM ports on a Windows PC using the VxComm utility, which supports 32/64-bit Windows 7 SP1, 10, 2012 and 2016. Its built-in MiniOS7 runs a programmable Xserver structure for custom Ethernet applications, and it works as a Modbus TCP to RTU/ASCII gateway for SCADA and HMI systems that communicate over Modbus TCP.
The device accepts power either from a PoE switch under IEEE 802.3af, Class 1, using a standard category 5 cable, or from a +12 ~ 48 VDC terminal block supply. It is a DIN-rail or wall-mounted unit rated for an operating temperature of -25 ~ +75 °C.
Applications
- Factory Automation
- Building Automation
- Home Automation
| Product type: | Serial-to-Ethernet device server |
|---|---|
| Interface: | 10/100 Base-TX Ethernet, RS-232, RS-485 |
| Protocol: | Modbus TCP |
| Ports: | 2 (1x RS-232, 1x RS-485) |
| PoE: | IEEE 802.3af, Class 1 |
| Power input: | +12 ~ 48 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail, Wall |
| Housing: | Plastic |
Specifications
| CPU Module | |
|---|---|
| CPU | 80186-80 MHz or compatible |
| EEPROM | 16 KB; Data retention: 40 years; 1,000,000 erase/write cycles |
| Flash | 512 KB; Erase unit is one sector (64 KB); 100,000 erase/write cycles |
| SRAM | 512 KB |
| Watchdog Timer | Yes |
| LED Indicators | |
| Status | 1 x Power |
| Ethernet | |
| Ports | 10/100 Base-TX, RJ-45 port (Auto-negotiating, auto MDI/MDI-X, LED indicator) |
| COM Ports | |
| Ports | 1 x 5-wire RS-232 1 x RS-485 |
| Baud Rate | 115200 bps Max. |
| Bias Resistor | Yes, 1 KΩ |
| Parity | None, Even, Odd, Mark, Space None parity is required when using 8 data bits and 2 stop bits on COM1/COM2. |
| Data Bit | 7, 8: for COM1 and COM2 |
| Stop Bit | 1, 2: for COM1 ~ COM2 |
| Node Address | 254 (max.) |
| Power | |
| Consumption | 2.2 W |
| Powered from PoE | IEEE 802.3af, Class 1 |
| Powered from Terminal Block | +12 ~ 48 VDC |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 72 mm x 35 mm x 112 mm (W x L x H) |
| Installation | DIN-Rail or Wall mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +80 °C |
| Humidity | 5 ~ 90% RH, non-condensing |
Specifications as published by the manufacturer. Subject to change.